A cryogenic current comparator (CCC) bridge for quantum Hall resistance ratio measurement has been constructed. Compared to previous CCC systems at the National Physical Laboratory, UK, the new system differs in two aspects. Firstly, it uses a type-II CCC, i.e. the ratio windings are on the outside and the detection winding is on the inside. This has the advantage that the CCC can be made very compact and fits into a standard storage Dewar. Secondly, the bridge electronics uses a digital servo and the SQUID feedback loop is disabled during current reversals. The overall relative measurement uncertainty of the system is of the order of 10(-9).
引用
收藏
页码:302 / 304
页数:3
相关论文
共 50 条
  • [41] DC SUPERCONDUCTING QUANTUM INTERFERENCE DEVICE MAGNETOMETER FOR CRYOGENIC CURRENT COMPARATOR
    NAKANISHI, M
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1994, 33 (10): : 5713 - 5717
  • [42] DC superconducting quantum interference device magnetometer for cryogenic current comparator
    Nakanishi, Masakazu
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 1994, 33 (10): : 5713 - 5717
  • [43] Ultimate current resolution of a cryogenic current comparator
    Sesé, J
    Camón, A
    Rillo, C
    Rietveld, G
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1999, 48 (06) : 1306 - 1313
  • [44] CRYOGENIC CURRENT COMPARATOR WITH INCREASED RESOLUTION
    VANDERWEL, W
    MOOIJ, JE
    HARMANS, CJPM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (04): : 624 - 626
  • [45] Cryogenic current comparator implementation at CENAM
    Sánchez, C
    Avilés, D
    Hernández, D
    Durán, G
    2000 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2000, : 96 - 97
  • [46] Quantum metrological triangle experiment at LNE: measurements on a three-junction R-pump using a 20 000:1 winding ratio cryogenic current comparator
    Devoille, L.
    Feltin, N.
    Steck, B.
    Chenaud, B.
    Sassine, S.
    Djordevic, S.
    Seron, O.
    Piquemal, F.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2012, 23 (12)
  • [47] A quantum Hall effect Kelvin bridge for resistance calibration
    Marzano, Martina
    Callegaro, Luca
    Ortolano, Massimo
    2018 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2018), 2018,
  • [48] LEAKAGE CURRENT DETECTION IN CRYOGENIC CURRENT COMPARATOR BRIDGES
    ELMQUIST, RE
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1993, 42 (02) : 167 - 169
  • [49] CURRENT DISTRIBUTION AND HALL RESISTANCE IN QUANTUM WIRES
    AKERA, H
    ANDO, T
    SURFACE SCIENCE, 1990, 229 (1-3) : 268 - 270
  • [50] AccuBridge™ TOWARDS THE DEVELOPMENT OF A DC CURRENT COMPARATOR RESISTANCE RATIO STANDARD
    Brown, Duane
    Wachowicz, Andrew
    Huang, Shiping
    2010 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS CPEM, 2010, : 639 - +