Prolongation and optimization of Doppler enhancement with a microbubble US contrast agent by using continuous infusion:: Preliminary experience

被引:115
|
作者
Albrecht, T
Urbank, A
Mahler, M
Bauer, A
Doré, CJ
Blomley, MJK
Cosgrove, DO
Schlief, R
机构
[1] Univ London Imperial Coll Sci Technol & Med, Sch Med, Hammersmith Hosp, Dept Imaging, London, England
[2] Univ London Imperial Coll Sci Technol & Med, Sch Med, Hammersmith Hosp, Dept Med Stat & Evaluat, London, England
[3] Schering AG, Dept Clin Dev Diagnost, D-1000 Berlin, Germany
关键词
arteries; femoral; US; carotid arteries; microbubbles; ultrasound; (US); contrast media; Doppler studies;
D O I
10.1148/radiology.207.2.9577478
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To investigate whether continuous infusion of echo-enhancing contrast agent for up to 15 minutes can provide uniform and prolonged enhancement. MATERIALS AND METHODS: Six volunteers each received one bolus and three infusions of a microbubble contrast agent over 6-15 minutes at (a) a standard rate (mean, 2.08 mL/min), (b) a fast rate at twice the standard rate, and (c) a slow rate at half the standard rate. Spectral Doppler intensitometry of the femoral artery was performed for all infusions. Spectral Doppler ultrasound (US) scans of the femoral artery and color Doppler US scans of the carotid artery were subjectively assessed. RESULTS: All infusions provided-an equilibrium plateau of constant prolonged enhancement starting after 2 minutes and lasting until the end of the infusion. Enhancement at the plateau was +13 dB (slow rate), +17.1 dB (standard rate), and +18.3 dB (fast rate) compared with baseline. Saturation artifacts with infusions were markedly fewer than those with bolus injections. Dose effectiveness (duration of enhancement that measured at least 7.5 dB per gram of contrast agent) was markedly improved with the infusions, from 0.8 min/g for the bolus to 2.6 min/g for the slow infusion. CONCLUSION: Continuous infusion of the microbubble contrast agent provided prolonged and uniform enhancement of Doppler signals and improved image quality by minimizing saturation artifacts.
引用
收藏
页码:339 / 347
页数:9
相关论文
共 38 条
  • [31] Diagnostic challenges in patients with tumors - Case 3. Normal-sized ovarian cancer detected by color doppler ultrasound using a microbubble contrast agent
    Emoto, M
    Fujimitsu, R
    Iwasaki, H
    Kawarabayashi, T
    JOURNAL OF CLINICAL ONCOLOGY, 2003, 21 (19) : 3703 - 3705
  • [32] Transjugular intrahepatic portosystemic shunts: Pictorial review and preliminary experience using echo enhanced contrast agent pesda.
    Surjan, Rodrigo C.
    Oliveira, Andre C.
    Sepulveda, Ailton, Jr.
    Marcelino, Antonio S.
    Chammas, Maria C.
    Cerri, Giovanni G.
    Bacchella, Telesforo
    Machado, Marcel C.
    LIVER TRANSPLANTATION, 2007, 13 (06) : S210 - S210
  • [33] Contrast-enhanced power Doppler sonography of malignant ovarian tumors using harmonic flash-echo imaging: Preliminary experience
    Kohzuki, M
    Kanzaki, T
    Murata, Y
    JOURNAL OF CLINICAL ULTRASOUND, 2005, 33 (05) : 237 - 242
  • [34] Improved imaging of liver metastases with stimulated acoustic emission in the late phase of enhancement with the US contrast agent SH U 508A: Early experience
    Blomley, MJK
    Albrecht, T
    Cosgrove, DO
    Patel, N
    Jayaram, V
    Butler-Barnes, J
    Eckersley, RJ
    Bauer, A
    Schlief, R
    RADIOLOGY, 1999, 210 (02) : 409 - 416
  • [35] Comparison of right and left ventricular enhancement times using a microbubble contrast agent between proximal humeral intraosseous access and brachial intravenous access during cardiopulmonary resuscitation in adults
    Cho, Yongchul
    You, Yeonho
    Park, Jung Soo
    Min, Jin Hong
    Yoo, Insool
    Jeong, Wonjoon
    Ryu, Seung
    Lee, Jinwoong
    Kim, Seungwhan
    Cho, Sung Uk
    Oh, Se Kwang
    Lee, Junwan
    Ahn, Hong Joon
    RESUSCITATION, 2018, 129 : 90 - 93
  • [36] ALBUNEX ULTRASOUND CONTRAST AGENT PRODUCES A PHYSIOLOGICAL ENHANCEMENT OF RIGHT AND LEFT HEART DOPPLER SIGNALS WITHOUT CHANGING BLOOD-FLOW VELOCITIES - EXPERIMENTAL STUDIES IN DOGS AND INVITRO COLOR FLOW AND CONTINUOUS WAVE DOPPLER STUDIES
    MURILLO, A
    MOISES, V
    VALDESCRUZ, L
    CIRCULATION, 1992, 86 (04) : 504 - 504
  • [37] Monitoring Neoadjuvant Chemotherapy for Breast Cancer by Using Three-dimensional Subharmonic Aided Pressure Estimation and Imaging with US Contrast Agents: Preliminary Experience
    Nam, Kibo
    Eisenbrey, John R.
    Stanczak, Maria
    Sridharan, Anush
    Berger, Adam C.
    Avery, Tiffany
    Palazzo, Juan P.
    Forsberg, Flemming
    RADIOLOGY, 2017, 285 (01) : 53 - 62
  • [38] Dynamic Contrast-Enhanced MRI of the Prostate With High Spatiotemporal Resolution Using Compressed Sensing, Parallel Imaging, and Continuous Golden-Angle Radial Sampling: Preliminary Experience
    Rosenkrantz, Andrew B.
    Geppert, Christian
    Grimm, Robert
    Block, Tobias K.
    Glielmi, Christian
    Feng, Li
    Otazo, Ricardo
    Ream, Justin M.
    Romolo, Melanie Moccaldi
    Taneja, Samir S.
    Sodickson, Daniel K.
    Chandarana, Hersh
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 41 (05) : 1365 - 1373