PET iterative reconstruction incorporating an efficient positron range correction method

被引:36
|
作者
Bertolli, Ottavia [1 ,2 ,3 ]
Eleftheriou, Afroditi [1 ,4 ]
Cecchetti, Matteo [2 ,3 ]
Camarlinghi, Niccol [2 ,3 ]
Belcari, Nicola [2 ,3 ]
Tsoumpas, Charalampos [1 ]
机构
[1] Univ Leeds, Div Biomed Imaging, Leeds LS2 9JT, W Yorkshire, England
[2] Univ Pisa, Pisa, Italy
[3] Ist Nazl Fis Nucl, Pisa, Italy
[4] Univ Athens, Dept Phys, Athens 11528, Greece
来源
关键词
Positron range; Iterative reconstruction; PET; PET/MR; STIR; SIMULATION;
D O I
10.1016/j.ejmp.2015.11.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Positron range is one of the main physical effects limiting the spatial resolution of positron emission tomography (PET) images. If positrons travel inside a magnetic field, for instance inside a nuclear magnetic resonance (MR) tomograph, the mean range will be smaller but still significant. In this investigation we examined a method to correct for the positron range effect in iterative image reconstruction by including tissue-specific kernels in the forward projection operation. The correction method was implemented within STIR library (Software for Tomographic Image Reconstruction). In order to obtain the positron annihilation distribution of various radioactive isotopes in water and lung tissue, simulations were performed with the Monte Carlo package GATE [Jan et al. 2004 [1]] simulating different magnetic field intensities (0 T, 3 T, 9.5 T and 11 T) along the axial scanner direction. The positron range kernels were obtained for Ga-68 in water and lung tissue for 0 T and 3 T magnetic field voxellizing the annihilation coordinates into a three-dimensional matrix. The proposed method was evaluated using simulations of material-variant and material-invariant positron range corrections for the HYPERImage preclinical PET-MR scanner. The use of the correction resulted in sharper active region boundary definition, albeit with noise enhancement, and in the recovery of the true activity mean value of the hot regions. Moreover, in the case where a magnetic field is present, the correction accounts for the non-isotropy of the positron range effect, resulting in the recovery of resolution along the axial plane. (C) 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:323 / 330
页数:8
相关论文
共 50 条
  • [21] Iterative reconstruction in PET routine
    Schmidlin, P
    Bellemann, ME
    Doll, J
    Brix, G
    Lorenz, WJ
    RADIOACTIVE ISOTOPES IN CLINICAL MEDICINE AND RESEARCH, 1997, : 219 - 223
  • [22] A residual correction method for iterative reconstruction with inaccurate system model
    Fu, Lin
    Qi, Jinyi
    2008 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1-4, 2008, : 1311 - 1314
  • [23] Iterative reconstruction incorporating background correction improves quantification of [18F]-NaF PET/CT images of patients with abdominal aortic aneurysm
    Mercy I. Akerele
    Nicolas A. Karakatsanis
    Rachael O. Forsythe
    Marc R. Dweck
    Maaz Syed
    Robert G. Aykroyd
    Steven Sourbron
    David E. Newby
    Charalampos Tsoumpas
    Journal of Nuclear Cardiology, 2021, 28 : 1875 - 1886
  • [24] Iterative reconstruction incorporating background correction improves quantification of [18F]-NaF PET/CT images of patients with abdominal aortic aneurysm
    Akerele, Mercy, I
    Karakatsanis, Nicolas A.
    Forsythe, Rachael O.
    Dweck, Marc R.
    Syed, Maaz
    Aykroyd, Robert G.
    Sourbron, Steven
    Newby, David E.
    Tsoumpas, Charalampos
    JOURNAL OF NUCLEAR CARDIOLOGY, 2021, 28 (05) : 1875 - 1886
  • [25] Incorporating HYPR de-noising within iterative PET reconstruction (HYPR-OSEM)
    Cheng, Ju-Chieh
    Matthews, Julian
    Sossi, Vesna
    Anton-Rodriguez, Jose
    Salomon, Andre
    Boellaard, Ronald
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (16): : 6666 - 6687
  • [26] Incorporating HYPR de-noising within iterative PET reconstruction (HYPR-OSEM)
    Cheng, Ju-Chieh
    Salomon, Andre
    Boellaard, Ronald
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [27] 3-D ITERATIVE RECONSTRUCTION METHOD FOR STATIONARY PLANAR POSITRON CAMERAS
    LIM, CB
    CHENG, A
    BOYD, DP
    HATTNER, RS
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1978, 25 (01) : 196 - 201
  • [28] FAST ITERATIVE METHOD FOR 3-D POSITRON IMAGE-RECONSTRUCTION
    LIM, CB
    CHENG, A
    BOYD, D
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1977, 26 : 154 - 155
  • [29] Iterative reconstruction method based on median root prior in quantification with PET
    Katoh, C
    Alenius, S
    Ruotsalainen, U
    POSITRON EMISSION TOMOGRAPHY IN THE MILLENNIUM, 2000, 1197 : 265 - 270
  • [30] Evaluation of MAP image reconstruction with positron range modeling for 3D PET
    Bai, Bing
    Laforest, Richard
    Smith, Anne M.
    Leahy, Richard M.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2686 - 2689