Cross-calibration of a GE iDXA and Prodigy for Total and Regional Body Bone Parameters: The Importance of Using Cross-calibration Equations for Longitudinal Monitoring After a System Upgrade

被引:9
|
作者
Rhodes, Laura A. [1 ]
Cooper, William [1 ]
Oldroyd, Brian [1 ]
Hind, Karen [2 ]
机构
[1] Univ Leeds, Div Med Phys, Leeds LS2 9NL, W Yorkshire, England
[2] Leeds Metropolitan Univ, Carnegie Res Inst, Leeds LS1 3HE, W Yorkshire, England
关键词
Cross-calibration; iDXA; prodigy; regional total body; X-RAY ABSORPTIOMETRY; MINERAL DENSITY; PRECISION;
D O I
10.1016/j.jocd.2013.09.009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We aimed to determine if cross-calibration equations could be applied to convert GE Lunar Prodigy total and regional bone measurements to the GE iDXA model to support longitudinal monitoring of subjects. The cross-calibration group comprised 63 adults (age 45.1 [12.8] yr; body mass index: 25.6 [3.7] kg/m(2)) and the validation group comprised 25 adults (age 40.5 [11.5] yr; body mass index: 25.7 [3.5] kg/m(2)). The parameters reported were total and regional bone mineral density (BMD), bone mineral content, and bone area. There were significant differences between densitometers for all anatomical regions and reported bone parameters (p < 0.0001); iDXA reported lower BMD than the Prodigy apart from the ribs. Linear regression indicated good agreement for all measurements. Bland-Altman analyses indicated significant bias for all measurements and that cross-calibration equations were required. The derived cross-calibration equations were effective in reducing differences between predicted and measured results for each parameter and at each region apart from leg BMD, where the difference remained significant (0.013 g/cm(2); p < 0.05). Our results indicate that cross-calibration is important to maintain comparability of total body-derived regional bone measurements between the Lunar Prodigy and iDXA.
引用
收藏
页码:496 / 504
页数:9
相关论文
共 42 条
  • [31] Cross Calibration of Hologic QDR2000 and GE Lunar Prodigy for Whole Body Bone Mineral Density and Body Composition Measurements
    Pearson, Derek
    Horton, Barbara
    Green, Desmond J.
    JOURNAL OF CLINICAL DENSITOMETRY, 2011, 14 (03) : 294 - 301
  • [32] In-vivo bone mineral measurement of the hip using the lexxos cone beam densitometer: Precision and cross-calibration with hologic densitometers.
    Knapp, KM
    Koa-Sales, RM
    Boudousq, V
    Ruiz, I
    Kotzki, O
    Chappard, D
    Audran, M
    JOURNAL OF BONE AND MINERAL RESEARCH, 2003, 18 : S315 - S315
  • [33] Bone mineral and body composition measurements: Cross-calibration of pencil-beam and fan-beam dual-energy X-ray absorptiometers
    Ellis, KJ
    Shypailo, RJ
    JOURNAL OF BONE AND MINERAL RESEARCH, 1998, 13 (10) : 1613 - 1618
  • [34] CROSS-CALIBRATION OF BMD MEASUREMENT BETWEEN A DEDICATED PQCT SCANNER AND QCT OF PERIPHERAL SITES USING A CLINICAL WHOLE-BODY HELICAL CT SCANNER
    Bodeen, G.
    Mahboubi, S.
    Brown, J. K.
    Zemel, B. S.
    Brett, A.
    Leonard, M. B.
    OSTEOPOROSIS INTERNATIONAL, 2014, 25 : S347 - S347
  • [35] CROSS-CALIBRATION OF BMD MEASUREMENT BETWEEN A DEDICATED PQCT SCANNER AND QCT OF PERIPHERAL SITES USING A CLINICAL WHOLE-BODY HELICAL CT SCANNER
    Bodeen, Gabriel
    Mahboubi, Soroosh
    Brown, J. Keenan
    Zemel, Babette S.
    Brett, Alan
    Leonard, Mary B.
    OSTEOPOROSIS INTERNATIONAL, 2014, 25 : S507 - S508
  • [36] Cross-Calibration Study of The Stratos And Hologic QDR 4500A Dual-Energy X-Ray Absorptiometers to Assess Bone Mineral Density And Body Composition
    Maimoun, Laurent
    Alonso, Sandrine
    Mahadea, Krishna Kunal
    Boudousq, Vincent
    Mura, Thibault
    Mariano-Goulart, Denis
    JOURNAL OF CLINICAL DENSITOMETRY, 2023, 26 (04)
  • [37] Cross-calibration of lunar DPX-IQ and DPX dual-energy X-ray densitometers for bone mineral measurements in women -: Effect of body anthropometry
    Saarelainen, J
    Honkanen, R
    Vanninen, E
    Kröger, H
    Tuppurainen, M
    Niskanen, L
    Jurvelin, JS
    JOURNAL OF CLINICAL DENSITOMETRY, 2005, 8 (03) : 320 - 329
  • [38] Cross-calibration of areal bone mineral densities and body composition between DMS Stratos and Hologic Horizon A dual- energy X-ray absorptiometers: The effect of body mass index
    Maimoun, Laurent
    Alonso, Sandrine
    Mahadea, Krishna Kunal
    Dubois, Julien
    Paunet, Tom
    Kucharczak, Florentin
    Nande, Lisa Maimoun
    Boudousq, Vincent
    Mura, Thibault
    Mariano-Goulart, Denis
    JOURNAL OF CLINICAL DENSITOMETRY, 2025, 28 (01)
  • [39] MONITORING OF THE CROSS-CALIBRATION BIASES BETWEEN THE S-NPP AND NOAA-20 VIIRS SENSOR DATA RECORDS USING GOES ADVANCED BASELINE IMAGER AS A TRANSFER
    Huang, Jingfeng
    Yan, Banghua
    Sun, Ninghai
    IGARSS 2020 - 2020 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, 2020, : 6393 - 6396
  • [40] Executive Summary of the 2019 ISCD Position Development Conference on Monitoring Treatment, DXA Cross-calibration and Least Significant Change, Spinal Cord Injury, Peri-prosthetic and Orthopedic Bone Health, Transgender Medicine, and Pediatrics
    Shuhart, Christopher R.
    Yeap, Swan Sim
    Anderson, Paul A.
    Jankowski, Lawrence G.
    Lewiecki, E. Michael
    Morse, Leslie R.
    Rosen, Harold N.
    Weber, David R.
    Zemel, Babette S.
    Shepherd, John A.