Simultaneous and rapid quantitation of benazepril and benazeprilat in human plasma by high performance liquid chromatography with ultraviolet detection

被引:11
|
作者
Wang, Xue-Ding
Chan, Eli
Chen, Xiao
Liao, Xiao-Xing
Tang, Cheng
Zhou, Zhi-Wei
Huang, Min
Zhou, Shu-Feng
机构
[1] Australian Inst Chinese Med, Dept Pharmacol & Toxicol, Inst Clin Pharmacol, Guangzhou 510090, Peoples R China
[2] Natl Univ Singapore, Dept Pharm, Singapore 117548, Singapore
[3] Sun Yat Sen Univ, Affiliated Hosp, Dept Pharm, Guangzhou, Peoples R China
[4] Sun Yat Sen Univ, Affiliated Hosp, Dept Emergency Med, Guangzhou, Peoples R China
[5] Nanchang Univ, Sch Bioengn, Nanchang, Peoples R China
[6] Australian Inst Chinese Med, Dept Pharmacol & Toxicol, Brisbane, Qld 2118, Australia
[7] Queensland Univ Technol, Sch Life Sci, Brisbane, Qld 4001, Australia
基金
中国国家自然科学基金;
关键词
benazepril; benazeprilat; HPLC; human; bioequivalence; C-max; AUC; tablet;
D O I
10.1016/j.jpba.2007.01.009
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive and accurate high-performance liquid chromatography (HPLC) method with ultraviolet (UV) detector was developed and validated for simultaneous determination of benazepril (BZL) and its active metabolite, benazeprilat (BZT), in human plasma. The plasma sample, after spiked with riluzole as an internal standard (IS), was subjected to a solid-phase extraction (SPE) prior to a HPLC analysis. Chromatographic separations were achieved on a Hypersil BDS C-18 (300 mm x 4.6 mm, 5 mu m). The mobile phase consisted of phosphate buffer (pH 2.6; 10 mM) and acetonitrile mixture in a gradient mode. Detection was carried out at a wavelength of 237 nm. The retention times of BZL, BZT and IS were at about 6.2, 15.4 and 16.2 min, respectively. The calibration curve was linear in the range of 20-2000 ng/mL for both BZL and BZT (r(2) > 0.997). At three quality control concentrations of 100, 500, and 1500 ng/mL, the intra-day and inter-day relative standard deviation ranged from 2.8 to 8.6% for BZL and from 2.2 to 8.5% for BZT, while the mean absolute percentage error ranged from -7.5 to 6.7% for BZL and from -6.0 to 3.2% for BZT. The limit of detection (LOD) was 10 ng/mL and the limit of quantification (LOQ) was 20 ng/mL for both BZL and BZT in human plasma. The method was successfully applied to bioequivalence evaluation of benazepril hydrochloride formulations in healthy Chinese. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:224 / 230
页数:7
相关论文
共 50 条
  • [1] Simultaneous determination of benazepril hydrochloride and benazeprilat in plasma by high-performance liquid chromatography/electrospray-mass spectrometry
    Xiao, WT
    Chen, B
    Yao, SZ
    Cheng, Z
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 814 (02): : 303 - 308
  • [2] Quantitation of Venetoclax in Human Plasma by High-Performance Liquid Chromatography with Ultraviolet Detection
    Fukuda, Natsuki
    Kobayashi, Takahiro
    Sato, Honami
    Akamine, Yumiko
    Takahashi, Naoto
    Miura, Masatomo
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2024, 62 (01) : 58 - 64
  • [3] Rapid quantification of indinavir in human plasma by high-performance liquid chromatography with ultraviolet detection
    Foisy, ML
    Sommadossi, JP
    JOURNAL OF CHROMATOGRAPHY B, 1999, 721 (02): : 239 - 247
  • [4] A high-performance liquid chromatography method using ultraviolet detection for the quantitation of flavopiridol from human plasma
    Zhai, SP
    Sausville, E
    Figg, WD
    BIOMEDICAL CHROMATOGRAPHY, 2002, 16 (06) : 379 - 382
  • [5] Quantitation of Valdecoxib in human plasma by high-performance liquid chromatography with ultraviolet absorbance detection using liquid-liquid extraction
    Ramakrishna, NVS
    Vishwottam, KN
    Wishu, S
    Koteshwara, A
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 802 (02): : 271 - 275
  • [6] Rapid and sensitive quantitation of the antiproliferative agent mitoguazone in small volumes of plasma by high-performance liquid chromatography with ultraviolet detection
    Cheng, CL
    Lin, EG
    Chou, CH
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 793 (02): : 281 - 289
  • [7] Rapid and selective analysis of secnidazole in human plasma using high-performance liquid chromatography with ultraviolet detection
    Ravi, SK
    Naidu, MUR
    Sekhar, EC
    Rao, TRK
    Shobha, JC
    Rani, PU
    Surya, KJ
    JOURNAL OF CHROMATOGRAPHY B, 1997, 691 (01): : 208 - 211
  • [8] Rapid quantitation of (-)-2'-deoxy-3'-thiacytidine in human serum by high-performance liquid chromatography with ultraviolet detection
    Zhou, XJ
    Sommadossi, JP
    JOURNAL OF CHROMATOGRAPHY B, 1997, 691 (02): : 417 - 424
  • [9] Rapid quantitation of free fatty acids in human plasma by high-performance liquid chromatography
    Mehta, A
    Oeser, AM
    Carlson, MG
    JOURNAL OF CHROMATOGRAPHY B, 1998, 719 (1-2): : 9 - 23
  • [10] Quantitation of nimesulide in human plasma by high-performance liquid chromatography with ultraviolet absorbance detection and its application to a bioequivalence study
    Bueno Rolim, Clarice Madalena
    Porta, Valentina
    Storpirtis, Silvia
    ARZNEIMITTELFORSCHUNG-DRUG RESEARCH, 2007, 57 (08): : 537 - +