Simultaneous and rapid quantitation of benazepril and benazeprilat in human plasma by high performance liquid chromatography with ultraviolet detection

被引:11
|
作者
Wang, Xue-Ding
Chan, Eli
Chen, Xiao
Liao, Xiao-Xing
Tang, Cheng
Zhou, Zhi-Wei
Huang, Min
Zhou, Shu-Feng
机构
[1] Australian Inst Chinese Med, Dept Pharmacol & Toxicol, Inst Clin Pharmacol, Guangzhou 510090, Peoples R China
[2] Natl Univ Singapore, Dept Pharm, Singapore 117548, Singapore
[3] Sun Yat Sen Univ, Affiliated Hosp, Dept Pharm, Guangzhou, Peoples R China
[4] Sun Yat Sen Univ, Affiliated Hosp, Dept Emergency Med, Guangzhou, Peoples R China
[5] Nanchang Univ, Sch Bioengn, Nanchang, Peoples R China
[6] Australian Inst Chinese Med, Dept Pharmacol & Toxicol, Brisbane, Qld 2118, Australia
[7] Queensland Univ Technol, Sch Life Sci, Brisbane, Qld 4001, Australia
基金
中国国家自然科学基金;
关键词
benazepril; benazeprilat; HPLC; human; bioequivalence; C-max; AUC; tablet;
D O I
10.1016/j.jpba.2007.01.009
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive and accurate high-performance liquid chromatography (HPLC) method with ultraviolet (UV) detector was developed and validated for simultaneous determination of benazepril (BZL) and its active metabolite, benazeprilat (BZT), in human plasma. The plasma sample, after spiked with riluzole as an internal standard (IS), was subjected to a solid-phase extraction (SPE) prior to a HPLC analysis. Chromatographic separations were achieved on a Hypersil BDS C-18 (300 mm x 4.6 mm, 5 mu m). The mobile phase consisted of phosphate buffer (pH 2.6; 10 mM) and acetonitrile mixture in a gradient mode. Detection was carried out at a wavelength of 237 nm. The retention times of BZL, BZT and IS were at about 6.2, 15.4 and 16.2 min, respectively. The calibration curve was linear in the range of 20-2000 ng/mL for both BZL and BZT (r(2) > 0.997). At three quality control concentrations of 100, 500, and 1500 ng/mL, the intra-day and inter-day relative standard deviation ranged from 2.8 to 8.6% for BZL and from 2.2 to 8.5% for BZT, while the mean absolute percentage error ranged from -7.5 to 6.7% for BZL and from -6.0 to 3.2% for BZT. The limit of detection (LOD) was 10 ng/mL and the limit of quantification (LOQ) was 20 ng/mL for both BZL and BZT in human plasma. The method was successfully applied to bioequivalence evaluation of benazepril hydrochloride formulations in healthy Chinese. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:224 / 230
页数:7
相关论文
共 50 条
  • [31] Quantitative Determination of Imatinib in Human Plasma with High-Performance Liquid Chromatography and Ultraviolet Detection
    Miura, Masatomo
    Takahashi, Naoto
    Sawada, Ken-ichi
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2011, 49 (05) : 412 - 415
  • [32] DETERMINATION OF VINCAMINE IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ULTRAVIOLET DETECTION
    DALBO, L
    CERIANI, G
    BROCCALI, G
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 573 (01): : 158 - 162
  • [33] RAPID SIMULTANEOUS DETERMINATION OF NITRATE AND NITRITE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING ULTRAVIOLET DETECTION
    GERRITSE, RG
    JOURNAL OF CHROMATOGRAPHY, 1979, 171 (APR): : 527 - 529
  • [34] Quantitation of zopiclone and desmethylzopiclone in human plasma by high-performance liquid chromatography using fluorescence detection
    Nirogi, Ramakrishna V. S.
    Kandikere, Vishwottam N.
    Mudigonda, Koteshwara
    BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (08) : 794 - 799
  • [35] QUANTITATION OF OXYCODONE IN HUMAN PLASMA USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION
    SMITH, MT
    WATT, JA
    MAPP, GP
    CRAMOND, T
    THERAPEUTIC DRUG MONITORING, 1991, 13 (02) : 126 - 130
  • [36] Simultaneous analysis of multiple aminothiols in human plasma by high performance liquid chromatography with fluorescence detection
    McMenamin, M. Elizabeth
    Himmelfarb, Jonathan
    Nolin, Thomas D.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (28): : 3274 - 3281
  • [37] Quantitation of clobazam in human plasma using high-performance liquid chromatography
    Knapp, J
    Bokník, P
    Gumbinger, HG
    Linck, B
    Lüss, H
    Müller, FU
    Schmitz, W
    Vahlensieck, U
    Neumann, J
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1999, 37 (05) : 145 - 149
  • [38] Quantitation of atorvastatin in human plasma using directly suspended acceptor droplet in liquid-liquid-liquid microextraction and high-performance liquid chromatography-ultraviolet detection
    Farahani, Hadi
    Norouzi, Parviz
    Beheshti, Abolghasem
    Sobhi, Hamid Reza
    Dinarvand, Rasoul
    Ganjali, Mohammad Reza
    TALANTA, 2009, 80 (02) : 1001 - 1006
  • [39] Simultaneous quantification of levofloxacin, pefloxacin, ciprofloxacin and moxifloxacin in microvolumes of human plasma using high-performance liquid chromatography with ultraviolet detection
    Zheng, Yi
    Wang, Ziqing
    Lui, Gabrielle
    Hirt, Deborah
    Treluyer, Jean-Marc
    Benaboud, Sihem
    Aboura, Radia
    Gana, Ines
    BIOMEDICAL CHROMATOGRAPHY, 2019, 33 (05)
  • [40] Simultaneous determination of clozapine, norclozapine and clozapine-N-oxide in human plasma by high-performance liquid chromatography with ultraviolet detection
    Liu, YY
    van Troostwijk, LJAED
    Guchelaar, HJ
    BIOMEDICAL CHROMATOGRAPHY, 2001, 15 (04) : 280 - 286