Refractive outcomes of intraoperative wavefront aberrometry versus optical biometry alone for intraocular lens power calculation

被引:24
|
作者
Zhang, Zina [1 ]
Thomas, Logan William [1 ]
Leu, Szu-Yen [1 ]
Carter, Steven [1 ]
Garg, Sumit [1 ]
机构
[1] Univ Calif Irvine, Gavin Herbert Eye Inst, Dept Ophthalmol, 850 Hlth Sci Rd, Irvine, CA 92617 USA
关键词
Intraocular lens master; intraoperative wavefront aberrometry; optiwave refractive analysis; EYES;
D O I
10.4103/ijo.IJO_163_17
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the outcomes of intraoperative wavefront aberrometry versus optical biometry alone for intraocular lens (IOL) power calculation in eyes undergoing cataract surgery with monofocal IOL implantation. Methods: Preoperative data were obtained with the IOLMaster. Intraoperative aphakic measurements and IOL power calculations were obtained in some patients with the optiwave refractive analysis (ORA) system. Analysis was performed to determine the accuracy of monofocal IOL power prediction and postoperative manifest refraction at 1 month of the ORA versus IOLMaster. Results: Two hundred and ninety-five eyes reviewed, 61 had only preoperative IOLMaster measurements and 234 had both IOLMaster and ORA measurements. Of these 234 eyes, 6 were excluded, 107 had the same recommended IOL power by ORA and IOLMaster. Sixty-four percent of these eyes were within +/- 0.5D. 95 eyes had IOL power implantation based on ORA instead of IOLMaster. Seventy percent of these eyes were within +/- 0.5D of target refraction. 26 eyes had IOL power chosen based on IOLMaster predictions instead of ORA. Sixty-five percent were within +/- 0.5D. In the group with IOLMaster without ORA measurements, 80% of eyes were within +/- 0.5D of target refraction. The absolute error was statistically smaller in those eyes where the ORA and IOLMaster recommended the same IOL power based on preoperative target refraction compared to instances in which IOL selection was based on ORA or IOLMaster alone. Neither prediction errors were statistically different between the ORA and IOLMaster alone. Conclusion: Intraoperative wavefront aberrometry with the ORA system provides postoperative refractive results comparable to conventional biometry with the IOLMaster for monofocal IOL selection.
引用
收藏
页码:813 / 817
页数:5
相关论文
共 50 条
  • [31] Intraocular lens power calculation by measuring axial length with partial optical coherence and ultrasonic biometry
    Fontes, Beatriz Machado
    Fontes, Bruno Machado
    Castro, Elaine
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2011, 74 (03) : 166 - 170
  • [32] Accuracy of optical biometry combined with Placido disc corneal topography for intraocular lens power calculation
    Savini, Giacomo
    Hoffer, Kenneth J.
    Barboni, Piero
    Balducci, Nicole
    Schiano-Lomoriello, Domenico
    Ducoli, Pietro
    PLOS ONE, 2017, 12 (02):
  • [33] Intraocular lens power calculation after refractive surgery
    Argento, C
    Cosentino, MJ
    Badoza, D
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (07): : 1346 - 1351
  • [34] Modern preoperative intraocular lens calculation is better than intraoperative aberrometry for normal eyes Reply
    Cionni, Robert J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (02): : 254 - 254
  • [35] Intraocular lens power calculation using intraoperative retinoscopy
    Happe, W
    Wiechens, B
    Haigis, W
    Behrendt, S
    Duncker, G
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1997, 210 (04) : 207 - 212
  • [36] Comparison of refractive outcomes for different intraocular lens formulae using ultrasound biometry
    Patel, Darshak S.
    Ilari, Luca
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [37] Intraocular lens power calculation for humanitarian missions based on partial biometry
    Schmitz, Joseph W.
    Davis, Kimberly D.
    IVcClatchey, Scott K.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (07): : 1187 - 1191
  • [38] Update Biometrie und KunstlinsenberechnungUpdate on biometry and intraocular lens power calculation
    Nino Hirnschall
    Oliver Findl
    Spektrum der Augenheilkunde, 2020, 34 : 137 - 143
  • [39] Comparison of Intraocular Lens Power Estimation by Optical Biometry and Ultrasound Biometry in Cataract Surgery
    Mohanty, Gayatree
    Rajguru, Himansu
    Agarwal, Khushi
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2022, 16 (06) : NC15 - NC18
  • [40] Intraoperative aberrometry compared to preoperative Barrett True-K formula for intraocular lens power selection in eyes with prior refractive surgery
    Suzie A. Gasparian
    Saman Nassiri
    Hyelin You
    Abby Vercio
    Frank S. Hwang
    Scientific Reports, 12