CFD TWO-SCALE MODEL OF A WET NATURAL DRAFT COOLING TOWER

被引:12
|
作者
Klimanek, Adam [1 ]
Bialecki, Ryszard A. [1 ]
Ostrowski, Ziemowit [1 ]
机构
[1] Silesian Tech Univ, Inst Thermal Technol, PL-44100 Gliwice, Poland
关键词
D O I
10.1080/10407780903582935
中图分类号
O414.1 [热力学];
学科分类号
摘要
A 2-D axisymmetric model of multiphase heat, mass, and momentum transfer phenomena in natural draft cooling tower is developed using a CFD code Fluent. The fill of the tower is modeled as a porous medium. The energy and mass sources in this zone are evaluated solving a separate 1-D model of mass and heat exchange. The spatial dependence of the sources is accounted for by dividing the fill into a set of vertical channels. The CFD solver produces boundary conditions for each channel, while the model of the channel exports the heat and mass sources to the CFD solver. To accelerate the calculations, an original technique known as the proper orthogonal decomposition (POD) is applied. This approach produces a reduced dimensionality model resulting in significant time economy and accuracy loss lower than 2%. The Euler-Euler multiphase model is used in the rain zone. The simulation results have been validated against experimental data coming from field measurements of a large industrial installation.
引用
收藏
页码:119 / 137
页数:19
相关论文
共 50 条
  • [21] Numerical Simulation of Flow Fields in a Natural Draft Wet-Cooling Tower
    Xiang-liang Yang
    Feng-zhong Sun
    Kai Wang
    Yue-tao Shi
    Nai-hua Wang
    Journal of Hydrodynamics, 2007, 19 : 762 - 768
  • [22] Influence factor analysis of inlet spray on a natural draft wet cooling tower
    Cheng, W.
    Hou, C.
    BULGARIAN CHEMICAL COMMUNICATIONS, 2016, 48 : 177 - 184
  • [23] NUMERICAL SIMULATION OF FLOW FIELDS IN A NATURAL DRAFT WET-COOLING TOWER
    YANG Xiang-liang Heze Power Plant
    JournalofHydrodynamics, 2007, (06) : 762 - 768
  • [24] Comparative study on the cooling characteristics of high level water collecting natural draft wet cooling tower and the usual cooling tower
    Zhao, Yuanbin
    Sun, Fengzhong
    Long, Guoqing
    Huang, Xiaofeng
    Huang, Wenqiang
    Lyv, Dongqiang
    ENERGY CONVERSION AND MANAGEMENT, 2016, 116 : 150 - 164
  • [25] A SIMPLIFIED MODEL FOR PREDICTING NATURAL DRAFT WET COOLING TOWER PERFORMANCE OF LARGE STEAM POWER PLANTS
    Wiesche, Stefan Aus Der
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, VOL 9, 2020,
  • [26] CFD MODELING ANALYSIS OF MECHANICAL DRAFT COOLING TOWER
    Lee, Si Y.
    Bollinger, James S.
    Garrett, Alfred J.
    Koffman, Larry D.
    HT2008: PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE - 2008, VOL 2, 2009, : 485 - 493
  • [27] Impact mechanism of the chip muffler on the cooling performance of super large-scale natural draft wet cooling tower under crosswind
    Zhang, Xiaoyu
    Sun, Fengzhong
    Chen, Xuehong
    Deng, Weipeng
    Chen, Kun
    APPLIED THERMAL ENGINEERING, 2022, 213
  • [28] Water Consumption Comparison Between a Natural Draft Wet Cooling Tower and a Natural Draft Hybrid Cooling TowerAn Annual Simulation for Luoyang Conditions
    Xia, Lin
    Li, Jishun
    Ma, Wei
    Gurgenci, Hal
    Guan, Zhiqiang
    Wang, Pei
    HEAT TRANSFER ENGINEERING, 2017, 38 (11-12) : 1034 - 1043
  • [29] Field test of the effect of crosswind on ventilation performance of a natural draft wet cooling tower
    Sun, F. (sfzh@sdu.edu.cn), 2012, Chinese Society for Electrical Engineering (32):
  • [30] Evaporative cooling of water in a natural draft cooling tower
    Fisenko, SP
    Petruchik, AI
    Solodukhin, AD
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2002, 45 (23) : 4683 - 4694