Establishing ionising radiation safety culture during interventional cardiovascular procedures

被引:3
|
作者
van der Merwe, Belinda [1 ]
机构
[1] Cent Univ Technol Free State, Fac Hlth & Environm Sci, Dept Clin Sci, Bloemfontein, South Africa
关键词
occupational exposure; radiation safety; interven-tional; cardiovascular; PROTECTION; TIME;
D O I
10.5830/CVJA-2021-030
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: The safety culture of an interventional labora-tory was investigated in terms of the application of the three cardinal principles of radiation protection, namely distance, time and shielding. Methods: The application of these principles was observed and recorded with a radiation safety-culture checklist that was compiled by consulting international recommendations. The checklist evaluated the optimal compliance, especially with reference to monitoring of staff exposure, distance from the X-ray source, fluoroscopy techniques pertaining to frame rate, protective devices and personal shielding. The effective radiation dose was measured to the eyes, thyroid, hands and feet of the cardiologist, nurse, floor nurse and radiographer by means of finger dosimeters that were readily available from the local radiation-protection dosimetry service. Results: The results, after observing 11 procedures, indicated the absence of table and ceiling-suspended shields, and the distance of the cardiologist's and scrub nurse's feet from the X-ray tube were between 16 and 68 cm, with a mean distance of 59.7 and 58.5 cm, respectively. Most staff (91%) wore the dosimeter inside the lead apron at the collar level without eye protection. The highest dosimeter values recorded were 0.73 mSv to the hand of the cardiologist, 0.45 mSv to the eye of the cardiologist, 0.65 mSv to the hand of the scrub nurse, 0.54 mSv to the eye of the scrub nurse and 0.52 mSv to the foot of the scrub nurse. The dosimeter value to the radiographer's thyroid was 0.42 mSv. Conclusions: The dosimeter readings confirmed the highest doses were to the scrub nurse and hand of the interventional-ist. The safety culture was non-compliant in terms of staff distance being too close to the X-ray tube, the absence of ceiling and table screens, the theatre door not always being completely closed, and for staff without lead eye glasses,
引用
收藏
页码:271 / 275
页数:5
相关论文
共 50 条
  • [21] Establishing diagnostic reference levels for interventional procedures in Kenya
    Korir, Geoffrey K.
    Wambani, Jeska S.
    Yuko-Jowi, Christine A.
    Korir, Ian K.
    Tries, Mark
    Kidali, Mike M.
    RADIOGRAPHY, 2014, 20 (02) : 148 - 152
  • [22] A safety net to prevent embolization during interventional procedures: Work in progress
    Kerr, A
    Marsan, B
    Lyon, R
    Hochsztein, J
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 9 (06) : 1020 - 1024
  • [23] Controlling radiation exposure during interventional procedures in childhood cancer patients
    Racadio, John M.
    PEDIATRIC RADIOLOGY, 2009, 39 : S71 - S73
  • [24] Controlling radiation exposure during interventional procedures in childhood cancer patients
    John M. Racadio
    Pediatric Radiology, 2009, 39 : 71 - 73
  • [25] Radiation Doses in Patient Eye Lenses during Interventional Neuroradiology Procedures
    Sanchez, R. M.
    Vano, E.
    Fernandez, J. M.
    Rosati, S.
    Lopez-Ibor, L.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (03) : 402 - 407
  • [26] Patient radiation exposure measurements during interventional procedures: A prospective study
    Efstathopoulos, Efstathios P.
    Brountzos, Elias N.
    Alexopoulou, Efthimia
    Argentos, Stylianos
    Kelekis, Dimitrios A.
    Raptou, Panagiota D.
    Kelekis, Nikolaos L.
    HEALTH PHYSICS, 2006, 91 (01): : 36 - 40
  • [27] Patient radiation exposure during diagnostic and therapeutic interventional neuroradiology procedures
    Alexander, M. D.
    Oliff, M. C.
    Olorunsola, O. G.
    Brus-Ramer, M.
    Nickoloff, E. L.
    Meyers, P. M.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2010, 2 (01) : 6 - 10
  • [28] RADIATION DOSES TO ANAESTHETISTS DURING PROSTATIC ARTERY EMBOLIZATION INTERVENTIONAL PROCEDURES
    Garzon, W. J.
    Khoury, H. J.
    RADIATION PROTECTION DOSIMETRY, 2019, 185 (02) : 196 - 200
  • [29] ASSESSMENT OF IONIZING RADIATION DOSES DELIVERED TO CARDIOLOGISTS DURING INTERVENTIONAL PROCEDURES
    Gedvilas, Marius
    Griciene, Birute
    Medvedevas, Nikolajus
    MEDICAL PHYSICS IN THE BALTIC STATES, 2011, : 124 - 126
  • [30] INTER-COMPARISON OF SAFETY CULTURE WITHIN SELECTED PRACTICES IN GHANA UTILISING IONISING RADIATION
    Faanu, A.
    Schandorf, C.
    Darko, E. O.
    Boadu, M.
    Emi-Reynolds, G.
    Awudu, A. R.
    Gyekye, P. K.
    Kpeglo, D. O.
    RADIATION PROTECTION DOSIMETRY, 2010, 142 (2-4) : 88 - 91