Prolongation and optimization of Doppler enhancement with a microbubble US contrast agent by using continuous infusion:: Preliminary experience

被引:115
|
作者
Albrecht, T
Urbank, A
Mahler, M
Bauer, A
Doré, CJ
Blomley, MJK
Cosgrove, DO
Schlief, R
机构
[1] Univ London Imperial Coll Sci Technol & Med, Sch Med, Hammersmith Hosp, Dept Imaging, London, England
[2] Univ London Imperial Coll Sci Technol & Med, Sch Med, Hammersmith Hosp, Dept Med Stat & Evaluat, London, England
[3] Schering AG, Dept Clin Dev Diagnost, D-1000 Berlin, Germany
关键词
arteries; femoral; US; carotid arteries; microbubbles; ultrasound; (US); contrast media; Doppler studies;
D O I
10.1148/radiology.207.2.9577478
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To investigate whether continuous infusion of echo-enhancing contrast agent for up to 15 minutes can provide uniform and prolonged enhancement. MATERIALS AND METHODS: Six volunteers each received one bolus and three infusions of a microbubble contrast agent over 6-15 minutes at (a) a standard rate (mean, 2.08 mL/min), (b) a fast rate at twice the standard rate, and (c) a slow rate at half the standard rate. Spectral Doppler intensitometry of the femoral artery was performed for all infusions. Spectral Doppler ultrasound (US) scans of the femoral artery and color Doppler US scans of the carotid artery were subjectively assessed. RESULTS: All infusions provided-an equilibrium plateau of constant prolonged enhancement starting after 2 minutes and lasting until the end of the infusion. Enhancement at the plateau was +13 dB (slow rate), +17.1 dB (standard rate), and +18.3 dB (fast rate) compared with baseline. Saturation artifacts with infusions were markedly fewer than those with bolus injections. Dose effectiveness (duration of enhancement that measured at least 7.5 dB per gram of contrast agent) was markedly improved with the infusions, from 0.8 min/g for the bolus to 2.6 min/g for the slow infusion. CONCLUSION: Continuous infusion of the microbubble contrast agent provided prolonged and uniform enhancement of Doppler signals and improved image quality by minimizing saturation artifacts.
引用
收藏
页码:339 / 347
页数:9
相关论文
共 38 条
  • [11] Bolus Compared with Continuous Infusion of Microbubble Contrast Agent Using Real-Time Contrast Harmonic Imaging Ultrasound in Breast Tumors
    Saracco, A.
    Aspelin, P.
    Leifland, K.
    Themudo, R.
    Wilczek, B.
    Axelsson, R.
    ACTA RADIOLOGICA, 2009, 50 (08) : 854 - 859
  • [12] Bolus versus Continuous Infusion of Microbubble Contrast Agent for Liver Ultrasound by Using an Automatic Power Injector in Humans: A Pilot Study
    Quaia, Emilio
    Gennari, Antonio Giulio
    Angileri, Roberta
    Cova, Maria Assunta
    JOURNAL OF CLINICAL ULTRASOUND, 2016, 44 (03) : 136 - 142
  • [13] B-mode enhancement at phase-inversion US with air-based microbubble contrast agent: Initial experience in humans
    Albrecht, T
    Hoffmann, CW
    Schettler, S
    Overberg, A
    Ilg, M
    von Behren, PL
    Bauer, A
    Wolf, KJ
    RADIOLOGY, 2000, 216 (01) : 273 - 278
  • [14] Effects of microbubble contrast agent on breast tumors: Computer-assisted quantitative assessment with color Doppler US
    Huber, S
    Helbich, TH
    Kettenbach, J
    Zuna, I
    Delorme, S
    Dock, WI
    RADIOLOGY, 1997, 205 : 1479 - 1479
  • [15] Detection of histopathological differentiation with hepatocellular carcinoma by enhancement patterns using microbubble contrast US
    Wakui, N
    Sumino, Y
    Sawa, M
    Kanayama, M
    Fujita, Y
    Shin, H
    Shinohara, M
    Shinohara, M
    Watanabe, M
    Ishii, K
    Miki, K
    GASTROENTEROLOGY, 2004, 126 (04) : A726 - A726
  • [16] Optimization of color and spectral Doppler scanning of the renal arteries using a US contrast agent and second harmonic imaging
    Calliada, F
    Bottinelli, O
    Campani, R
    Sala, G
    Corradi, B
    Draghi, F
    RADIOLOGY, 1997, 205 : 430 - 430
  • [17] Computer-assisted quantitative assessment of power Doppler US: effects of microbubble contrast agent in the differentiation of breast tumors
    Kettenbach, J
    Helbich, TH
    Huber, A
    Zuna, I
    Dock, W
    EUROPEAN JOURNAL OF RADIOLOGY, 2005, 53 (02) : 238 - 244
  • [18] Radio-frequency ablation of hepatic metastases: Postprocedural assessment with a US microbubble contrast agent - Early experience
    Solbiati, L
    Goldberg, SN
    Ierace, T
    Dellanoce, M
    Livraghi, T
    Gazelle, GS
    RADIOLOGY, 1999, 211 (03) : 643 - 649
  • [19] Hepatocellular carcinoma treated with percutaneous radio-frequency ablation: Usefulness of power Doppler US with a microbubble contrast agent in evaluating therapeutic response-preliminary results
    Choi, D
    Lim, HK
    Kim, SH
    Lee, WJ
    Jang, HJ
    Lee, JY
    Paik, SW
    Koh, KC
    Lee, JH
    RADIOLOGY, 2000, 217 (02) : 558 - 563
  • [20] Effect of ultrasound transmit power on liver enhancement with Imagent(R) US, a PFC-stabilized microbubble contrast agent
    Sirlin, CB
    Girard, MS
    Steinbach, GC
    Baker, KG
    Broderdorf, SK
    Hall, LA
    Mattrey, RF
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 1997, 8 (01) : 82 - 88