Cryogenic current comparator bridge for quantum Hall resistance ratio measurements

被引:8
|
作者
Kleinschmidt, P [1 ]
Williams, JM [1 ]
Fletcher, NE [1 ]
Janssen, TJBM [1 ]
机构
[1] Natl Phys Lab, Teddington TW11 0LW, Middx, England
关键词
Bridge circuits - Cryogenic equipment - Electric currents - Electric resistance measurement - Electric windings - Hall effect - Quantum electronics - Resistors - SQUIDs;
D O I
10.1049/ip-smt:20020758
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A cryogenic current comparator (CCC) bridge for quantum Hall resistance ratio measurement has been constructed. Compared to previous CCC systems at the National Physical Laboratory, UK, the new system differs in two aspects. Firstly, it uses a type-II CCC, i.e. the ratio windings are on the outside and the detection winding is on the inside. This has the advantage that the CCC can be made very compact and fits into a standard storage Dewar. Secondly, the bridge electronics uses a digital servo and the SQUID feedback loop is disabled during current reversals. The overall relative measurement uncertainty of the system is of the order of 10(-9).
引用
收藏
页码:302 / 304
页数:3
相关论文
共 50 条
  • [31] ISOLATED RAMPING CURRENT SOURCES FOR A CRYOGENIC CURRENT COMPARATOR BRIDGE
    ELMQUIST, RE
    DZIUBA, RF
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (10): : 2457 - 2460
  • [32] A CURRENT COMPARATOR BRIDGE FOR THE DIRECT MEASUREMENT OF 51.6 kΩ AGAINST THE QUANTISED HALL RESISTANCE
    Fletcher, N.
    Goebel, R.
    2010 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS CPEM, 2010, : 575 - 576
  • [33] Accurate determination of the balance point of a current comparator bridge for resistance standards measurements
    Ince, R
    Sakarya, H
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1999, 48 (06) : 1246 - 1253
  • [34] THE RATIO ERROR OF THE OVERLAPPED-TUBE CRYOGENIC CURRENT COMPARATOR
    SEPPA, H
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1990, 39 (05) : 689 - 697
  • [35] Dark current measurements on a superconducting cavity using a cryogenic current comparator
    Geithner, R.
    Neubert, R.
    Vodel, W.
    Seidel, P.
    Knaack, K.
    Vilcins, S.
    Wittenburg, K.
    Kugeler, O.
    Knobloch, J.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (01):
  • [36] A Resistance Bridge Based on a Cryogenic Current Comparator Achieving Sub-10-9 Measurement Uncertainties
    Poirier, Wilfrid
    Leprat, Dominique
    Schopfer, Felicien
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [37] Cryogenic current comparator for absolute measurements of the dark current of superconducting cavities for TESLA
    Vodel, W
    Neubert, R
    Nietzsche, S
    Knaack, K
    Wendt, M
    Wittenburg, K
    Peters, A
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2003, 13 (02) : 743 - 746
  • [38] AUTOMATION OF THE DIRECT-CURRENT COMPARATOR RESISTANCE BRIDGE
    AIDUN, R
    CATON, R
    ARAJS, S
    PRAMANA, 1984, 22 (06) : 567 - 572
  • [39] DIRECT-CURRENT COMPARATOR BRIDGE FOR RESISTANCE THERMOMETRY
    KUSTERS, NL
    MACMARTI.MP
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1970, IM19 (04) : 291 - &
  • [40] Cryogenic current comparator bridge supplying current up to 1 A and current dependence measurement of 1 Ω resistor
    Nakanishi, M
    Kinoshita, J
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2003, 42 (10): : 6641 - 6644