Establishing ionising radiation safety culture during interventional cardiovascular procedures

被引:3
|
作者
van der Merwe, Belinda [1 ]
机构
[1] Cent Univ Technol Free State, Fac Hlth & Environm Sci, Dept Clin Sci, Bloemfontein, South Africa
关键词
occupational exposure; radiation safety; interven-tional; cardiovascular; PROTECTION; TIME;
D O I
10.5830/CVJA-2021-030
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: The safety culture of an interventional labora-tory was investigated in terms of the application of the three cardinal principles of radiation protection, namely distance, time and shielding. Methods: The application of these principles was observed and recorded with a radiation safety-culture checklist that was compiled by consulting international recommendations. The checklist evaluated the optimal compliance, especially with reference to monitoring of staff exposure, distance from the X-ray source, fluoroscopy techniques pertaining to frame rate, protective devices and personal shielding. The effective radiation dose was measured to the eyes, thyroid, hands and feet of the cardiologist, nurse, floor nurse and radiographer by means of finger dosimeters that were readily available from the local radiation-protection dosimetry service. Results: The results, after observing 11 procedures, indicated the absence of table and ceiling-suspended shields, and the distance of the cardiologist's and scrub nurse's feet from the X-ray tube were between 16 and 68 cm, with a mean distance of 59.7 and 58.5 cm, respectively. Most staff (91%) wore the dosimeter inside the lead apron at the collar level without eye protection. The highest dosimeter values recorded were 0.73 mSv to the hand of the cardiologist, 0.45 mSv to the eye of the cardiologist, 0.65 mSv to the hand of the scrub nurse, 0.54 mSv to the eye of the scrub nurse and 0.52 mSv to the foot of the scrub nurse. The dosimeter value to the radiographer's thyroid was 0.42 mSv. Conclusions: The dosimeter readings confirmed the highest doses were to the scrub nurse and hand of the interventional-ist. The safety culture was non-compliant in terms of staff distance being too close to the X-ray tube, the absence of ceiling and table screens, the theatre door not always being completely closed, and for staff without lead eye glasses,
引用
收藏
页码:271 / 275
页数:5
相关论文
共 50 条
  • [31] Interventional magnetic resonance imaging: An alternative to image guidance with ionising radiation
    Bock, M
    Umathum, R
    Zuehlsdorff, S
    Volz, S
    Fink, C
    Hallscheidt, P
    Zimmermann, H
    Nitz, W
    Semmler, W
    RADIATION PROTECTION DOSIMETRY, 2005, 117 (1-3) : 74 - 78
  • [32] Radiofrequency safety for interventional MRI procedures
    Atalar, E
    ACADEMIC RADIOLOGY, 2005, 12 (09) : 1149 - 1157
  • [33] Fluoroscopy and safety of spinal interventional procedures
    Munir, MA
    Rastogi, R
    Nedeljkovic, S
    ANESTHESIA AND ANALGESIA, 2006, 102 (05): : 1586 - 1586
  • [34] Measurement of occupational doses of ionising radiation to the lens of the eyes of interventional radiologists
    Higgins, Anthony
    JOURNAL OF RADIOLOGICAL PROTECTION, 2016, 36 (01) : 74 - 92
  • [35] Patient Safety in Interventional Pain Procedures
    Thampi, Samuel P.
    Rekhala, Vishal
    Vontobel, Travis
    Nukula, Vamsi
    PHYSICAL MEDICINE AND REHABILITATION CLINICS OF NORTH AMERICA, 2012, 23 (02) : 423 - +
  • [36] Radiation dose in interventional fluoroscopic procedures
    Geise, RA
    O'Dea, TJ
    APPLIED RADIATION AND ISOTOPES, 1999, 50 (01) : 173 - 184
  • [37] Radiation Exposure in Pediatric Interventional Procedures
    Ploussi, Agapi
    Brountzos, Elias
    Rammos, Spyridon
    Apostolopoulou, Sotiria
    Efstathopoulos, Efstathios P.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2021, 44 (06) : 857 - 865
  • [38] Radiation Exposure in Pediatric Interventional Procedures
    Agapi Ploussi
    Elias Brountzos
    Spyridon Rammos
    Sotiria Apostolopoulou
    Efstathios P. Efstathopoulos
    CardioVascular and Interventional Radiology, 2021, 44 : 857 - 865
  • [39] Radiation Protection Optimisation in Interventional Procedures
    Samet, Nina
    Staniszewska, Maria Anna
    RADIATION PROTECTION IN MEDICAL PHYSICS, 2009, : 177 - +
  • [40] Innovations in Radiation Safety During Cardiovascular Catheterization
    Brilakis, Emmanouil S.
    CIRCULATION, 2018, 137 (13) : 1317 - 1319