Modeling Bias Error in 4D Flow MRI Velocity Measurements

被引:8
|
作者
Rothenberger, Sean M. [1 ]
Zhang, Jiacheng [2 ]
Brindise, Melissa C. [2 ]
Schnell, Susanne [3 ]
Markl, Michael [4 ]
Vlachos, Pavlos P. [1 ,2 ]
Rayz, Vitaliy L. [1 ,2 ]
机构
[1] Purdue Univ, Weldon Sch Biomed Engn, W Lafayette, IN 47907 USA
[2] Purdue Univ, Sch Mech Engn, W Lafayette, IN 47907 USA
[3] Univ Greifswald, Inst Phys, D-17489 Greifswald, Germany
[4] Northwestern Univ, Feinberg Sch Med, Dept Radiol, Chicago, IL 60611 USA
基金
美国国家卫生研究院;
关键词
Magnetic resonance imaging; Velocity measurement; Measurement uncertainty; Mathematical models; Spatial resolution; Numerical models; Fluid flow measurement; Hemodynamics; magnetic resonance velocimetry (MRV); partial volume effects; phase contrast magnetic resonance imaging (PC-MRI); systematic error; WALL SHEAR-STRESS; PHASE-CONTRAST MRI; IN-VIVO; INTRACRANIAL ANEURYSMS; BLOOD-FLOW; PATTERNS; IMAGES;
D O I
10.1109/TMI.2022.3149421
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We present a model to estimate the bias error of 4D flow magnetic resonance imaging (MRI) velocity measurements. The local instantaneous bias error is defined as the difference between the expectation of the voxel's measured velocity and actual velocity at the voxel center. The model accounts for bias error introduced by the intra-voxel velocity distribution and partial volume (PV) effects. We assess the intra-voxel velocity distribution using a 3D Taylor Series expansion. PV effects and numerical errors are considered using a Richardson extrapolation. The model is applied to synthetic Womersley flow and in vitro and in vivo 4D flow MRI measurements in a cerebral aneurysm. The bias error model is valid for measurements with at least 3.75 voxels across the vessel diameter and signal-to-noise ratio greater than 5. All test cases exceeded this diameter to voxel size ratio with diameters, isotropic voxel sizes, and velocity ranging from 3-15mm, 0.5-1mm, and 0-60cm/s, respectively. The model accurately estimates the bias error in voxels not affected by PV effects. In PV voxels, the bias error is an order of magnitude higher, and the accuracy of the bias error estimation in PV voxels ranges from 67.3% to 108% relative to the actual bias error. The bias error estimated for in vivo measurements increased two-fold at systole compared to diastole in partial volume and non-partial volume voxels, suggesting the bias error varies over the cardiac cycle. This bias error model quantifies 4D flow MRI measurement accuracy and can help plan 4D flow MRI scans.
引用
收藏
页码:1802 / 1812
页数:11
相关论文
共 50 条
  • [31] Optimization of 4D flow MRI velocity field in the aorta with divergence-free smoothing
    Gao, Qi
    Liu, Xingli
    Wang, Hongping
    Wu, Peng
    Jin, Mansu
    Wei, RunJie
    Wang, Wei
    Niu, Zhaozhuo
    Zhao, Shihua
    Li, Fei
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2021, 59 (11-12) : 2237 - 2252
  • [32] Comparison of 2D and 4D Flow MRI Measurements for Hemodynamic Evaluation of the Fontan Palliation
    Listo, Elisa
    Martini, Nicola
    Salvadori, Stefano
    Valenti, Elisa
    Stagnaro, Nicola
    Trocchio, Gianluca
    Marrone, Chiara
    Clemente, Alberto
    Raimondi, Francesca
    Festa, Pierluigi
    Ali, Lamia Ait
    CONGENITAL HEART DISEASE, 2023, 18 (06) : 627 - 638
  • [33] Use of Multi-Velocity Encoding 4D Flow MRI to Improve Quantification of Flow Patterns in the Aorta
    Callaghan, Fraser M.
    Kozor, Rebecca
    Sherrah, Andrew G.
    Vallely, Michael
    Celermajer, David
    Figtree, Gemma A.
    Grieve, Stuart M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 43 (02) : 352 - 363
  • [34] The value of 4D flow MRI in cardiac assessment
    Nicholls, Mark
    EUROPEAN HEART JOURNAL, 2022, 43 (10) : 930 - 932
  • [35] Why 4D Flow MRI? Real Advantages
    Takehara, Yasuo
    Sekine, Tetsuro
    Obata, Takayuki
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2022, 21 (02) : 253 - 256
  • [36] 4D Flow MRI Applications for Aortic Disease
    Burris, Nicholas S.
    Hope, Michael D.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2015, 23 (01) : 15 - +
  • [37] Abdominal applications of quantitative 4D flow MRI
    Oechtering, Thekla H.
    Roberts, Grant S.
    Panagiotopoulos, Nikolaos
    Wieben, Oliver
    Roldan-Alzate, Alejandro
    Reeder, Scott B.
    ABDOMINAL RADIOLOGY, 2022, 47 (09) : 3229 - 3250
  • [38] On the limitations of echo planar 4D flow MRI
    Dillinger, Hannes
    Walheim, Jonas
    Kozerke, Sebastian
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (04) : 1806 - 1816
  • [39] Abdominal applications of quantitative 4D flow MRI
    Thekla H. Oechtering
    Grant S. Roberts
    Nikolaos Panagiotopoulos
    Oliver Wieben
    Alejandro Roldán-Alzate
    Scott B. Reeder
    Abdominal Radiology, 2022, 47 : 3229 - 3250
  • [40] Emerging Applications of Abdominal 4D Flow MRI
    Roldan-Alzate, Alejandro
    Francois, Christopher J.
    Wieben, Oliver
    Reeder, Scott B.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 207 (01) : 58 - 66