Experimental studies on the effect of impeller width on centrifugal compressor stage performance with low solidity vaned diffusers

被引:11
|
作者
Reddy, T. Ch Siva
Murty, G. V. Ramana [1 ]
Prasad, M. V. S. S. S. M.
Reddy, D. N.
机构
[1] Bharat Heavy Elect Ltd, Corp R&D Div, Turbomachinery Lab, Hyderabad 500093, Andhra Pradesh, India
[2] Streenidhi Inst Sci & Technol, Hyderabad, Andhra Pradesh, India
关键词
centrifugal compressor; vaneless diffuser; low solidity vaned diffuser; impeller width; setting angle; performance; flow coefficient; static pressure recovery coefficient;
D O I
10.1243/09576509JPE373
中图分类号
O414.1 [热力学];
学科分类号
摘要
In an effort to improve the performance of centrifugal compressors, detailed studies were carried out on three different impeller-diffuser configurations covering a wide range of design flow coefficients. These were two-dimensional impellers chosen from a multi-stage compressor series with identical blade geometry. The impeller exit widths covered were 24.5, 18.5, and 11.5 mm, respectively. Extensive experimental studies have been carried out on the chosen stage configurations with parallel walled vaneless diffusers (VLDs) as well as low solidity vaned diffuser (LSD). For all the tested configurations, the aerofoil shape of the diffuser vanes remained same while the diffuser width, setting angle, and solidity were chosen as variables. The performance for each of the stages with LSDs was compared with that of the corresponding VLD. Significant improvement in performance in terms of polytropic efficiency, head coefficient, and static pressure recovery coefficient was observed with LSD vanes as compared with the VLD. Significant improvement in performance was noticed from low flow till design point for all the tested cases. The study revealed that among the tested configurations, there is an optimum width at impeller exit and diffuser for which the performance of the stage was the best. Performance in terms of static pressure recovery coefficient was also evaluated for all the tested configurations and compared. All the studies were conducted for solidity ratio of 0.81. The effect of setting angle on wall static pressure coefficient was also studied at 24 degrees and 28 degrees for the flow coefficients corresponding to 80, 100, and 120 per cent of design flow. Flow surveys at impeller exit for the three cases covering impellers/parallel walled diffusers of different widths have also been carried out to know the flow behaviour in the passage between the impeller and the diffuser.
引用
收藏
页码:519 / 533
页数:15
相关论文
共 50 条
  • [11] Effect of high negative incidence on the performance of a centrifugal compressor stage with conventional vaned diffusers
    Ahti Jaatinen
    Aki Grnman
    Teemu Turunen-Saaresti
    Jari Backman
    Journal of Thermal Science, 2011, 20 (02) : 97 - 105
  • [12] Effect of high negative incidence on the performance of a centrifugal compressor stage with conventional vaned diffusers
    Jaatinen, Ahti
    Gronman, Aki
    Turunen-Saaresti, Teemu
    Backman, Jari
    JOURNAL OF THERMAL SCIENCE, 2011, 20 (02) : 97 - 105
  • [13] Experimental Study on Effects of Adjustable Vaned Diffusers on Impeller Backside Cavity of Centrifugal Compressor in CAES
    Lin, Zhihua
    Zuo, Zhitao
    Guo, Wenbin
    Sun, Jianting
    Liang, Qi
    Chen, Haisheng
    ENERGIES, 2021, 14 (19)
  • [14] AERODYNAMIC PERFORMANCE OF A CENTRIFUGAL-COMPRESSOR WITH VANED DIFFUSERS
    YOSHINAGA, Y
    GYOBU, I
    MISHINA, H
    KOSEKI, F
    NISHIDA, H
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 1980, 102 (04): : 486 - 493
  • [15] Performance improvement of a centrifugal compressor using partial vaned diffusers
    Gunadal S.M.
    Govardhan M.
    Gunadal, S.M. (smgunadal@me.vjti.ac.in), 1600, Turbomachinery Society of Japan (13): : 177 - 189
  • [16] Aerodynamic Performance and Noise Characteristics of a Centrifugal Compressor with Modified Vaned Diffusers
    Ohta, Yutaka
    Okutsu, Yasuhiko
    Goto, Takashi
    Outa, Eisuke
    JOURNAL OF THERMAL SCIENCE, 2006, 15 (04) : 289 - 295
  • [17] EXPERIMENTAL AND NUMERICAL INVESTIGATION OF VANED HUB AND SHROUD WALL CONTOURED DIFFUSERS DESIGNED TO IMPROVE FLEXIBILITY AND EFFICIENCY OF AN OPEN IMPELLER CENTRIFUGAL COMPRESSOR STAGE
    Hermann, Daniel
    Wirsum, Manfred
    Robinson, Douglas
    Jenny, Philipp
    PROCEEDINGS OF ASME TURBO EXPO 2021: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, VOL 2D, 2021,
  • [18] Experimental investigations on pressure fluctuations and vibration of the impeller in a centrifugal pump with vaned diffusers
    Guo, SJ
    Maruta, Y
    JSME INTERNATIONAL JOURNAL SERIES B-FLUIDS AND THERMAL ENGINEERING, 2005, 48 (01) : 136 - 143
  • [19] Aerodynamic performance and noise characteristics of a centrifugal compressor with modified vaned diffusers
    Yutaka Ohta
    Yasuhiko Okutsu
    Takashi Goto
    Eisuke Outa
    Journal of Thermal Science, 2006, 15 : 289 - 295
  • [20] Aerodynamic Performance and Noise Characteristics of a Centrifugal Compressor with Modified Vaned Diffusers
    YutakaOHTA
    YasuhikoOKUTSU
    TakashiGOTO
    EisukeOUTA
    Journal of Thermal Science, 2006, (04) : 289 - 295