Simultaneous and rapid quantitation of benazepril and benazeprilat in human plasma by high performance liquid chromatography with ultraviolet detection

被引:11
|
作者
Wang, Xue-Ding
Chan, Eli
Chen, Xiao
Liao, Xiao-Xing
Tang, Cheng
Zhou, Zhi-Wei
Huang, Min
Zhou, Shu-Feng
机构
[1] Australian Inst Chinese Med, Dept Pharmacol & Toxicol, Inst Clin Pharmacol, Guangzhou 510090, Peoples R China
[2] Natl Univ Singapore, Dept Pharm, Singapore 117548, Singapore
[3] Sun Yat Sen Univ, Affiliated Hosp, Dept Pharm, Guangzhou, Peoples R China
[4] Sun Yat Sen Univ, Affiliated Hosp, Dept Emergency Med, Guangzhou, Peoples R China
[5] Nanchang Univ, Sch Bioengn, Nanchang, Peoples R China
[6] Australian Inst Chinese Med, Dept Pharmacol & Toxicol, Brisbane, Qld 2118, Australia
[7] Queensland Univ Technol, Sch Life Sci, Brisbane, Qld 4001, Australia
基金
中国国家自然科学基金;
关键词
benazepril; benazeprilat; HPLC; human; bioequivalence; C-max; AUC; tablet;
D O I
10.1016/j.jpba.2007.01.009
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive and accurate high-performance liquid chromatography (HPLC) method with ultraviolet (UV) detector was developed and validated for simultaneous determination of benazepril (BZL) and its active metabolite, benazeprilat (BZT), in human plasma. The plasma sample, after spiked with riluzole as an internal standard (IS), was subjected to a solid-phase extraction (SPE) prior to a HPLC analysis. Chromatographic separations were achieved on a Hypersil BDS C-18 (300 mm x 4.6 mm, 5 mu m). The mobile phase consisted of phosphate buffer (pH 2.6; 10 mM) and acetonitrile mixture in a gradient mode. Detection was carried out at a wavelength of 237 nm. The retention times of BZL, BZT and IS were at about 6.2, 15.4 and 16.2 min, respectively. The calibration curve was linear in the range of 20-2000 ng/mL for both BZL and BZT (r(2) > 0.997). At three quality control concentrations of 100, 500, and 1500 ng/mL, the intra-day and inter-day relative standard deviation ranged from 2.8 to 8.6% for BZL and from 2.2 to 8.5% for BZT, while the mean absolute percentage error ranged from -7.5 to 6.7% for BZL and from -6.0 to 3.2% for BZT. The limit of detection (LOD) was 10 ng/mL and the limit of quantification (LOQ) was 20 ng/mL for both BZL and BZT in human plasma. The method was successfully applied to bioequivalence evaluation of benazepril hydrochloride formulations in healthy Chinese. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:224 / 230
页数:7
相关论文
共 50 条
  • [21] Simultaneous determination of five antipsychotic drugs in rat plasma by high performance liquid chromatography with ultraviolet detection
    Zhang, Guodong
    Terry, Alvin V., Jr.
    Bartlett, Michael G.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 856 (1-2): : 20 - 28
  • [22] Simultaneous determination of five systemic azoles in plasma by high-performance liquid chromatography with ultraviolet detection
    Gordien, Jean-Baptiste
    Pigneux, Arnaud
    Vigouroux, Stephane
    Tabrizi, Reza
    Accoceberry, Isabelle
    Bernadou, Jean-Marc
    Rouault, Audrey
    Saux, Marie-Claude
    Breilh, Dominique
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 50 (05) : 932 - 938
  • [23] Rapid and simultaneous determination of sulfamethoxazole and trimethoprim in human plasma by high-performance liquid chromatography
    Amini, Hossein
    Ahmadiani, Abolhassan
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (03) : 1146 - 1150
  • [24] Simultaneous Estimation of Saxagliptin and Dapagliflozin in Human Plasma by Validated High Performance Liquid Chromatography - Ultraviolet Method
    Donepudi, Sharmila
    Achanta, Suneetha
    TURKISH JOURNAL OF PHARMACEUTICAL SCIENCES, 2019, 16 (02) : 227 - 233
  • [25] SIMULTANEOUS QUANTITATION OF THIOUREAS IN RAT PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    KOBAYASHI, H
    MATANO, O
    GOTO, S
    JOURNAL OF CHROMATOGRAPHY, 1981, 207 (02): : 281 - 285
  • [26] Simultaneous quantitation of plasma doxorubicin and prochlorperazine content by high-performance liquid chromatography
    Mou, CH
    Ganju, N
    Sridhar, KS
    Krishan, A
    JOURNAL OF CHROMATOGRAPHY B, 1997, 703 (1-2): : 217 - 224
  • [27] DETERMINATION OF AMRINONE IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ULTRAVIOLET DETECTION
    BANSAL, R
    LOURIDAS, AT
    GOTTESMAN, RD
    ARANDA, JV
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1994, 17 (16): : 3531 - 3539
  • [28] A high-performance liquid chromatography assay with ultraviolet detection for olanzapine in human plasma and urine
    Boulton, DW
    Markowitz, JS
    DeVane, CL
    JOURNAL OF CHROMATOGRAPHY B, 2001, 759 (02): : 319 - 323
  • [29] Determination of lipoic acid in human plasma by high-performance liquid chromatography with ultraviolet detection
    Chwatko, Grazyna
    Krawczyk, Marta
    Iciek, Malgorzata
    Kaminska, Adrianna
    Bilska-Wilkosz, Anna
    Marcykiewicz, Bernadeta
    Glowacki, Rafal
    ARABIAN JOURNAL OF CHEMISTRY, 2019, 12 (08) : 4878 - 4886
  • [30] Clozapine and norclozapine quantification in human plasma by high-performance liquid chromatography with ultraviolet detection
    Illamola, S. M.
    Perez, A. A.
    Morillas, M. G.
    Fresquet, X. S.
    Barreda, F. C.
    THERAPEUTIC DRUG MONITORING, 2011, 33 (04) : 525 - 525