Cross-calibration of areal bone mineral densities and body composition between DMS Stratos and Hologic Horizon A dual- energy X-ray absorptiometers: The effect of body mass index

被引:0
|
作者
Maimoun, Laurent [1 ,2 ]
Alonso, Sandrine [3 ]
Mahadea, Krishna Kunal [4 ]
Dubois, Julien [5 ,6 ]
Paunet, Tom [1 ]
Kucharczak, Florentin [1 ,3 ]
Nande, Lisa Maimoun [4 ]
Boudousq, Vincent [4 ,7 ]
Mura, Thibault [3 ,4 ]
Mariano-Goulart, Denis [1 ,2 ]
机构
[1] CHU Montpellier, Hop Lapeyronie, Serv Med Nucl, Montpellier, France
[2] Univ Montpellier UM, Physiol & Med Expt Coeur & Muscles PhyMedEx, INSERM, CNRS, Montpellier, France
[3] CHU Nimes, Serv BESPIM Biostat Epidemiol Clin Sante Publ & In, Nimes, France
[4] Univ Montpellier, Montpellier, France
[5] Montpellier Univ, Montpellier Univ Hosp, Dept Radiopharm, Montpellier, France
[6] Univ Montpellier, Canc Res Inst Montpellier IRCM, INSERM U1194, Montpellier, France
[7] CHU Nimes, Hop Caremeau, Serv Med Nucl, Nimes, France
关键词
Cross-calibration; Dual X-ray absorptiometry (DXA); Stratos; Horizon A; Areal bone mineral density (aBMD); Body composition; Body mass index; PENCIL-BEAM; TISSUE MEASUREMENTS; PRODIGY; IDXA; PRECISION; DENSITOMETERS; PARAMETERS; SPINE; FAT; HIP;
D O I
10.1016/j.jocd.2024.101553
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: The aim of this study was to investigate the correlations between areal bone mineral density (aBMD) and body composition measured by two dual-energy X-ray absorptiometers (DXA), the DMS Stratos (R) (STR) and the Hologic Horizon A (R) (HRZ), and then generate cross-calibration equations between the two scanners. Methods: Repeat scans were obtained from 251 adults (85 % female), 36 +/- 14 years old with mean body mass index (BMI) of 28.7 +/- 11.1 kg/m2, using HRZ (fan-beam technology) and STR (pencil-beam technology). aBMD was measured at whole body [WB], femoral neck [FN], total hip [TH], lumbar spine [LS] and radius, while fat mass [FM] and lean tissue mass [LTM] were determined at whole body and at android and gynoid subregions. Results: Compared to HRZ, STR underestimated both aBMD at WB and radius and LTM at WB and android and gynoid regions. Conversely, STR overestimated aBMD at FN, TH, LS and FM at WB android and gynoid regions. Except for WB bone mineral content (r = 0.87) and WB aBMD (r = 0.84), there were strong correlations of aBMD and body composition between the two DXAs (r > 0.91; p < 0.0001). Several of the parameters that required the determination of specific cross-calibration equations because of the significant bias between the two DXAs were found to be influenced by BMI. Conclusions: Although the data from the STR and the HRZ were highly correlated for aBMD and body composition parameters, a systematic measurement bias between two DXAs was observed. The development of cross-calibration equations fully corrected these differences and they may thus be useful for multicenter studies when scans are performed with STR and HRZ.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Cross-Calibration Study of The Stratos And Hologic QDR 4500A Dual-Energy X-Ray Absorptiometers to Assess Bone Mineral Density And Body Composition
    Maimoun, Laurent
    Alonso, Sandrine
    Mahadea, Krishna Kunal
    Boudousq, Vincent
    Mura, Thibault
    Mariano-Goulart, Denis
    JOURNAL OF CLINICAL DENSITOMETRY, 2023, 26 (04)
  • [2] Bone mineral and body composition measurements: Cross-calibration of pencil-beam and fan-beam dual-energy X-ray absorptiometers
    Ellis, KJ
    Shypailo, RJ
    JOURNAL OF BONE AND MINERAL RESEARCH, 1998, 13 (10) : 1613 - 1618
  • [3] Precision of the Hologic Horizon A dual energy X-ray absorptiometry in the assessment of body composition
    Cheung, Y. M.
    Roff, G.
    Grossmann, M.
    OBESITY RESEARCH & CLINICAL PRACTICE, 2020, 14 (06) : 514 - 518
  • [4] PRECISION AND ACCURACY OF MEASUREMENTS OF WHOLE-BODY BONE-MINERAL - COMPARISONS BETWEEN HOLOGIC, LUNAR AND NORLAND DUAL-ENERGY X-RAY A ABSORPTIOMETERS
    TOTHILL, P
    AVENELL, A
    REID, DM
    BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (804): : 1210 - 1217
  • [5] Cross-calibration of two dual-energy X-ray absorptiometry devices for the measurement of body composition in young children
    Lyons-Reid, Jaz
    Kenealy, Timothy
    Albert, Benjamin B.
    Ward, Kate A.
    Harvey, Nicholas
    Godfrey, Keith M.
    Chan, Shiao-Yng
    Cutfield, Wayne S.
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [6] Cross-calibration of lunar DPX-IQ and DPX dual-energy X-ray densitometers for bone mineral measurements in women -: Effect of body anthropometry
    Saarelainen, J
    Honkanen, R
    Vanninen, E
    Kröger, H
    Tuppurainen, M
    Niskanen, L
    Jurvelin, JS
    JOURNAL OF CLINICAL DENSITOMETRY, 2005, 8 (03) : 320 - 329
  • [7] Cross-calibration of body-composition techniques against dual-energy X-ray absorptiometry in young children
    Goran, MI
    Driscoll, P
    Johnson, R
    Nagy, TR
    Hunter, G
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1996, 63 (03): : 299 - 305
  • [8] Cross-calibration Of Two Dual-energy X-ray Absorptiometry Systems For Body Composition Measurements In Young Adults
    Mejia, Ana
    Huatran, Johnny
    Ramirez, Erick
    Escalante, Guillermo
    Haddock, Bryan
    Chen, Zhaojing
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2020, 52 (07) : 871 - 872
  • [9] Cross-calibration of two dual-energy X-ray absorptiometry devices for the measurement of body composition in young children
    Jaz Lyons-Reid
    Timothy Kenealy
    Benjamin B. Albert
    Kate A. Ward
    Nicholas Harvey
    Keith M. Godfrey
    Shiao-Yng Chan
    Wayne S. Cutfield
    Scientific Reports, 12
  • [10] ASSESSMENT OF THE IMPACT OF THE LEAN MASS WITH BODY COMPOSITION BY DUAL-ENERGY X-RAY ABSORPTIOMETRY ON THE BONE MINERAL DENSITY
    Nikolov, M.
    Nikolov, N.