Prolongation and optimization of Doppler enhancement with a microbubble US contrast agent by using continuous infusion:: Preliminary experience

被引:115
|
作者
Albrecht, T
Urbank, A
Mahler, M
Bauer, A
Doré, CJ
Blomley, MJK
Cosgrove, DO
Schlief, R
机构
[1] Univ London Imperial Coll Sci Technol & Med, Sch Med, Hammersmith Hosp, Dept Imaging, London, England
[2] Univ London Imperial Coll Sci Technol & Med, Sch Med, Hammersmith Hosp, Dept Med Stat & Evaluat, London, England
[3] Schering AG, Dept Clin Dev Diagnost, D-1000 Berlin, Germany
关键词
arteries; femoral; US; carotid arteries; microbubbles; ultrasound; (US); contrast media; Doppler studies;
D O I
10.1148/radiology.207.2.9577478
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To investigate whether continuous infusion of echo-enhancing contrast agent for up to 15 minutes can provide uniform and prolonged enhancement. MATERIALS AND METHODS: Six volunteers each received one bolus and three infusions of a microbubble contrast agent over 6-15 minutes at (a) a standard rate (mean, 2.08 mL/min), (b) a fast rate at twice the standard rate, and (c) a slow rate at half the standard rate. Spectral Doppler intensitometry of the femoral artery was performed for all infusions. Spectral Doppler ultrasound (US) scans of the femoral artery and color Doppler US scans of the carotid artery were subjectively assessed. RESULTS: All infusions provided-an equilibrium plateau of constant prolonged enhancement starting after 2 minutes and lasting until the end of the infusion. Enhancement at the plateau was +13 dB (slow rate), +17.1 dB (standard rate), and +18.3 dB (fast rate) compared with baseline. Saturation artifacts with infusions were markedly fewer than those with bolus injections. Dose effectiveness (duration of enhancement that measured at least 7.5 dB per gram of contrast agent) was markedly improved with the infusions, from 0.8 min/g for the bolus to 2.6 min/g for the slow infusion. CONCLUSION: Continuous infusion of the microbubble contrast agent provided prolonged and uniform enhancement of Doppler signals and improved image quality by minimizing saturation artifacts.
引用
收藏
页码:339 / 347
页数:9
相关论文
共 38 条
  • [21] DEFINITION OF CONTRAST ENHANCEMENT PHASES OF THE LIVER USING A PERFLUORO-BASED MICROBUBBLE AGENT, PERFLUBUTANE MICROBUBBLES
    Shunichi, Sasaki
    Hiroko, Iijima
    Fuminori, Moriyasu
    Waki, Hidehiko
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2009, 35 (11): : 1819 - 1827
  • [22] Pulse-inversion harmonic US with microbubble contrast agent: Contrast-enhancement pattern analysis for characterization of hepatocellular carcinoma, metastasis and hamangioma
    Yoon, K
    Kim, EA
    Park, SH
    Park, K
    Jhung, S
    Won, J
    RADIOLOGY, 2001, 221 : 324 - 324
  • [23] HEPATIC-TUMORS - SIGNAL ENHANCEMENT AT DOPPLER US AFTER INTRAVENOUS-INJECTION OF A CONTRAST AGENT
    GOLDBERG, BB
    HILPERT, PL
    BURNS, PN
    LIU, JB
    NEWMAN, LM
    MERTON, DA
    WITLIN, LA
    RADIOLOGY, 1990, 177 (03) : 713 - 717
  • [24] Harmonic hepatic US with microbubble contrast agent: Initial experience showing improved characterization of hemangioma, hepatocellular carcinoma,and metastasis
    Wilson, SR
    Burns, PN
    Muradali, D
    Wilson, JA
    Lai, XM
    RADIOLOGY, 2000, 215 (01) : 153 - 161
  • [25] EFFECT OF ULTRASOUND TRANSMIT POWER ON LIVER ENHANCEMENT FOLLOWING THE ADMINISTRATION OF IMAGENT US, A PERFLUOROCHEMICAL-STABILIZED MICROBUBBLE CONTRAST AGENT
    MATTREY, RF
    STEINBACH, GC
    BAKER, KG
    BRODERDORF, SK
    HALL, LA
    RADIOLOGY, 1995, 197 : 403 - 403
  • [27] Assessment of cerebral autoregulation with transcranial Doppler sonography in poor bone windows using constant infusion of an ultrasound contrast agent
    Lorenz, Matthias W.
    Thoelen, Nina
    Loesel, Nadine
    Lienerth, Christian
    Gonzalez, Marilen
    Humpich, Marek
    Roelz, Waltraud
    Dvorak, Florian
    Sitzer, Matthias
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (03): : 345 - 353
  • [28] Focal hepatic lesions: Contrast-enhancement patterns at pulse-inversion harmonic US using a microblubble contrast agent
    Kim, EA
    Yoon, KH
    Lee, YH
    Kim, HW
    Juhng, SK
    Won, JJ
    KOREAN JOURNAL OF RADIOLOGY, 2003, 4 (04) : 224 - 233
  • [29] Diagnostic utility of an echo-contrast agent in patients with synovitis using power Doppler ultrasound: a preliminary study with comparison to contrast-enhanced MRI
    Magarelli, N
    Guglielmi, G
    Di Matteo, L
    Tartaro, A
    Mattei, PA
    Bonomo, L
    EUROPEAN RADIOLOGY, 2001, 11 (06) : 1039 - 1046
  • [30] Diagnostic utility of an echo-contrast agent in patients with synovitis using power Doppler ultrasound: a preliminary study with comparison to contrast-enhanced MRI
    Nicola Magarelli
    Giuseppe Guglielmi
    Luigi Di Matteo
    Armando Tartaro
    Peter A. Mattei
    Lorenzo Bonomo
    European Radiology, 2001, 11 : 1039 - 1046