Experimental study on temperature and performance of an open-cathode PEMFC stack under thermal radiation environment

被引:27
|
作者
Zhang, Jikai [1 ,2 ]
Wang, Changjian [1 ,3 ]
Zhang, Aifeng [1 ,2 ]
机构
[1] Hefei Univ Technol, Sch Civil Engn, Hefei 230009, Anhui, Peoples R China
[2] Anhui Int Joint Res Ctr Hydrogen Safety, Hefei 230009, Peoples R China
[3] Minist Educ, Engn Res Ctr Safety Crit Ind Measurement & Contro, Hefei, Peoples R China
关键词
Open-cathode PEMFC; Thermal radiation; Performance degradation; Temperature distribution; Single -cell voltage uniformity; MEMBRANE FUEL-CELL; IN-SITU MEASUREMENT; RELATIVE-HUMIDITY; BREATHING PEMFC; FLOW CHANNEL; AIR; SYSTEM; OPTIMIZATION; DESIGN; ANODE;
D O I
10.1016/j.apenergy.2022.118646
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The open-cathode proton exchange membrane fuel cell stack is an air-cooled stack, and has the characteristics of small footprint and high power density because of its unique configuration, combining oxidizer and coolant via axial fan. Depending on the demands of the application, proton exchange membrane fuel cells inevitably operate in harsh environments, such as high pressure, low or high temperature, etc. In this study, the performance of a 10-cell open-cathode PEMFC stack under thermal radiation was evaluated. The variations in cathode air temperature and relative humidity, stack temperature, output power and single-cell voltage under three different radiant heat fluxes were obtained by changing the load current and cathode air flow rate. The experimental results show that, even if the thermal radiation is beneficial to improve the stack temperature, the stack performance is not improved in all tested cases. Conversely, the degradation of stack power and failure of the stack continuous operation can be observed, especially for higher radiant heat flux, higher load current and lower air velocity. For the highest radiant heat flux in current study, the temperature of the first single cell closest to the radiant heat source exceeds the maximum allowable operating temperature of 65 degrees C due to the insufficient capacity of air cooling and the heating effect of radiant heat source. The significant drop in the first single-cell voltage results in the rapid degradation of the overall performance of the stack, and finally the stack fails to run continuously.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Experimental study on temperature and performance of an open-cathode PEMFC stack under thermal radiation environment
    Zhang, Jikai
    Wang, Changjian
    Zhang, Aifeng
    APPLIED ENERGY, 2022, 311
  • [2] High performance PEMFC stack with open-cathode at ambient pressure and temperature conditions
    Santa Rosa, D. T.
    Pinto, D. G.
    Silva, V. S.
    Silva, R. A.
    Rangel, C. M.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2007, 32 (17) : 4350 - 4357
  • [3] Experimental and theoretical study on improving the operating characteristics of an open-cathode PEMFC stack by generating periodic disturbances at anode
    Zhao, Jing
    Jian, Qifei
    Huang, Zipeng
    ENERGY CONVERSION AND MANAGEMENT, 2019, 196 : 1433 - 1444
  • [4] The effect of wind environment on temperature and performance of an open-cathode proton exchange membrane fuel cell stack
    Wang, Changjian
    Ma, Hongsheng
    Duan, Shuqi
    Zhao, Weiping
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2024, 149 (17) : 9587 - 9600
  • [5] Comprehensive Anode Parameter Study for an Open-Cathode PEMFC
    Zhao, Chen
    Xing, Shuang
    Liu, Wei
    Wang, Haijiang
    ENERGY & FUELS, 2020, 34 (06) : 7582 - 7590
  • [6] Experimental study on improving the dynamic characteristics of open-cathode PEMFC stack with dead-end anode by condensation and circulation of hydrogen
    Huang, Zipeng
    Jian, Qifei
    Zhao, Jing
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2020, 45 (38) : 19858 - 19868
  • [7] Experimental investigation of the thermal response of open-cathode proton exchange membrane fuel cell stack
    Jian, Qifei
    Huang, Bi
    Luo, Lizhong
    Zhao, Jing
    Cao, Songyang
    Huang, Zipeng
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2018, 43 (29) : 13489 - 13500
  • [8] Experimental analysis of a degraded open-cathode PEM fuel cell stack
    Strahl, Stephan
    Gasamans, Noemi
    Llorca, Jordi
    Husar, Attila
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2014, 39 (10) : 5378 - 5387
  • [9] The study on the performance of air-cooled open-cathode PEMFC with dead-ended anode
    Xiao, Fei
    Chen, Tao
    Chen, Ziyu
    Lan, Yang
    Zhang, Shaojie
    Liu, Shihua
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2025, 22 (03) : 570 - 581
  • [10] Experimental investigation of self-regulating capability of open-cathode PEMFC under different fan working conditions
    Yu, Xingzi
    Zhang, Caizhi
    Li, Mengxiao
    Chen, Bin
    Fan, Min
    Sheng, Xinfa
    Ma, Fangping
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2023, 48 (68) : 26599 - 26608