AN EXPERIMENTAL INVESTIGATION ON THE CLOCKING EFFECT BETWEEN INLET GUIDE VANES AND VANED DIFFUSER IN A CENTRIFUGAL COMPRESSOR STAGE

被引:0
|
作者
Jiang Hua [1 ]
Xi Guang [1 ]
Zhang Wei [1 ]
Gong Wuqi [1 ]
Wang ZhiHeng [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Xian 710049, Peoples R China
关键词
ROTOR-STATOR INTERACTIONS; SPEED AXIAL COMPRESSOR; AIRFOIL CLOCKING;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Different circumferential angle positions between stator or rotor vane rows in turbomachinery can lead to different flow structures or stage performances. The clocking effect phenomenon has been detected in axial compressor and turbine by investigators, but rarely reported on centrifugal compressor. The present work is an experimental investigation on the stator clocking effect between inlet guide vanes (IGV) and vaned diffuser in a low-speed centrifugal compressor. The experimental rig consists of a circumferentially rotatable IGV, an unshrouded centrifugal impeller, a vaned diffuser, a volute and etc. The impeller diameter is 796mm, and the rotate speed is about 3100 rpm. At each inlet prewhirl angle of -20 degrees, 0 degrees and +20 degrees, the stage performance curves are measured at three clocking angle positions of 0 degrees, 8 degrees and 16 degrees. The result shows that at the circumferential angles of 0 degrees and 8 degrees, the efficiency curve has a double peak value feature, but at the angle of 16 degrees being the conventional single peak value curve. Further, at the circumferential angles of 0 degrees and 8 degrees, the stage efficiency is bigger 3.6% than that case of the angle being 16 degrees, where the IGV prewhirl angles are 0 degrees and 20 degrees. When the IGV prewhirl angle is changed into -20 degrees, the stage efficiency increases about 2.0% near the first peak value position at the circumferential angles of Wand 8 degrees than at 16 degrees, however, at the second peak value position, the stage efficiency at the circumferential angle of 0 degrees is bigger about 1.4% than at 8 degrees and 16 degrees. Moreover, the circumferential angle positions between IGV and vaned diffuser have corresponding influence on the pressure ratio.
引用
下载
收藏
页码:67 / 74
页数:8
相关论文
共 50 条
  • [1] DESIGN OF A SINGLE-STAGE CENTRIFUGAL COMPRESSOR AND NUMERICAL INVESTIGATION OF SIMULTANEOUS ADJUSTMENT OF INLET GUIDE VANES AND DIFFUSER VANES
    Ni, Qifeng
    Hou, Anping
    Tian, Ye
    Xu, Quanyong
    Liu, Enlai
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2013, VOL 6A, 2014,
  • [2] Numerical investigation of clocking effect on a centrifugal pump with inlet guide vanes
    Qu, Wanshi
    Tan, Lei
    Cao, Shuliang
    Wang, Yuchuan
    Xu, Yun
    ENGINEERING COMPUTATIONS, 2016, 33 (02) : 465 - 481
  • [3] Clocking effect under different inlet guide vanes prewhirl angles in a centrifugal compressor
    Jiang, Hua
    Xi, Guang
    Gong, Wuqi
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2010, 44 (07): : 120 - 124
  • [4] Clocking effect in a centrifugal pump with a vaned diffuser
    Lai, Fen
    Zhu, Xiangyuan
    Duan, Yongqiang
    Li, Guojun
    MODERN PHYSICS LETTERS B, 2020, 34 (26):
  • [5] Numerical and experimental investigation of the efficiency of vaned diffuser of centrifugal compressor
    Obukhov, O.
    Smirnov, A.
    Gysak, O.
    8TH INTERNATIONAL CONFERENCE ON COMPRESSORS AND THEIR SYSTEMS, 2013, : 649 - +
  • [6] Experimental investigation on clocking effect of vaned diffuser on performance characteristics and pressure pulsations in a centrifugal pump
    Wang, Wenjie
    Pei, Ji
    Yuan, Shouqi
    Yin, Tingyun
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2018, 90 : 286 - 298
  • [7] Effect of inlet guide vanes on centrifugal compressor acoustics and performance
    Figurella, Neil
    Dehner, Rick
    Selamet, Ahmet
    Tallio, Kevin
    Miazgowicz, Keith
    Wade, Robert
    Karim, Ahsanul
    Keller, Philip
    Shutty, John
    NOISE CONTROL ENGINEERING JOURNAL, 2014, 62 (04) : 232 - 237
  • [8] Experimental investigation of surge and stall in a turbocharger centrifugal compressor with a vaned diffuser
    Zheng, Xinqian
    Sun, Zhenzhong
    Kawakubo, Tomoki
    Tamaki, Hideaki
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2017, 82 : 493 - 506
  • [9] THE EFFECTS OF RADIAL INLET ON THE PERFORMANCE OF VARIABLE INLET GUIDE VANES IN A CENTRIFUGAL COMPRESSOR STAGE
    Tan, Jiajian
    Qi, Datong
    Wang, Rui
    PROCEEDINGS OF THE ASME TURBO EXPO 2010: TURBOMACHINERY: AXIAL FLOW FAN AND COMPRESSOR AERODYNAMICS DESIGN METHODS, AND CFD MODELING FOR TURBOMACHINERY, VOL 7, PTS A-C, 2010, : 1723 - 1732
  • [10] An Investigation of Stall Inception in Centrifugal Compressor Vaned Diffuser
    Everitt, Jonathan N.
    Spakovszky, Zoltan S.
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2013, 135 (01):