Measurements of pelvic flexion angle using three-dimensional computed tomography

被引:185
|
作者
Nishihara, S
Sugano, N
Nishii, T
Ohzono, K
Yoshikawa, H
机构
[1] Osaka Univ, Sch Med, Dept Orthopaed Surg, Osaka 5650871, Japan
[2] Osaka Natl Hosp, Dept Orthopaed Surg, Osaka, Japan
关键词
D O I
10.1097/01.blo.0000069891.31220.fd
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of the current study was to evaluate whether safe acetabular component position depends on differences in pelvic location between the supine, standing, and sitting positions. The subjects of the current study were 101 patients who had total hip arthroplasty. Anteroposterior radiographs of the pelvis with the patients in the supine, standing, and sitting positions were obtained preoperatively and 1 year after total hip arthroplasty. Computed tomography images of the pelvis were obtained preoperatively. Using image matching between the three-dimensional computed tomography model and anteroposterior radiograph, pelvic flexion angles with the patient in the supine, standing, and sitting positions were calculated. The mean preoperative pelvic flexion angle was 5degrees +/- 9degrees (range, -37degrees-30degrees) in the supine position, 3degrees +/- 12degrees (range, -46degrees-33degrees) in the standing position, and -29degrees +/- 12degrees (range, -62degrees-10degrees) in the sitting position. Because there was much intersubject variability in pelvic flexion angle, it is not appropriate to determine orientation of the acetabular component from anatomic landmarks. In 90% of the cases, the difference in pelvic flexion angle between the supine and standing positions preoperatively was 10degrees or less. In 90% of the cases, there was 20degrees or greater extension of the pelvis from the supine position to the sitting position preoperatively, and the safe range of flexion of the hip from anterior prosthetic impingement in the sitting position was 20degrees or greater than that in the supine position. Preoperative pelvic position in each case was almost completely maintained 1 year after total hip arthroplasty. It is reasonable to regard the pelvic position in the supine position as the functional pelvic position and proper pelvic reference frame in determining optimal orientation of the acetabular component in 90% of cases before and 1 year after total hip arthroplasty, although an adjustment of orientation of the acetabular component was needed for the remaining cases.
引用
收藏
页码:140 / 151
页数:12
相关论文
共 50 条
  • [1] Three-dimensional gas temperature measurements by computed tomography with incident angle variable interferometer
    Tomioka, Satoshi
    Nishiyama, Shusuke
    Heshmat, Samia
    Hashimoto, Yasuhiro
    Kurita, Kodai
    COMPUTATIONAL IMAGING XIII, 2015, 9401
  • [2] The accuracy of measurements of three-dimensional computed tomography reconstructions
    Covino, SW
    Mitnick, RJ
    Shprintzen, RJ
    Cisneros, GJ
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1996, 54 (08) : 982 - 990
  • [3] Pelvic incidence measurement using a computed tomography data-based three-dimensional pelvic model
    Chen, Hong-Fang
    Mi, Jie
    Zhang, Heng-Hui
    Zhao, Chang-Qing
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2019, 14 (1)
  • [4] Pelvic incidence measurement using a computed tomography data-based three-dimensional pelvic model
    Hong-Fang Chen
    Jie Mi
    Heng-Hui Zhang
    Chang-Qing Zhao
    Journal of Orthopaedic Surgery and Research, 14
  • [5] Sex estimation using subpubic angle from reconstructed three-dimensional computed tomography pelvic model in a contemporary Malaysian population
    Ali, Siti Hanum Mohd
    Omari, Normaliza
    Shafie, Mohamed Swarhib
    Ismail, Nik Azuan Nik
    Had, Helmi
    Nor, Faridah Mohd
    ANATOMY & CELL BIOLOGY, 2020, 53 (01) : 27 - 35
  • [7] Accuracy of craniofacial measurements:: computed tomography and three-dimensional computed tomography compared with stereolithographic models
    Fruehwald, Julia
    Schicho, Kurt A.
    Figl, Michael
    Benesch, Thomas
    Watzinger, Franz
    Kainberger, Franz
    JOURNAL OF CRANIOFACIAL SURGERY, 2008, 19 (01) : 22 - 26
  • [8] Cephalometric Angular Measurements of the Mandible Using Three-Dimensional Computed Tomography Scans in Koreans
    Kim, Yong Hyun
    Kang, Seok Joo
    Sun, Hook
    ARCHIVES OF PLASTIC SURGERY-APS, 2016, 43 (01): : 32 - 37
  • [9] Measurement of Flexion Angle of the Finger Joint during Cylinder Gripping Using a Three-Dimensional Bone Model Built by X-Ray Computed Tomography
    Shimawaki, Satoshi
    Murai, Takuma
    Nakabayashi, Masataka
    Sugimoto, Hideharu
    APPLIED BIONICS AND BIOMECHANICS, 2019, 2019
  • [10] Three-dimensional pelvimetry by computed tomography
    Lenhard, M.
    Johnson, T.
    Weckbach, S.
    Nikolaou, K.
    Friese, K.
    Hasbargen, U.
    RADIOLOGIA MEDICA, 2009, 114 (05): : 827 - 834