Patient-specific region-of-interest fluoroscopy device for X-ray dose reduction

被引:6
|
作者
Xu, T [1 ]
Le, HQ [1 ]
Molloi, S [1 ]
机构
[1] Univ Calif Irvine, Dept Radiol Sci, Irvine, CA 92697 USA
关键词
fluoroscopy; technology; images; processing; phantoms; radiations; exposure to patients and personnel; radiography; test objects;
D O I
10.1148/radiol.2262011812
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A region-of-interest (ROI) fluoroscopy device that provides an automatically generated ROI filter with an arbitrary shape, as well as digitally compensated images, was built and evaluated. ROI filters were generated by using a deformable attenuation material. Images were compensated by using a compensation ratio and a running average interpolation method. image compensation parameters were predicted on the basis of the x-ray tube potential used. The image quality with and without an ROI filter was evaluated. This ROI fluoroscopic technique was shown to substantially reduce patient and operator radiation exposure without degrading image quality within the ROI. (C) RSNA, 2003.
引用
收藏
页码:585 / 592
页数:8
相关论文
共 50 条
  • [31] Low-Dose Real-Time Region-Of-Interest X-Ray Fluoroscopic Imaging with a GPU-Accelerated Spatially Different Bilateral Filtering
    Chung, H.
    Lee, J.
    Pua, R.
    Jung, W.
    Cho, S.
    MEDICAL PHYSICS, 2014, 41 (06) : 138 - 138
  • [32] NOISE REDUCTION IN LOW-DOSE X-RAY FLUOROSCOPY FOR IMAGE-GUIDED RADIATION THERAPY
    Jing Wang
    Lei Zhu
    Lei Xing
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (02): : 637 - 643
  • [33] A Patient-Specific Self-supervised Model for Automatic X-Ray/CT Registration
    Zhang, Baochang
    Faghihroohi, Shahrooz
    Azampour, Mohammad Farid
    Liu, Shuting
    Ghotbi, Reza
    Schunkert, Heribert
    Navab, Nassir
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION, MICCAI 2023, PT IX, 2023, 14228 : 515 - 524
  • [34] Patient-Specific Computational Models of Coronary Arteries Using Monoplane X-Ray Angiograms
    Zifan, Ali
    Liatsis, Panos
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2016, 2016
  • [35] INCOMPLETE DATA PROBLEMS IN X-RAY COMPUTERIZED-TOMOGRAPHY .2. TRUNCATED PROJECTIONS AND REGION-OF-INTEREST TOMOGRAPHY
    LOUIS, AK
    RIEDER, A
    NUMERISCHE MATHEMATIK, 1989, 56 (04) : 371 - 383
  • [36] Optimization-based region-of-interest reconstruction for X-ray computed tomography based on total variation and data derivative
    Cai, Ailong
    Li, Lei
    Wang, Linyuan
    Yan, Bin
    Zheng, Zhizhong
    Zhang, Hanming
    Hu, Guoen
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 48 : 91 - 102
  • [37] Local fiber orientation from X-ray region-of-interest computed tomography of large fiber reinforced composite components
    Baranowski, Thomas
    Dobrovolskij, Dascha
    Dremel, Kilian
    Hoelzing, Astrid
    Lohfink, Guenter
    Schladitz, Katja
    Zabler, Simon
    COMPOSITES SCIENCE AND TECHNOLOGY, 2019, 183
  • [38] Assessment of organ and effective dose when using region-of-interest attenuators in cone-beam CT and interventional fluoroscopy
    Xiong Z.
    Vijayan S.
    Rudin S.
    Bednarek D.R.
    Journal of Medical Imaging, 2017, 4 (03)
  • [39] Measurement of the dose deposition characteristics of x-ray fluoroscopy beams in water
    Fetterly, KA
    Gerbi, BJ
    Alaei, P
    Geise, RA
    MEDICAL PHYSICS, 2001, 28 (02) : 205 - 209
  • [40] CdZnTe detector arrays for low-dose x-ray fluoroscopy
    Heanue, JA
    Pearson, DA
    Melen, RE