Stability values of titanium dioxide-blasted dental implants in edentulous maxillas: a 3-year pilot study

被引:5
|
作者
Veltri, M. [1 ]
Ferrari, M. [2 ]
Balleri, P.
机构
[1] Univ Siena, Sch Dent Med, Policlin Le Scotte, Dept Oral Surg, I-53100 Siena, Italy
[2] Univ Siena, Dept Dent Mat & Fixed Prosthodont, I-53100 Siena, Italy
关键词
resonance frequency analysis; Astra Tech implants; RESONANCE FREQUENCY-ANALYSIS; AUTOGENOUS BONE; RECONSTRUCTION; PROSTHESES; PLACEMENT; IMMEDIATE; FAILURES; 5-YEAR;
D O I
10.1111/j.1365-2842.2009.02021.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
P>The purpose of this follow-up study was to measure the resonance frequency of Astra Tech TiO2 blasted implants at second surgery, at one and 3 years of loading. Secondly, it was investigated whether resonance frequency at second surgery could discriminate between successful implants and those that will fail over a 3-year period. Fifty titanium dioxide-blasted implants in eight consecutive patients with edentulous maxillas seeking fixed rehabilitations, were included in the study at abutment connection after 6 months of healing. Resonance frequency, clinical and radiographic records were obtained at abutment connection and after one and 3 years of loading. The cumulative survival rate after 3 years was 100%. The mean resonance frequencies were 65 +/- 4 center dot 8 implant stability quotient (ISQ) at second surgery (range 50-78 ISQ), 66 +/- 3 center dot 4 ISQ after 1 year of loading (range 53-76 ISQ) and 64 +/- 3 center dot 8 ISQ after 3 years of loading (range 53-77 ISQ). No significant differences resulted between these three time points. The marginal bone level decrease of 0 center dot 6 mm between the second surgery and the 3-year follow-up was observed. One limitation of the study is that no late failures were encountered in this relatively small sample. Consequently, it was not possible to establish a cut-off ISQ for implants that, after abutment connection, would maintain their stability over a 3-year period. Nevertheless, it might be concluded that following the first year of loading the range of 53-76 ISQ describes the stability of osseointegrated Astra Tech TiO2 blasted implants.
引用
收藏
页码:63 / 68
页数:6
相关论文
共 50 条
  • [21] Reconstruction of the atrophic edentulous maxilla with free iliac crest grafts and implants:: A 3-year report of a prospective clinical study
    Sjostrom, Mats
    Sennerby, Lars
    Nilson, Hans
    Lundgren, Stefan
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2007, 9 (01) : 46 - 59
  • [22] Three-year Radiologic Follow-up of Marginal Bone Loss Around Titanium Dioxide Grit-Blasted Dental Implants With and Without Fluoride Treatment
    Geckili, Onur
    Bilhan, Hakan
    Mumcu, Emre
    Bilgin, Tayfun
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (02) : 319 - 324
  • [23] Straight Versus Angulated Abutments on Tilted Implants in Immediate Fixed Rehabilitation of the Edentulous Mandible: A 3-Year Retrospective Comparative Study
    Sannino, Gianpaolo
    Barlattani, Alberto
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2016, 29 (03) : 219 - 226
  • [24] Immediate versus early non-occlusal loading of dental implants placed flapless in partially edentulous patients: A 3-year randomized clinical trial
    Merli, Mauro
    Moscatelli, Marco
    Mariotti, Giorgia
    Piemontese, Matteo
    Nieri, Michele
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2012, 39 (02) : 196 - 202
  • [25] RCT comparing implants with turned and anodically oxidized surfaces: A pilot study, a 3-year follow-up
    Nicu, Elena A.
    Van Assche, Nele
    Coucke, Wim
    Teughels, Wim
    Quirynen, Marc
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2012, 39 (12) : 1183 - 1190
  • [26] Quality of fixed restorative treatment on Branemark implants -: A 3-year follow-up study in private dental practices
    De Bruyn, H
    Lindén, U
    Collaert, B
    Björn, AL
    CLINICAL ORAL IMPLANTS RESEARCH, 2000, 11 (03) : 248 - 255
  • [27] Seven mm long dental implants in posterior jaws: 3-year report of an ongoing prospective single cohort study
    Malo, Paulo
    Nobre, Miguel de Araujo
    Lopes, Armando
    Goncgalves, Ines
    Nunes, Mariana
    EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2017, 10 (01) : 85 - 93
  • [28] Clinical Evaluation of Short (6 mm) and Longer Implants Placed Side by Side in Posterior Partially Edentulous Area: A 3-Year Observational Study
    Shimogishi, Masahiro
    Kawakami, Sawako
    Tachikawa, Noriko
    INTERNATIONAL JOURNAL OF DENTISTRY, 2023, 2023
  • [29] Values Stability and Change in Adulthood: A 3-Year Longitudinal Study of Rank-Order Stability and Mean-Level Differences
    Milfont, Taciano L.
    Milojev, Petar
    Sibley, Chris G.
    PERSONALITY AND SOCIAL PSYCHOLOGY BULLETIN, 2016, 42 (05) : 572 - 588
  • [30] Effect of Platelet-Rich Plasma on the Outcome of Early Loaded Dental Implants: A 3-Year Follow-up Study
    Ergun, Gulfem
    Egilmez, Ferhan
    Cekic-Nagas, Sit
    Karaca, Inci Rana
    Bozkaya, Suleyman
    JOURNAL OF ORAL IMPLANTOLOGY, 2013, 39 : 256 - 263