Patient-specific region-of-interest fluoroscopy device for X-ray dose reduction

被引:6
|
作者
Xu, T [1 ]
Le, HQ [1 ]
Molloi, S [1 ]
机构
[1] Univ Calif Irvine, Dept Radiol Sci, Irvine, CA 92697 USA
关键词
fluoroscopy; technology; images; processing; phantoms; radiations; exposure to patients and personnel; radiography; test objects;
D O I
10.1148/radiol.2262011812
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A region-of-interest (ROI) fluoroscopy device that provides an automatically generated ROI filter with an arbitrary shape, as well as digitally compensated images, was built and evaluated. ROI filters were generated by using a deformable attenuation material. Images were compensated by using a compensation ratio and a running average interpolation method. image compensation parameters were predicted on the basis of the x-ray tube potential used. The image quality with and without an ROI filter was evaluated. This ROI fluoroscopic technique was shown to substantially reduce patient and operator radiation exposure without degrading image quality within the ROI. (C) RSNA, 2003.
引用
收藏
页码:585 / 592
页数:8
相关论文
共 50 条
  • [21] Region-of-Interest Tomography for Grating-Based X-Ray Differential Phase-Contrast Imaging
    Pfeiffer, F.
    David, C.
    Bunk, O.
    Donath, T.
    Bech, M.
    Le Duc, G.
    Bravin, A.
    Cloetens, P.
    PHYSICAL REVIEW LETTERS, 2008, 101 (16)
  • [22] A theoretical and experimental evaluation of the microangiographic fluoroscope: A high-resolution region-of-interest x-ray imager
    Jain, Amit
    Bednarek, D. R.
    Ionita, Ciprian
    Rudin, S.
    MEDICAL PHYSICS, 2011, 38 (07) : 4112 - 4126
  • [23] ROI-Finder: machine learning to guide region-of-interest scanning for X-ray fluorescence microscopy
    Chowdhury, M. A. Z.
    Ok, K.
    Luo, Y.
    Liu, Z.
    Chen, S.
    O'Halloran, T., V
    Kettimuthu, R.
    Tekawade, A.
    JOURNAL OF SYNCHROTRON RADIATION, 2022, 29 (06) : 1495 - 1503
  • [24] HOW SAFE IS X-RAY AND FLUOROSCOPY FOR THE PATIENT AND THE DOCTOR
    CLEIN, NW
    JOURNAL OF PEDIATRICS, 1954, 45 (03): : 310 - 315
  • [25] X-RAY DOSE REDUCTION IN EXAMINATION OF INFANTS HIP WITH IMAGE-INTENSIFIER-FLUOROSCOPY-SYSTEM
    DORN, U
    KRISTEN, H
    RESCH, P
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1978, 91 (02) : 101 - 105
  • [26] Reconstruction of patient-specific femurs using X-ray and sparse CT images
    Koh, Kyung
    Kim, Yoon Hyuk
    Kim, Kyungsoo
    Park, Won Man
    COMPUTERS IN BIOLOGY AND MEDICINE, 2011, 41 (07) : 421 - 426
  • [27] A Device Enhancing and Denoising Algorithm for X-ray Cardiac Fluoroscopy
    Bismuth, Vincent
    Vaillant, Regis
    19TH INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION, VOLS 1-6, 2008, : 1802 - 1805
  • [28] Comment on "Region-of-Interest Tomography for Grating-Based X-Ray Differential Phase-Contrast Imaging"
    Koehler, Thomas
    Noo, Frederic
    PHYSICAL REVIEW LETTERS, 2009, 102 (03)
  • [29] ROLE OF SPECTRAL DETERMINATION AND SHAPING IN REDUCTION OF PATIENT X-RAY DOSE
    WAGGENER, RG
    ROGERS, LF
    ZANCA, P
    PHYSICS IN MEDICINE AND BIOLOGY, 1972, 17 (01): : 121 - &
  • [30] "Focused" CT: A Reconstruction Algorithm Permitting Radiation Dose Reduction for Region-Of-Interest Viewing
    Olson, T.
    Leon, S.
    MEDICAL PHYSICS, 2021, 48 (06)