DC SUPERCONDUCTING QUANTUM INTERFERENCE DEVICE MAGNETOMETER FOR CRYOGENIC CURRENT COMPARATOR

被引:2
|
作者
NAKANISHI, M
机构
[1] Electrotechnical Laboratory, Tsukuba-shi, Ibaraki
关键词
SQUID; HIGH INPUT INDUCTANCE; CRYOGENIC CURRENT COMPARATOR; CURRENT AMPLIFIER; DESIGN AND FABRICATION;
D O I
10.1143/JJAP.33.5713
中图分类号
O59 [应用物理学];
学科分类号
摘要
A conventional de superconducting quantum interference device (de-SQUID) magnetometer was developed to improve current resolution of a cryogenic current comparator (CCC). Its resolution of magnetic flux in the frequency range from 1/100 to 1 Hz was 6.8 x 10(-20) Wb and was six orders of magnitude better that of a rf-SQUID magnetometer usually used for a CCC.
引用
收藏
页码:5713 / 5717
页数:5
相关论文
共 50 条
  • [1] RESISTANCE RATIO BRIDGE USING CRYOGENIC CURRENT COMPARATOR WITH DC-SUPERCONDUCTING QUANTUM INTERFERENCE DEVICE MAGNETOMETER
    NAKANISHI, M
    KINOSHITA, J
    ENDO, T
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1995, 34 (6A): : 3284 - 3289
  • [2] Calibration of a superconducting quantum interference device magnetometer
    Koyano, T
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2004, 43 (10): : 7322 - 7323
  • [3] THEORY FOR THE MULTILOOP DC SUPERCONDUCTING QUANTUM INTERFERENCE DEVICE MAGNETOMETER AND EXPERIMENTAL-VERIFICATION
    DRUNG, D
    KNAPPE, S
    KOCH, H
    [J]. JOURNAL OF APPLIED PHYSICS, 1995, 77 (08) : 4088 - 4098
  • [4] Observation of superconducting device using magnetic imaging system with a micro-DC superconducting quantum interference device magnetometer
    Morooka, T
    Nakayama, S
    Odawara, A
    Chinone, K
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 1999, 38 (2A): : L119 - L122
  • [5] Tracing the characteristics of a flux qubit with a hysteretic dc-superconducting quantum interference device comparator
    Castellano, MG
    Chiarello, F
    Leoni, R
    Simeone, D
    Torrioli, G
    Cosmelli, C
    Buttiglione, R
    Poletto, S
    Carelli, P
    [J]. JOURNAL OF APPLIED PHYSICS, 2003, 94 (12) : 7935 - 7937
  • [6] An absolute magnetometer based on dc Superconducting QUantum Interference Devices
    Carelli, P
    Castellano, MG
    Flacco, K
    Leoni, R
    Torrioli, G
    [J]. EUROPHYSICS LETTERS, 1997, 39 (05): : 569 - 574
  • [7] AN 8-T SUPERCONDUCTING QUANTUM INTERFERENCE DEVICE MAGNETOMETER
    GENNA, JC
    BISTON, S
    COTILLARD, JC
    LETHUILLIER, P
    FAURIN, C
    HOSTACHY, P
    ROCCAVALERO, R
    ROULLIER, J
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (07): : 1824 - 1827
  • [8] INSTABILITIES AND CHAOTIC SOLUTIONS OF THE CURRENT BIASED DC SUPERCONDUCTING QUANTUM INTERFERENCE DEVICE
    KETOJA, JA
    KURKIJARVI, J
    RITALA, RK
    [J]. PHYSICAL REVIEW B, 1984, 30 (07): : 3757 - 3764
  • [9] Radio frequency bias current scheme for dc superconducting quantum interference device
    Zhang, Y
    He, DF
    Wolters, N
    Otto, R
    Barthels, K
    Zeng, XH
    Yi, HR
    Krause, HJ
    Braginski, AI
    Faley, MI
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1999, 9 (02) : 3813 - 3816
  • [10] Measurements of biomagnetic fields using a high-resolution dc superconducting quantum interference device magnetometer
    Iramina, K
    Hong, B
    Uchida, S
    Goto, K
    Ueno, S
    Nakayama, S
    [J]. JOURNAL OF APPLIED PHYSICS, 1998, 83 (11) : 6465 - 6467