Stability values of titanium dioxide-blasted dental implants in edentulous maxillas: a 3-year pilot study

被引:5
|
作者
Veltri, M. [1 ]
Ferrari, M. [2 ]
Balleri, P.
机构
[1] Univ Siena, Sch Dent Med, Policlin Le Scotte, Dept Oral Surg, I-53100 Siena, Italy
[2] Univ Siena, Dept Dent Mat & Fixed Prosthodont, I-53100 Siena, Italy
关键词
resonance frequency analysis; Astra Tech implants; RESONANCE FREQUENCY-ANALYSIS; AUTOGENOUS BONE; RECONSTRUCTION; PROSTHESES; PLACEMENT; IMMEDIATE; FAILURES; 5-YEAR;
D O I
10.1111/j.1365-2842.2009.02021.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
P>The purpose of this follow-up study was to measure the resonance frequency of Astra Tech TiO2 blasted implants at second surgery, at one and 3 years of loading. Secondly, it was investigated whether resonance frequency at second surgery could discriminate between successful implants and those that will fail over a 3-year period. Fifty titanium dioxide-blasted implants in eight consecutive patients with edentulous maxillas seeking fixed rehabilitations, were included in the study at abutment connection after 6 months of healing. Resonance frequency, clinical and radiographic records were obtained at abutment connection and after one and 3 years of loading. The cumulative survival rate after 3 years was 100%. The mean resonance frequencies were 65 +/- 4 center dot 8 implant stability quotient (ISQ) at second surgery (range 50-78 ISQ), 66 +/- 3 center dot 4 ISQ after 1 year of loading (range 53-76 ISQ) and 64 +/- 3 center dot 8 ISQ after 3 years of loading (range 53-77 ISQ). No significant differences resulted between these three time points. The marginal bone level decrease of 0 center dot 6 mm between the second surgery and the 3-year follow-up was observed. One limitation of the study is that no late failures were encountered in this relatively small sample. Consequently, it was not possible to establish a cut-off ISQ for implants that, after abutment connection, would maintain their stability over a 3-year period. Nevertheless, it might be concluded that following the first year of loading the range of 53-76 ISQ describes the stability of osseointegrated Astra Tech TiO2 blasted implants.
引用
收藏
页码:63 / 68
页数:6
相关论文
共 50 条
  • [41] Patient's opinion and treatment outcome of fixed rehabilitation on Branemark implants - A 3-year follow-up study in private dental practices
    deBruyn, H
    Collaert, B
    Linden, U
    Bjorn, AL
    CLINICAL ORAL IMPLANTS RESEARCH, 1997, 8 (04) : 265 - 271
  • [42] Stability of dental health behavior: a 3-year prospective cohort study of 15-, 16- and 18-year-old Norwegian adolescents
    Astrom, AN
    Jakobsen, R
    COMMUNITY DENTISTRY AND ORAL EPIDEMIOLOGY, 1998, 26 (02) : 129 - 138
  • [43] Prospective Pilot Study of Immediately Provisionalized Restorations of Trabecular Metal-Enhanced Titanium Dental Implants: A 5-Year Follow-Up Report
    van der Schoor, Peter
    Schlee, Markus
    Wen, Hai-Bo
    APPLIED SCIENCES-BASEL, 2022, 12 (03):
  • [44] 10-year survival rate and the incidence of peri-implant disease of 374 titanium dental implants with a SLA surface: a prospective cohort study in 177 fully and partially edentulous patients
    van Velzen, Frank J. J.
    Ofec, Ronen
    Schulten, Engelbert A. J. M.
    ten Bruggenkate, Christiaan M.
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (10) : 1121 - 1128
  • [45] Dental implants treatment outcomes in patient under active therapy with alendronate: 3-year follow-up results of a multicenter prospective observational study
    Tallarico, Marco
    Canullo, Luigi
    Xhanari, Erta
    Meloni, Silvio Mario
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (08) : 943 - 949
  • [46] Clinical and radiographic evaluation of narrow- vs. regular-diameter dental implants: a 3-year follow-up. A retrospective study
    Zweers, J.
    van Doornik, A.
    Hogendorf, E. A. H.
    Quirynen, M.
    Van der Weijden, G. A.
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (02) : 149 - 156
  • [47] Clinical Success of Dental Implants Placed in Posterior Mandible Augmented With Interpositional Block Graft: 3-Year Results From a Prospective Cohort Clinical Study
    Marconcini, Simone
    Covani, Ugo
    Giammarinaro, Enrica
    Velasco-Ortega, Eugenio
    De Santis, Daniele
    Alfonsi, Fortunato
    Barone, Antonio
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2019, 77 (02) : 289 - 298
  • [48] Evaluation of hard tissue 3-dimensional stability around single implants placed with guided bone regeneration in the anterior maxilla: A 3-year retrospective study
    Chen, Haida
    Gu, Tianyi
    Lai, Haiyan
    Gu, Xinhua
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (05): : 919 - 927
  • [49] Titanium-zirconium narrow-diameter versus titanium regular-diameter implants for anterior and premolar single crowns: 3-year results of a randomized controlled clinical study
    Ioannidis, Alexis
    Gallucci, German O.
    Jung, Ronald E.
    Borzangy, Sary
    Haemmerle, Christoph H. F.
    Benic, Goran I.
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2015, 42 (11) : 1060 - 1070
  • [50] Safety and effectiveness of early loaded maxillary titanium implants with a novel nanostrudured calcium-incorporated surface (Xpeed): 3-year results from a pilot multicenter randomised controlled trial
    Felice, Pietro
    Grusovin, Maria Gabriella
    Barausse, Carlo
    Grandi, Giovanni
    Esposito, Marco
    EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2015, 8 (03) : 245 - 254