Simultaneous and rapid quantitation of benazepril and benazeprilat in human plasma by high performance liquid chromatography with ultraviolet detection

被引:11
|
作者
Wang, Xue-Ding
Chan, Eli
Chen, Xiao
Liao, Xiao-Xing
Tang, Cheng
Zhou, Zhi-Wei
Huang, Min
Zhou, Shu-Feng
机构
[1] Australian Inst Chinese Med, Dept Pharmacol & Toxicol, Inst Clin Pharmacol, Guangzhou 510090, Peoples R China
[2] Natl Univ Singapore, Dept Pharm, Singapore 117548, Singapore
[3] Sun Yat Sen Univ, Affiliated Hosp, Dept Pharm, Guangzhou, Peoples R China
[4] Sun Yat Sen Univ, Affiliated Hosp, Dept Emergency Med, Guangzhou, Peoples R China
[5] Nanchang Univ, Sch Bioengn, Nanchang, Peoples R China
[6] Australian Inst Chinese Med, Dept Pharmacol & Toxicol, Brisbane, Qld 2118, Australia
[7] Queensland Univ Technol, Sch Life Sci, Brisbane, Qld 4001, Australia
基金
中国国家自然科学基金;
关键词
benazepril; benazeprilat; HPLC; human; bioequivalence; C-max; AUC; tablet;
D O I
10.1016/j.jpba.2007.01.009
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive and accurate high-performance liquid chromatography (HPLC) method with ultraviolet (UV) detector was developed and validated for simultaneous determination of benazepril (BZL) and its active metabolite, benazeprilat (BZT), in human plasma. The plasma sample, after spiked with riluzole as an internal standard (IS), was subjected to a solid-phase extraction (SPE) prior to a HPLC analysis. Chromatographic separations were achieved on a Hypersil BDS C-18 (300 mm x 4.6 mm, 5 mu m). The mobile phase consisted of phosphate buffer (pH 2.6; 10 mM) and acetonitrile mixture in a gradient mode. Detection was carried out at a wavelength of 237 nm. The retention times of BZL, BZT and IS were at about 6.2, 15.4 and 16.2 min, respectively. The calibration curve was linear in the range of 20-2000 ng/mL for both BZL and BZT (r(2) > 0.997). At three quality control concentrations of 100, 500, and 1500 ng/mL, the intra-day and inter-day relative standard deviation ranged from 2.8 to 8.6% for BZL and from 2.2 to 8.5% for BZT, while the mean absolute percentage error ranged from -7.5 to 6.7% for BZL and from -6.0 to 3.2% for BZT. The limit of detection (LOD) was 10 ng/mL and the limit of quantification (LOQ) was 20 ng/mL for both BZL and BZT in human plasma. The method was successfully applied to bioequivalence evaluation of benazepril hydrochloride formulations in healthy Chinese. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:224 / 230
页数:7
相关论文
共 50 条
  • [41] Simultaneous determination of quinapril and its active metabolite quinaprilat in human plasma using high-performance liquid chromatography with ultraviolet detection
    Abbara, C
    Aymard, G
    Hinh, S
    Diquet, B
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 766 (02): : 199 - 207
  • [42] A simple and rapid method for detection of paraquat in human plasma by high-performance liquid chromatography
    Sun, Bin
    Chen, Yuguo
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (10): : 17067 - 17071
  • [43] Simple, rapid and sensitive method for the determination of indomethacin in plasma by high-performance liquid chromatography with ultraviolet detection
    Sato, J
    Amizuka, T
    Niida, Y
    Umetsu, M
    Ito, K
    JOURNAL OF CHROMATOGRAPHY B, 1997, 692 (01): : 241 - 244
  • [44] Analysis of plasma thiols by high-performance liquid chromatography with ultraviolet detection
    Bald, E
    Chwatko, G
    Glowacki, R
    Kusmierek, K
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1032 (1-2) : 109 - 115
  • [45] Quantification of doripenem in human plasma and peritoneal fluid by high-performance liquid chromatography with ultraviolet detection
    Ikeda, Kayo
    Ikawa, Kazuro
    Morikawa, Norifumi
    Kameda, Keiko
    Urakawa, Nami
    Ohge, Hiroki
    Sueda, Taijiro
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 867 (01): : 20 - 25
  • [46] DETERMINATION OF TICLOPIDINE IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND ULTRAVIOLET ABSORBENCY DETECTION
    DALBO, L
    VERGA, F
    MARZO, A
    AMBROSOLI, L
    POLI, A
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1995, 665 (02): : 404 - 409
  • [48] DETERMINATION OF AMPICILLIN IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING ULTRAVIOLET DETECTION
    AKHTAR, MJ
    KHAN, S
    KHAN, MAS
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (4-5) : 375 - 378
  • [49] Trace analysis of tobramycin in human plasma by derivatization and high-performance liquid chromatography with ultraviolet detection
    Feng, CH
    Lin, SJ
    Wu, HL
    Chen, SH
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 780 (02): : 349 - 354
  • [50] Determination of cisapride and norcisapride in human plasma using high-performance liquid chromatography with ultraviolet detection
    Cisternino, S
    Schlatter, J
    Saulnier, JL
    JOURNAL OF CHROMATOGRAPHY B, 1998, 714 (02): : 395 - 398