Intraoperative aberrometry compared to preoperative Barrett True-K formula for intraocular lens power selection in eyes with prior refractive surgery

被引:15
|
作者
Gasparian, Suzie A. [1 ]
Nassiri, Saman [1 ]
You, Hyelin [1 ]
Vercio, Abby [1 ]
Hwang, Frank S. [1 ]
机构
[1] Loma Linda Univ, Eye Inst, 11370 Anderson St,Suite 1800, Loma Linda, CA 92354 USA
关键词
IN-SITU KERATOMILEUSIS; CALCULATING IOL POWER; PHOTOREFRACTIVE KERATECTOMY; HAIGIS-L; ACCURACY; BIOMETRY;
D O I
10.1038/s41598-022-11462-8
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
To compare the predictive refractive accuracy of intraoperative aberrometry (ORA) to the preoperative Barrett True-K formula in the calculation of intraocular lens (IOL) power in eyes with prior refractive surgery undergoing cataract surgery at the Loma Linda University Eye Institute, Loma Linda, California, USA. We conducted a retrospective chart review of patients with a history of post-myopic or hyperopic LASIK/PRK who underwent uncomplicated cataract surgery between October 2016 and March 2020. Pre-operative measurements were performed utilizing the Barrett True-K formula. Intraoperative aberrometry (ORA) was used for aphakic refraction and IOL power calculation during surgery. Predictive refractive accuracy of the two methods was compared based on the difference between achieved and intended target spherical equivalent. A total of 97 eyes (69 patients) were included in the study. Of these, 81 eyes (83.5%) had previous myopic LASIK/PRK and 16 eyes (16.5%) had previous hyperopic LASIK/PRK. Median (MedAE)/mean (MAE) absolute prediction errors for preoperative as compared to intraoperative methods were 0.49 D/0.58 D compared to 0.42 D/0.51 D, respectively (P = 0.001/0.002). Over all, ORA led to a statistically significant lower median and mean absolute error compared to the Barrett True-K formula in post-refractive eyes. Percentage of eyes within +/- 1.00 D of intended target refraction as predicted by the preoperative versus the intraoperative method was 82.3% and 89.6%, respectively (P = 0.04). Although ORA led to a statistically significant lower median absolute error compared to the Barrett True-K formula, the two methods are clinically comparable in predictive refractive accuracy in patients with prior refractive surgery.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Intraoperative aberrometry compared to preoperative Barrett True-K formula for intraocular lens power selection in eyes with prior refractive surgery
    Suzie A. Gasparian
    Saman Nassiri
    Hyelin You
    Abby Vercio
    Frank S. Hwang
    Scientific Reports, 12
  • [2] Refractive Accuracy of Barrett True-K vs Intraoperative Aberrometry for IOL Power Calculation in Post-Corneal Refractive Surgery Eyes
    Gouvea, Larissa
    Sioufi, Kareem
    Brown, Colin E.
    Waring, George
    Chamon, Wallace
    Rocha, Karolinne Maia
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 4305 - 4315
  • [3] Comparison of intraocular lens power prediction by American Society of Cataract and Refractive Surgery formulas and Barrett True-K TK in eyes with prior laser refractive surgery
    Shetty, Naren
    Sathe, Priyanka
    Aishwarya
    Francis, Mathew
    Shetty, Rohit
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2024, 72 (08) : 1210 - 1213
  • [4] Stability of the Barrett True-K formula for intraocular lens power calculation after SMILE in Chinese myopic eyes
    Wei Zhu
    Feng-Ju Zhang
    Yu Li
    Yan-Zheng Song
    International Journal of Ophthalmology, 2020, 13 (04) : 560 - 566
  • [5] Stability of the Barrett True-K formula for intraocular lens power calculation after SMILE in Chinese myopic eyes
    Zhu, Wei
    Zhang, Feng-Ju
    Li, Yu
    Song, Yan-Zheng
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2020, 13 (04) : 560 - +
  • [6] Comparison of Preoperative Intraocular Lens Power Selection Methods to Intraoperative Aberrometry in Short Eyes
    Sudhakar, Shruti
    Hill, Darren
    Hill, Christopher
    Scott, Ingrid U.
    Ernst, Brett
    Pantanelli, Seth
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [7] Intraoperative aberrometry versus preoperative biometry for intraocular lens power selection in short eyes
    Sudhakar, Shruti
    Hill, Darren C.
    King, Tonya S.
    Scott, Ingrid U.
    Mishra, Gautam
    Ernst, Brett B.
    Pantanelli, Seth M.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (06): : 719 - 724
  • [8] Comparison of Refractive Prediction for Intraoperative Aberrometry and Barrett True K No History Formula in Cataract Surgery Patients with Prior Radial Keratotomy
    Dawson, Valerie Jeanne
    Patnaik, Jennifer L.
    Miller, Claire
    Lynch, Anne M.
    Christopher, Karen L.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [9] Comparison of refractive prediction for intraoperative aberrometry and Barrett True K no history formula in cataract surgery patients with prior radial keratotomy
    Dawson, Valerie J.
    Patnaik, Jennifer L.
    Ifantides, Cristos
    Miller, D. Claire
    Lynch, Anne M.
    Christopher, Karen L.
    ACTA OPHTHALMOLOGICA, 2021, 99 (06) : E844 - E851
  • [10] Comparison of Preoperative Intraocular Lens Power Selection Methods to Intraoperative Aberrometry in Eyes with Axial Myopia
    Hill, Christopher Scott
    Hill, Darren
    Sudhakar, Shruti
    Scott, Ingrid U.
    Ernst, Brett
    Pantanelli, Seth
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)