Modeling Bias Error in 4D Flow MRI Velocity Measurements

被引:8
|
作者
Rothenberger, Sean M. [1 ]
Zhang, Jiacheng [2 ]
Brindise, Melissa C. [2 ]
Schnell, Susanne [3 ]
Markl, Michael [4 ]
Vlachos, Pavlos P. [1 ,2 ]
Rayz, Vitaliy L. [1 ,2 ]
机构
[1] Purdue Univ, Weldon Sch Biomed Engn, W Lafayette, IN 47907 USA
[2] Purdue Univ, Sch Mech Engn, W Lafayette, IN 47907 USA
[3] Univ Greifswald, Inst Phys, D-17489 Greifswald, Germany
[4] Northwestern Univ, Feinberg Sch Med, Dept Radiol, Chicago, IL 60611 USA
基金
美国国家卫生研究院;
关键词
Magnetic resonance imaging; Velocity measurement; Measurement uncertainty; Mathematical models; Spatial resolution; Numerical models; Fluid flow measurement; Hemodynamics; magnetic resonance velocimetry (MRV); partial volume effects; phase contrast magnetic resonance imaging (PC-MRI); systematic error; WALL SHEAR-STRESS; PHASE-CONTRAST MRI; IN-VIVO; INTRACRANIAL ANEURYSMS; BLOOD-FLOW; PATTERNS; IMAGES;
D O I
10.1109/TMI.2022.3149421
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We present a model to estimate the bias error of 4D flow magnetic resonance imaging (MRI) velocity measurements. The local instantaneous bias error is defined as the difference between the expectation of the voxel's measured velocity and actual velocity at the voxel center. The model accounts for bias error introduced by the intra-voxel velocity distribution and partial volume (PV) effects. We assess the intra-voxel velocity distribution using a 3D Taylor Series expansion. PV effects and numerical errors are considered using a Richardson extrapolation. The model is applied to synthetic Womersley flow and in vitro and in vivo 4D flow MRI measurements in a cerebral aneurysm. The bias error model is valid for measurements with at least 3.75 voxels across the vessel diameter and signal-to-noise ratio greater than 5. All test cases exceeded this diameter to voxel size ratio with diameters, isotropic voxel sizes, and velocity ranging from 3-15mm, 0.5-1mm, and 0-60cm/s, respectively. The model accurately estimates the bias error in voxels not affected by PV effects. In PV voxels, the bias error is an order of magnitude higher, and the accuracy of the bias error estimation in PV voxels ranges from 67.3% to 108% relative to the actual bias error. The bias error estimated for in vivo measurements increased two-fold at systole compared to diastole in partial volume and non-partial volume voxels, suggesting the bias error varies over the cardiac cycle. This bias error model quantifies 4D flow MRI measurement accuracy and can help plan 4D flow MRI scans.
引用
收藏
页码:1802 / 1812
页数:11
相关论文
共 50 条
  • [41] Editorial for "Aortic Pulse Wave Velocity Evaluated by 4D Flow MRI Across the Adult Lifespan"
    Fyrdahl, Alexander
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 56 (02) : 474 - 475
  • [42] Interpolation time-optimized aortic pulse wave velocity estimation by 4D flow MRI
    Sungho Park
    Minseong Kwon
    Hyojin Nam
    Hyungkyu Huh
    Scientific Reports, 13
  • [43] Intracranial pulse wave velocity using 4D flow MRI: method comparison and covariate analysis
    Dempsey, Sergio
    Safaei, Soroush
    Holdsworth, Samantha J.
    Talou, Gonzalo D. Maso
    INTERFACE FOCUS, 2025, 15 (01)
  • [44] Interpolation time-optimized aortic pulse wave velocity estimation by 4D flow MRI
    Park, Sungho
    Kwon, Minseong
    Nam, Hyojin
    Huh, Hyungkyu
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [45] Comparison of turbulent flow measurement schemes for 4D flow MRI
    Ha, Hoijn
    Park, Hanwook
    JOURNAL OF VISUALIZATION, 2019, 22 (03) : 541 - 553
  • [46] Comparison of turbulent flow measurement schemes for 4D flow MRI
    Hoijn Ha
    Hanwook Park
    Journal of Visualization, 2019, 22 : 541 - 553
  • [47] Error propagation in Gassmann modeling for 4D feasibility studies
    Engelmark, Folke
    Leading Edge (Tulsa, OK), 2002, 21 (10): : 984 - 987
  • [48] 4D FLOW MRI AND LUMPED-PARAMETER MODELING TO ASSESS OF AORTIC VALVE HEMODYNAMICS
    Flores, Julio Garcia
    Barker, Alex
    Markl, Michael
    Thomas, James
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (13) : 2206 - 2206
  • [49] 4D velocity measurements in intracranial aneurysms using 3T phase contrast MRI angiography
    van Ooij, P.
    Schneiders, J. J.
    VanBavel, E.
    Majoie, C. B.
    Nederveen, A. J.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 617 - 620
  • [50] Stochastic 4D Flow Vector-Field Signatures: A New Approach for Comprehensive 4D Flow MRI Quantification
    Elbaz, Mohammed S. M.
    Malaisrie, Chris
    McCarthy, Patrick
    Markl, Michael
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2021, PT V, 2021, 12905 : 215 - 224