ASSESSMENT OF IONIZING RADIATION DOSES DELIVERED TO CARDIOLOGISTS DURING INTERVENTIONAL PROCEDURES

被引:0
|
作者
Gedvilas, Marius [1 ]
Griciene, Birute
Medvedevas, Nikolajus [1 ]
机构
[1] Kaunas Univ Technol, Kaunas, Lithuania
关键词
interventional; cardiology; coronary angiography; percutaneous coronary intervention; skin dose equivalent; thermoluminescence dosimeter; personal dose equivalent;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Interventional radiology provides a great number of vascular and extravascular information and therefore are commonly used in medical practice. The complexity of interventional procedures causes relative high doses to interventional cardiologists due to near vicinity of radiation source during procedures. In this paper results of measurements by thermoluminescence dosimeters of skin doses at different body height levels and doses to eye lenses accessible by interventional cardiologists are presented and discussed.
引用
收藏
页码:124 / 126
页数:3
相关论文
共 50 条
  • [1] Assessment of radiation doses to cardiologists during interventional examinations
    Bor, D.
    Olgar, T.
    Onal, E.
    Caglan, A.
    Toklu, T.
    MEDICAL PHYSICS, 2009, 36 (08) : 3730 - 3736
  • [2] Estimation of cardiologists radiation doses received during interventional examinations
    Bor, D.
    Onal, E.
    Olgar, T.
    Caglan, A.
    Toklu, T.
    MEDICAL PHYSICS, 2006, 33 (06) : 2211 - 2212
  • [3] Occupational radiation doses during interventional procedures
    Nuraeni, N.
    Hiswara, E.
    Kartikasari, D.
    Waris, A.
    Haryanto, F.
    13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
  • [4] Assessment of occupational radiation doses to eye lens during interventional radiology procedures
    Ali, Amir
    Al-Nuaimi, Meshari
    Khan, Banaras
    Burki, Shamsullah
    Nishtar, Tahira
    Yaseen, Muhammad
    Shah, Syed Sher Azam
    Irfan, Muhammad
    RADIATION PHYSICS AND CHEMISTRY, 2024, 225
  • [5] Eye lens radiation exposure to interventional cardiologists: a retrospective assessment of cumulative doses
    Jacob, Sophie
    Donadille, Laurent
    Maccia, Carlo
    Bar, Olivier
    Boveda, Serge
    Laurier, Dominique
    Bernier, Marie-Odile
    RADIATION PROTECTION DOSIMETRY, 2013, 153 (03) : 282 - 293
  • [6] THE EFFECT OF LEAD FREE CAP ON THE DOSES OF IONIZING RADIATION TO THE HEAD OF INTERVENTIONAL CARDIOLOGISTS WORKING IN HAEMODYNAMIC ROOM
    Grabowicz, Wlodzimierz
    Masiarek, Konrad
    Gornik, Tomasz
    Grycewicz, Tomasz
    Brodecki, Marcin
    Dabin, Jeremie
    Huet, Christelle
    Vanhavere, Filip
    Domienik-Andrzejewska, Joanna K.
    INTERNATIONAL JOURNAL OF OCCUPATIONAL MEDICINE AND ENVIRONMENTAL HEALTH, 2022, 35 (05) : 549 - 560
  • [7] OCCUPATIONAL EXPOSURE TO IONIZING RADIATION AND LENS OPACITY IN INTERVENTIONAL CARDIOLOGISTS
    Domienik-Andrzejewska, Joanna
    Kaluzny, Pawel
    Piernik, Gabriela
    Jurewicz, Joanna
    INTERNATIONAL JOURNAL OF OCCUPATIONAL MEDICINE AND ENVIRONMENTAL HEALTH, 2019, 32 (05) : 663 - 675
  • [8] Radiation exposure to cardiologists performing interventional cardiology procedures
    Delichas, M
    Psarrakos, K
    Molyvda-Athanassopoulou, E
    Giannoglou, G
    Sioundas, A
    Hatziioannou, K
    Papanastassiou, E
    EUROPEAN JOURNAL OF RADIOLOGY, 2003, 48 (03) : 268 - 273
  • [9] Analysis of ionizing radiation doses received by patients during electrocardiological procedures
    Biegala, Michal
    Zabczynski, Lukasz
    Staniszewska, Maria Anna
    IRISH JOURNAL OF MEDICAL SCIENCE, 2024, 193 (05) : 2217 - 2221
  • [10] Radiation Doses in Patient Eye Lenses during Interventional Neuroradiology Procedures
    Sanchez, R. M.
    Vano, E.
    Fernandez, J. M.
    Rosati, S.
    Lopez-Ibor, L.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (03) : 402 - 407