Stability values of titanium dioxide-blasted dental implants in edentulous maxillas: a 3-year pilot study

被引:5
|
作者
Veltri, M. [1 ]
Ferrari, M. [2 ]
Balleri, P.
机构
[1] Univ Siena, Sch Dent Med, Policlin Le Scotte, Dept Oral Surg, I-53100 Siena, Italy
[2] Univ Siena, Dept Dent Mat & Fixed Prosthodont, I-53100 Siena, Italy
关键词
resonance frequency analysis; Astra Tech implants; RESONANCE FREQUENCY-ANALYSIS; AUTOGENOUS BONE; RECONSTRUCTION; PROSTHESES; PLACEMENT; IMMEDIATE; FAILURES; 5-YEAR;
D O I
10.1111/j.1365-2842.2009.02021.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
P>The purpose of this follow-up study was to measure the resonance frequency of Astra Tech TiO2 blasted implants at second surgery, at one and 3 years of loading. Secondly, it was investigated whether resonance frequency at second surgery could discriminate between successful implants and those that will fail over a 3-year period. Fifty titanium dioxide-blasted implants in eight consecutive patients with edentulous maxillas seeking fixed rehabilitations, were included in the study at abutment connection after 6 months of healing. Resonance frequency, clinical and radiographic records were obtained at abutment connection and after one and 3 years of loading. The cumulative survival rate after 3 years was 100%. The mean resonance frequencies were 65 +/- 4 center dot 8 implant stability quotient (ISQ) at second surgery (range 50-78 ISQ), 66 +/- 3 center dot 4 ISQ after 1 year of loading (range 53-76 ISQ) and 64 +/- 3 center dot 8 ISQ after 3 years of loading (range 53-77 ISQ). No significant differences resulted between these three time points. The marginal bone level decrease of 0 center dot 6 mm between the second surgery and the 3-year follow-up was observed. One limitation of the study is that no late failures were encountered in this relatively small sample. Consequently, it was not possible to establish a cut-off ISQ for implants that, after abutment connection, would maintain their stability over a 3-year period. Nevertheless, it might be concluded that following the first year of loading the range of 53-76 ISQ describes the stability of osseointegrated Astra Tech TiO2 blasted implants.
引用
收藏
页码:63 / 68
页数:6
相关论文
共 50 条
  • [31] Simultaneous or staged installation with guided. bo-neaugmentation. of' transmucosal titanium implants -: A 3-year prospective cohort study
    Christensen, DK
    Karoussis, IK
    Joss, A
    Hämmerle, CH
    Lang, NP
    CLINICAL ORAL IMPLANTS RESEARCH, 2003, 14 (06) : 680 - 686
  • [32] Long-Term Outcomes of Dental Implants with a Titanium Plasma-Sprayed Surface: A 20-Year Prospective Case Series Study in Partially Edentulous Patients
    Chappuis, Vivianne
    Buser, Ramona
    Braegger, Urs
    Bornstein, Michael M.
    Salvi, Giovanni E.
    Buser, Daniel
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2013, 15 (06) : 780 - 790
  • [33] Clinical evaluation of single 4-mm implants in the posterior mandible: A 3-year follow-up pilot study
    Leighton, Yerko
    Carpio, Luis
    Weber, Benjamin
    Dias, Fernando Jose
    Borie, Eduardo
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (01): : 80 - 85
  • [34] 3-YEAR LONGITUDINAL-STUDY OF 60 CONSECUTIVELY PLACED ITI HOLLOW-CYLINDER AND HOLLOW-SCREW DENTAL IMPLANTS
    LISTGARTEN, MA
    JOURNAL OF DENTAL RESEARCH, 1995, 74 : 477 - 477
  • [35] Evaluation of the Peri-Implant Bone Level around Platform-Switched Dental Implants: A Retrospective 3-Year Radiographic Study
    Pan, Yu Hwa
    Lin, His Kuei
    Lin, Jerry C-Y
    Hsu, Yung-Szu
    Wu, Yi-Fan
    Salamanca, Eisner
    Chang, Wei-Jen
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2019, 16 (14)
  • [36] Dental implants placed in expanded narrow edentulous ridges with the Extension Crest® device -: A 1-3-year multicenter follow-up study
    Chiapasco, M
    Ferrini, F
    Casentini, P
    Accardi, S
    Zaniboni, M
    CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 (03) : 265 - 272
  • [37] Papilla-Crown Height Dimensions around Zirconium Dioxide Implants in the Esthetic Area: A 3-Year Follow-Up Study
    Kniha, Kim
    Schlegel, Karl Andreas
    Kniha, Heinz
    Modabber, Ali
    Neukam, Friedrich
    Kniha, Kristian
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (02): : E694 - E698
  • [38] Performance of zirconia ceramic cantilever fixed dental prostheses: 3-Year results from a prospective, randomized, controlled pilot study
    Zenthoefer, Andreas
    Ohlmann, Brigitte
    Rammelsberg, Peter
    Boemicke, Wolfgang
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (01): : 34 - 39
  • [39] Relationship Between Primary Stability and Crestal Bone Loss of Implants Placed with High Insertion Torque: A 3-Year Prospective Study
    De Santis, Daniele
    Cucchi, Alessandro
    Rigoni, Giovanni
    Longhi, Carlo
    Nocini, Pier Francesco
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (05) : 1126 - 1134B
  • [40] Effect of Opposite Tooth Condition on Marginal Bone Loss around Submerged Dental Implants: A Retrospective Study with a 3-Year Follow-Up
    Dorj, Odontuya
    Lin, Hsi-Kuei
    Salamanca, Eisner
    Pan, Yu-Hwa
    Wu, Yi-Fan
    Hsu, Yung-Szu
    Lin, Jerry C-Y
    Lin, Chin-Kai
    Chang, Wei-Jen
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (20)