Studies on measurement uncertainty and economy of dimensional computed tomography measurements on selected examples

被引:1
|
作者
Hiller, Jochen [1 ]
Sawczyn, Nikolas [2 ]
Imkamp, Dietrich [3 ]
Uhlmann, Eckart [2 ,4 ]
机构
[1] Tech Hsch Deggendorf, Fraunhofer Anwendungs Zentrum Comp Tomog Messtech, Fak Maschinenbau & Mechatron, Edlmairstr 9, D-94469 Deggendorf, Germany
[2] Tech Univ Berlin, Inst Werkzeugmaschinen & Fabrikbetrieb IWF, Pascalstr 8-9, D-10587 Berlin, Germany
[3] Carl Zeiss Ind Messtech GmbH, Carl Zeiss Str 22, D-73447 Oberkochen, Germany
[4] Fraunhofer Inst Prod Sanlagen & Konstrukt Tech IP, Pascalstr 8-9, D-10587 Berlin, Germany
关键词
Production measurement technology; conformity testing; computed tomography; measurement uncertainty; METROLOGY;
D O I
10.1515/teme-2016-0050
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Industrial computed tomography (CT) is increasingly being applied for non-destructive testing of components in process quality assurance. The advantage over tactile or optical measuring methods is in particular the possibility to measure both, outer as well as inner geometry features non-destructively. In this article, possibilities for increasing the economy of CT measurements by simultaneous tomographic scanning of several components in the CT measuring volume are being investigated by using selected components, and the measurement uncertainty for the individual scanning settings is determined experimentally.
引用
收藏
页码:336 / 347
页数:12
相关论文
共 50 条
  • [41] Determination of the measurement uncertainity of computed tomography measurements using a cylinder head as an example
    Bartscher, Markus
    Hilpert, Uwe
    Fiedler, Dirk
    TM-TECHNISCHES MESSEN, 2008, 75 (03) : 178 - 186
  • [42] Diagnostic Accuracy of Cone Beam Computed Tomography for Dimensional Linear Measurements in the Mandible
    Halperin-Sternfeld, Michal
    Machtei, Eli E.
    Horwitz, Jacob
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (03) : 593 - 599
  • [43] Effect of the number of projections on dimensional measurements with X-ray computed tomography
    Villarraga-Gomez, Herminso
    Smith, Stuart T.
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2020, 66 : 445 - 456
  • [44] Measurements of pelvic flexion angle using three-dimensional computed tomography
    Nishihara, S
    Sugano, N
    Nishii, T
    Ohzono, K
    Yoshikawa, H
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (411) : 140 - 151
  • [45] Three- Dimensional Computed Tomography Reconstruction Measurements of Acetabulum in Chinese Adults
    Ma, Hecheng
    Han, Yingying
    Yang, Qiwei
    Gong, Yubao
    Hao, Shuang
    Li, Youqiong
    Liu, Jianguo
    ANATOMICAL RECORD-ADVANCES IN INTEGRATIVE ANATOMY AND EVOLUTIONARY BIOLOGY, 2014, 297 (04): : 643 - 649
  • [46] Performance studies of four-dimensional cone beam computed tomography
    Qi, Zhihua
    Chen, Guang-Hong
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (20): : 6709 - 6721
  • [47] Assessment of the measurement procedure for dimensional metrology with X-ray computed tomography
    Kraemer, Alexandra
    Lanza, Gisela
    14TH CIRP CAT 2016 - CIRP CONFERENCE ON COMPUTER AIDED TOLERANCING, 2016, 43 : 362 - 367
  • [48] VALIDATION OF THE MEASUREMENT OF HEPATIC VOLUME BY 3-DIMENSIONAL COMPUTED-TOMOGRAPHY
    EVRARD, S
    MOYSES, B
    GHNASSIA, JP
    VIX, M
    MUTTER, D
    METHELIN, G
    MARESCAUX, J
    ANNALES DE CHIRURGIE, 1992, 46 (07): : 601 - 604
  • [49] Measurement of Carpal Alignment Indices Using 3-Dimensional Computed Tomography
    Lee, Ki Won
    Bae, Joo Yul
    Seo, Dong-Kyo
    Kim, Sang Bum
    Lee, Hyun Il
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2018, 43 (08): : 771.e1 - 771.e7
  • [50] Measurement of the volume of oral tumors by three-dimensional spiral computed tomography
    Cavalcanti, MGP
    Vannier, MW
    DENTOMAXILLOFACIAL RADIOLOGY, 2000, 29 (01) : 35 - 40