Studies on measurement uncertainty and economy of dimensional computed tomography measurements on selected examples

被引:1
|
作者
Hiller, Jochen [1 ]
Sawczyn, Nikolas [2 ]
Imkamp, Dietrich [3 ]
Uhlmann, Eckart [2 ,4 ]
机构
[1] Tech Hsch Deggendorf, Fraunhofer Anwendungs Zentrum Comp Tomog Messtech, Fak Maschinenbau & Mechatron, Edlmairstr 9, D-94469 Deggendorf, Germany
[2] Tech Univ Berlin, Inst Werkzeugmaschinen & Fabrikbetrieb IWF, Pascalstr 8-9, D-10587 Berlin, Germany
[3] Carl Zeiss Ind Messtech GmbH, Carl Zeiss Str 22, D-73447 Oberkochen, Germany
[4] Fraunhofer Inst Prod Sanlagen & Konstrukt Tech IP, Pascalstr 8-9, D-10587 Berlin, Germany
关键词
Production measurement technology; conformity testing; computed tomography; measurement uncertainty; METROLOGY;
D O I
10.1515/teme-2016-0050
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Industrial computed tomography (CT) is increasingly being applied for non-destructive testing of components in process quality assurance. The advantage over tactile or optical measuring methods is in particular the possibility to measure both, outer as well as inner geometry features non-destructively. In this article, possibilities for increasing the economy of CT measurements by simultaneous tomographic scanning of several components in the CT measuring volume are being investigated by using selected components, and the measurement uncertainty for the individual scanning settings is determined experimentally.
引用
收藏
页码:336 / 347
页数:12
相关论文
共 50 条
  • [31] Three dimensional bulk index inhomogeneity measurement using computed tomography
    Stamper, BL
    Burge, JH
    Dallas, WJ
    OPTICAL MANUFACUTRING AND TESTING V, 2003, 5180 : 413 - 420
  • [32] Validation of Optical Three-Dimensional Plagiocephalometry by Computed Tomography, Direct Measurement, and Indirect Measurements Using Thermoplastic Bands
    Spitzer, Martin Joachim
    Kramer, Manuel
    Neukam, Friedrich Wilhelm
    Nkenke, Emeka
    JOURNAL OF CRANIOFACIAL SURGERY, 2011, 22 (01) : 129 - 134
  • [33] Surface extraction algorithm influence on the uncertainty assessment and tolerance compliance of computed tomography measurements
    Yague-Fabra, Jose A.
    Jimenez, R.
    Ontiveros, S.
    Torralba, M.
    Tosello, G.
    15TH CIRP CONFERENCE ON COMPUTER AIDED TOLERANCING, CIRP CAT 2018, 2018, 75 : 119 - 124
  • [34] Reliability of measurements performed on two dimensional and three dimensional computed tomography in glenoid assessment for instability
    Kubicka, Anna Maria
    Stefaniak, Jakub
    Lubiatowski, Przemysaw
    Dugosz, Jan
    Dzianach, Marcin
    Redman, Marcin
    Piontek, Janusz
    Romanowski, Leszek
    INTERNATIONAL ORTHOPAEDICS, 2016, 40 (12) : 2581 - 2588
  • [35] Reliability of measurements performed on two dimensional and three dimensional computed tomography in glenoid assessment for instability
    Anna Maria Kubicka
    Jakub Stefaniak
    Przemysław Lubiatowski
    Jan Długosz
    Marcin Dzianach
    Marcin Redman
    Janusz Piontek
    Leszek Romanowski
    International Orthopaedics, 2016, 40 : 2581 - 2588
  • [36] Uncertainty measurement of radiomics features against inherent quantum noise in computed tomography imaging
    Shu-Ju Tu
    Wei-Yuan Chen
    Chen-Te Wu
    European Radiology, 2021, 31 : 7865 - 7875
  • [37] Uncertainty measurement of radiomics features against inherent quantum noise in computed tomography imaging
    Tu, Shu-Ju
    Chen, Wei-Yuan
    Wu, Chen-Te
    EUROPEAN RADIOLOGY, 2021, 31 (10) : 7865 - 7875
  • [38] Uncertainty in measurement for x-ray-computed tomography using calibrated work pieces
    Schmitt, Robert
    Niggemann, Christian
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2010, 21 (05)
  • [39] EFFECTS OF PHANTOM DESIGN AND MEASUREMENT TECHNIQUE ON COMPUTED-TOMOGRAPHY DOSE MEASUREMENTS
    PENTLOW, KS
    ROTHENBERG, LN
    FLEISCHMAN, R
    MEDICAL PHYSICS, 1983, 10 (05) : 734 - 734
  • [40] A technique for the measurement of visceral fat by ultrasonography: Comparison of measurements by ultrasonography and computed tomography
    Hirooka, M
    Kumagi, T
    Kurose, K
    Nakanishi, S
    Michitaka, K
    Matsuura, B
    Horiike, N
    Onji, M
    INTERNAL MEDICINE, 2005, 44 (08) : 794 - 799