Field test of the effect of crosswind on ventilation performance of a natural draft wet cooling tower

被引:0
|
作者
机构
[1] Zhang, Lei
[2] Gao, Ming
[3] Chen, Youliang
[4] Shi, Yuetao
[5] Sun, Fengzhong
来源
Sun, F. (sfzh@sdu.edu.cn) | 2012年 / Chinese Society for Electrical Engineering卷 / 32期
关键词
Cooling - Drag coefficient - Air - Cooling towers - Testing - Ventilation - Deflection (structures) - Inlet flow;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [1] Field test study on thermal and ventilation performance for natural draft wet cooling tower after structural improvement
    Zhang, Zhengqing
    Gao, Ming
    Wang, Mingyong
    Guan, Hongjun
    Dang, Zhigang
    He, Suoying
    Sun, Fengzhong
    APPLIED THERMAL ENGINEERING, 2019, 155 : 305 - 312
  • [2] Field test on ventilation performance for high level water collecting wet cooling tower under crosswind conditions
    Zou, Jian
    He, Suoying
    Long, Guoqing
    Sun, Fengzhong
    Gao, Ming
    APPLIED THERMAL ENGINEERING, 2018, 133 : 439 - 445
  • [3] Effect of cooling water salinity on the cooling performance of natural draft wet cooling tower
    Wan, Dawei
    Gao, Shasha
    Liu, Minghua
    Li, Shuguo
    Zhao, Yuanbin
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 161
  • [4] Ventilation enhancement for a natural draft dry cooling tower in crosswind via windbox installation
    Wang, Weiliang
    Zhang, Hai
    Lyu, Junfu
    Liu, Qing
    Yue, Guangxi
    Ni, Weidou
    APPLIED THERMAL ENGINEERING, 2018, 137 : 93 - 100
  • [5] A performance enhancement of a natural draft dry cooling tower in crosswind via inlet flow field reconstruction
    Wang, Weiliang
    Lyu, Junfu
    Zhang, Hai
    Liu, Qing
    Yue, Guangxi
    Ni, Weidou
    ENERGY AND BUILDINGS, 2018, 164 : 121 - 130
  • [6] The influence and analysis of natural crosswind on cooling characteristics of the high level water collecting natural draft wet cooling tower
    Ma, Libin
    Ren, Jianxing
    2017 3RD INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND MATERIAL APPLICATION (ESMA2017), VOLS 1-4, 2018, 108
  • [7] Numerical analysis of crosswind effect on wet cooling tower aerodynamic field
    College of Energy Source and Power, Shandong University, Jinan 250061, China
    不详
    不详
    Hedongli Gongcheng, 2008, 6 (35-40): : 35 - 40
  • [8] Impact mechanism of the chip muffler on the cooling performance of super large-scale natural draft wet cooling tower under crosswind
    Zhang, Xiaoyu
    Sun, Fengzhong
    Chen, Xuehong
    Deng, Weipeng
    Chen, Kun
    APPLIED THERMAL ENGINEERING, 2022, 213
  • [9] SIMULTANEOUS EFFECTS OF WATER SPRAY AND CROSSWIND ON PERFORMANCE OF NATURAL DRAFT DRY COOLING TOWER
    Ahmadikia, Hossein
    Soleimani, Mohsen
    Gholami, Ehsan
    THERMAL SCIENCE, 2013, 17 (02): : 443 - 455
  • [10] Investigation of the crosswind-influenced thermal performance of a natural draft counterflow cooling tower
    Mondal, Pranab Kumar
    Mukherjee, Sanchayan
    Kundu, Balaram
    Wongwises, Somchai
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 85 : 1049 - 1057