Experimental studies on the effect of impeller width on centrifugal compressor stage performance with low solidity vaned diffusers

被引:11
|
作者
Reddy, T. Ch Siva
Murty, G. V. Ramana [1 ]
Prasad, M. V. S. S. S. M.
Reddy, D. N.
机构
[1] Bharat Heavy Elect Ltd, Corp R&D Div, Turbomachinery Lab, Hyderabad 500093, Andhra Pradesh, India
[2] Streenidhi Inst Sci & Technol, Hyderabad, Andhra Pradesh, India
关键词
centrifugal compressor; vaneless diffuser; low solidity vaned diffuser; impeller width; setting angle; performance; flow coefficient; static pressure recovery coefficient;
D O I
10.1243/09576509JPE373
中图分类号
O414.1 [热力学];
学科分类号
摘要
In an effort to improve the performance of centrifugal compressors, detailed studies were carried out on three different impeller-diffuser configurations covering a wide range of design flow coefficients. These were two-dimensional impellers chosen from a multi-stage compressor series with identical blade geometry. The impeller exit widths covered were 24.5, 18.5, and 11.5 mm, respectively. Extensive experimental studies have been carried out on the chosen stage configurations with parallel walled vaneless diffusers (VLDs) as well as low solidity vaned diffuser (LSD). For all the tested configurations, the aerofoil shape of the diffuser vanes remained same while the diffuser width, setting angle, and solidity were chosen as variables. The performance for each of the stages with LSDs was compared with that of the corresponding VLD. Significant improvement in performance in terms of polytropic efficiency, head coefficient, and static pressure recovery coefficient was observed with LSD vanes as compared with the VLD. Significant improvement in performance was noticed from low flow till design point for all the tested cases. The study revealed that among the tested configurations, there is an optimum width at impeller exit and diffuser for which the performance of the stage was the best. Performance in terms of static pressure recovery coefficient was also evaluated for all the tested configurations and compared. All the studies were conducted for solidity ratio of 0.81. The effect of setting angle on wall static pressure coefficient was also studied at 24 degrees and 28 degrees for the flow coefficients corresponding to 80, 100, and 120 per cent of design flow. Flow surveys at impeller exit for the three cases covering impellers/parallel walled diffusers of different widths have also been carried out to know the flow behaviour in the passage between the impeller and the diffuser.
引用
收藏
页码:519 / 533
页数:15
相关论文
共 50 条
  • [31] EFFECT OF FORCED ROTATING VANELESS DIFFUSERS ON CENTRIFUGAL COMPRESSOR STAGE PERFORMANCE
    Govardhan, M.
    Seralathan, S.
    JOURNAL OF ENGINEERING SCIENCE AND TECHNOLOGY, 2011, 6 (05) : 558 - 574
  • [32] Numerical investigation of low solidity vaned diffuser performance in a high-pressure centrifugal compressor - Part 1: Influence of vane solidity
    Oh, JongSik
    Agrawal, Giri L.
    Proceedings of the ASME Turbo Expo 2007, Vol 6, Pts A and B, 2007, : 1009 - 1015
  • [33] Modification of Centrifugal Impeller and Effect of Impeller Extended Shrouds on Centrifugal Compressor Performance
    Seralathan, S.
    Chowdhury, Roy D. G.
    INTERNATIONAL CONFERENCE ON DESIGN AND MANUFACTURING (ICONDM2013), 2013, 64 : 1119 - 1128
  • [34] High Dimensional Matching Optimization of Impeller-Vaned Diffuser Interaction for a Centrifugal Compressor Stage
    Qin, Ruihong
    Ju, Yaping
    Galloway, Lee
    Spence, Stephen
    Zhang, Chuhua
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2020, 142 (12):
  • [35] Numerical investigation of the effect of impeller velocity factor on the performance of centrifugal compressor stage
    School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an 710049, China
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2008, 42 (07): : 807 - 810
  • [36] Performance improvement of a centrifugal compressor by a variable low solidity diffuser
    Zuo, Shu-Guang (sgzuo@tongji.edu), 1600, Science Press (38):
  • [37] NUMERICAL INVESTIGATION OF LOW SOLIDITY VANED DIFFUSER PERFORMANCE IN A HIGH-PRESSURE CENTRIFUGAL COMPRESSOR PART III : TANDEM VANES
    Oh, JongSik
    Buckley, Charles W.
    Agrawal, Giri L.
    PROCEEDINGS OF THE ASME TURBO EXPO 2011, VOL 7, PTS A-C, 2012, : 1947 - 1955
  • [38] Results of Investigation of a Centrifugal Compressor Stage with an Increased Impeller Wheel Width.
    Evdokimov, V.E.
    Naroditskii, B.I.
    Energomashinostroenie, 1981, (06): : 12 - 17
  • [39] EFFECT OF CAVITIES ON IMPELLER AEROMECHANICAL FORCING IN A LOW PRESSURE RATIO CENTRIFUGAL COMPRESSOR STAGE
    Clancy, Cathal
    Moyroud, Francois
    Ramakrishnan, Kishore
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2014, VOL 2D, 2014,
  • [40] AN EXPERIMENTAL INVESTIGATION ON THE CLOCKING EFFECT BETWEEN INLET GUIDE VANES AND VANED DIFFUSER IN A CENTRIFUGAL COMPRESSOR STAGE
    Jiang Hua
    Xi Guang
    Zhang Wei
    Gong Wuqi
    Wang ZhiHeng
    IMECE 2008: PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, VOL 5, 2009, : 67 - 74