Refractive outcomes of intraoperative wavefront aberrometry versus optical biometry alone for intraocular lens power calculation

被引:24
|
作者
Zhang, Zina [1 ]
Thomas, Logan William [1 ]
Leu, Szu-Yen [1 ]
Carter, Steven [1 ]
Garg, Sumit [1 ]
机构
[1] Univ Calif Irvine, Gavin Herbert Eye Inst, Dept Ophthalmol, 850 Hlth Sci Rd, Irvine, CA 92617 USA
关键词
Intraocular lens master; intraoperative wavefront aberrometry; optiwave refractive analysis; EYES;
D O I
10.4103/ijo.IJO_163_17
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the outcomes of intraoperative wavefront aberrometry versus optical biometry alone for intraocular lens (IOL) power calculation in eyes undergoing cataract surgery with monofocal IOL implantation. Methods: Preoperative data were obtained with the IOLMaster. Intraoperative aphakic measurements and IOL power calculations were obtained in some patients with the optiwave refractive analysis (ORA) system. Analysis was performed to determine the accuracy of monofocal IOL power prediction and postoperative manifest refraction at 1 month of the ORA versus IOLMaster. Results: Two hundred and ninety-five eyes reviewed, 61 had only preoperative IOLMaster measurements and 234 had both IOLMaster and ORA measurements. Of these 234 eyes, 6 were excluded, 107 had the same recommended IOL power by ORA and IOLMaster. Sixty-four percent of these eyes were within +/- 0.5D. 95 eyes had IOL power implantation based on ORA instead of IOLMaster. Seventy percent of these eyes were within +/- 0.5D of target refraction. 26 eyes had IOL power chosen based on IOLMaster predictions instead of ORA. Sixty-five percent were within +/- 0.5D. In the group with IOLMaster without ORA measurements, 80% of eyes were within +/- 0.5D of target refraction. The absolute error was statistically smaller in those eyes where the ORA and IOLMaster recommended the same IOL power based on preoperative target refraction compared to instances in which IOL selection was based on ORA or IOLMaster alone. Neither prediction errors were statistically different between the ORA and IOLMaster alone. Conclusion: Intraoperative wavefront aberrometry with the ORA system provides postoperative refractive results comparable to conventional biometry with the IOLMaster for monofocal IOL selection.
引用
收藏
页码:813 / 817
页数:5
相关论文
共 50 条
  • [41] Comparison of optical low-coherence reflectometry and applanation ultrasound biometry on intraocular lens power calculation
    Roncevic, Mirjana Bjelos
    Busic, Mladen
    Cima, Ivan
    Elabjer, Biljana Kuzmanovic
    Bosnar, Damir
    Miletic, Daliborka
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 249 (01) : 69 - 75
  • [42] Comparison of optical low-coherence reflectometry and applanation ultrasound biometry on intraocular lens power calculation
    Mirjana Bjeloš Rončević
    Mladen Bušić
    Ivan Čima
    Biljana Kuzmanović Elabjer
    Damir Bosnar
    Daliborka Miletić
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2011, 249 : 69 - 75
  • [43] Challenges in pediatric cataract surgery: comparison of intraocular lens power calculation formulas using optical biometry
    İbrahim Edhem Yılmaz
    Sabit Kimyon
    Alper Mete
    International Ophthalmology, 2022, 42 : 3071 - 3077
  • [44] Intraoperative aphakic refraction as an adjunct for intraocular lens power calculation in post-corneal refractive surgery
    Umesh, Y.
    Bhat, Shruti
    Balasubramaniam, Anand
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2021, 69 (10) : 2888 - +
  • [45] Intraoperative aberrometry compared to preoperative Barrett True-K formula for intraocular lens power selection in eyes with prior refractive surgery
    Gasparian, Suzie A.
    Nassiri, Saman
    You, Hyelin
    Vercio, Abby
    Hwang, Frank S.
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [46] Optical biometry intraocular lens power calculation using different formulas in patients with different axial lengths
    Wang, Jia-Kang
    Chang, Shu-Wen
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2013, 6 (02) : 150 - 154
  • [47] Biommetry and intraocular lens power calculation results with a new optical biometry device: Comparison with the gold standard
    Kaswin, Godefroy
    Rousseau, Antoine
    Mgarrech, Mohamed
    Barreau, Emmanuel
    Labetoulle, Marc
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (04): : 593 - 600
  • [48] Challenges in pediatric cataract surgery: comparison of intraocular lens power calculation formulas using optical biometry
    Yilmaz, Ibrahim Edhem
    Kimyon, Sabit
    Mete, Alper
    INTERNATIONAL OPHTHALMOLOGY, 2022, 42 (10) : 3071 - 3077
  • [49] Optical biometry intraocular lens power calculation using different formulas in patients with different axial lengths
    Jia-Kang Wang
    Shu-Wen Chang
    International Journal of Ophthalmology, 2013, (02) : 150 - 154
  • [50] Clinical outcomes of a diffractive trifocal intraocular lens with femtosecond laser, digital tracking, and intraoperative aberrometry
    Blaylock, John F.
    Hall, Brad
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2022, 57 (05): : 291 - 296