PET iterative reconstruction incorporating an efficient positron range correction method

被引:36
|
作者
Bertolli, Ottavia [1 ,2 ,3 ]
Eleftheriou, Afroditi [1 ,4 ]
Cecchetti, Matteo [2 ,3 ]
Camarlinghi, Niccol [2 ,3 ]
Belcari, Nicola [2 ,3 ]
Tsoumpas, Charalampos [1 ]
机构
[1] Univ Leeds, Div Biomed Imaging, Leeds LS2 9JT, W Yorkshire, England
[2] Univ Pisa, Pisa, Italy
[3] Ist Nazl Fis Nucl, Pisa, Italy
[4] Univ Athens, Dept Phys, Athens 11528, Greece
来源
关键词
Positron range; Iterative reconstruction; PET; PET/MR; STIR; SIMULATION;
D O I
10.1016/j.ejmp.2015.11.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Positron range is one of the main physical effects limiting the spatial resolution of positron emission tomography (PET) images. If positrons travel inside a magnetic field, for instance inside a nuclear magnetic resonance (MR) tomograph, the mean range will be smaller but still significant. In this investigation we examined a method to correct for the positron range effect in iterative image reconstruction by including tissue-specific kernels in the forward projection operation. The correction method was implemented within STIR library (Software for Tomographic Image Reconstruction). In order to obtain the positron annihilation distribution of various radioactive isotopes in water and lung tissue, simulations were performed with the Monte Carlo package GATE [Jan et al. 2004 [1]] simulating different magnetic field intensities (0 T, 3 T, 9.5 T and 11 T) along the axial scanner direction. The positron range kernels were obtained for Ga-68 in water and lung tissue for 0 T and 3 T magnetic field voxellizing the annihilation coordinates into a three-dimensional matrix. The proposed method was evaluated using simulations of material-variant and material-invariant positron range corrections for the HYPERImage preclinical PET-MR scanner. The use of the correction resulted in sharper active region boundary definition, albeit with noise enhancement, and in the recovery of the true activity mean value of the hot regions. Moreover, in the case where a magnetic field is present, the correction accounts for the non-isotropy of the positron range effect, resulting in the recovery of resolution along the axial plane. (C) 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:323 / 330
页数:8
相关论文
共 50 条
  • [31] Spatially Variant Positron Range Modeling Derived from CT for PET Image Reconstruction
    Alessio, Adam
    MacDonald, Lawrence
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 2912 - 2915
  • [32] Fast Positron Range Calculation in Heterogeneous Media for 3D PET Reconstruction
    Szirmay-Kalos, Laszlo
    Magdics, Milan
    Toth, Balazs
    Csebfalvi, Balazs
    Umenhoffer, Tamas
    Lantos, Judit
    Patay, Gergely
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2150 - 2155
  • [33] Positron Range Correction for 82Rb myocardial PET: Validation in a healthy cohort
    Lassen, M.
    Kertesz, H.
    Rausch, I.
    Kjaer, A.
    Panin, V.
    Bharkhada, D.
    DeKemp, R.
    Beyer, T.
    Hasbak, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S200 - S201
  • [34] Experimental validation of gallium production and isotope-dependent positron range correction in PET
    Fraile, L. M.
    Herraiz, J. L.
    Udias, J. M.
    Cal-Gonzalez, J.
    Corzo, P. M. G.
    Espana, S.
    Herranz, E.
    Perez-Liva, M.
    Picado, E.
    Vicente, E.
    Munoz-Martin, A.
    Vaquero, J. J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 814 : 110 - 116
  • [35] Positron-Range Correction for an On-Chip PET Scanner using Deep Learning
    Clement, C.
    Birindelli, G.
    Pagano, F.
    Pizzichemi, M.
    Julio, M. Kruithof-De
    Ziegler, S.
    Rominger, A.
    Auffray, E.
    Shi, K.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S162 - S162
  • [36] A new iterative reconstruction technique for attenuation correction in high-resolution positron emission tomography
    Knesaurek, K
    Machac, J
    Vallabhajosula, S
    Buchsbaum, MS
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1996, 23 (06): : 656 - 661
  • [37] Iterative reconstruction for attenuation correction in positron emission tomography: Maximum likelihood for transmission and blank scan
    Glatting, G
    Wuchenauer, M
    Reske, SN
    MEDICAL PHYSICS, 1999, 26 (09) : 1838 - 1842
  • [38] The influence of filtered back-projection and iterative reconstruction on partial volume correction in PET
    Kops, ER
    Krause, BJ
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2005, 44 (03): : 99 - 106
  • [39] Effects of attenuation correction and reconstruction method on PET activation studies
    Mesina, CT
    Boellaard, R
    van den Heuvel, OA
    Veltman, DJ
    Jongbloed, G
    van der Vaart, AW
    Lammertsma, AA
    NEUROIMAGE, 2003, 20 (02) : 898 - 908
  • [40] Improved attenuation correction method for SPECT by iterative filtered backprojection reconstruction
    Chuang, K.
    Lue, K.
    Lin, H.
    Wang, H.
    Ni, Y.
    Jan, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S366 - S366