Intraoperative aberrometry compared to preoperative Barrett True-K formula for intraocular lens power selection in eyes with prior refractive surgery

被引:15
|
作者
Gasparian, Suzie A. [1 ]
Nassiri, Saman [1 ]
You, Hyelin [1 ]
Vercio, Abby [1 ]
Hwang, Frank S. [1 ]
机构
[1] Loma Linda Univ, Eye Inst, 11370 Anderson St,Suite 1800, Loma Linda, CA 92354 USA
关键词
IN-SITU KERATOMILEUSIS; CALCULATING IOL POWER; PHOTOREFRACTIVE KERATECTOMY; HAIGIS-L; ACCURACY; BIOMETRY;
D O I
10.1038/s41598-022-11462-8
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
To compare the predictive refractive accuracy of intraoperative aberrometry (ORA) to the preoperative Barrett True-K formula in the calculation of intraocular lens (IOL) power in eyes with prior refractive surgery undergoing cataract surgery at the Loma Linda University Eye Institute, Loma Linda, California, USA. We conducted a retrospective chart review of patients with a history of post-myopic or hyperopic LASIK/PRK who underwent uncomplicated cataract surgery between October 2016 and March 2020. Pre-operative measurements were performed utilizing the Barrett True-K formula. Intraoperative aberrometry (ORA) was used for aphakic refraction and IOL power calculation during surgery. Predictive refractive accuracy of the two methods was compared based on the difference between achieved and intended target spherical equivalent. A total of 97 eyes (69 patients) were included in the study. Of these, 81 eyes (83.5%) had previous myopic LASIK/PRK and 16 eyes (16.5%) had previous hyperopic LASIK/PRK. Median (MedAE)/mean (MAE) absolute prediction errors for preoperative as compared to intraoperative methods were 0.49 D/0.58 D compared to 0.42 D/0.51 D, respectively (P = 0.001/0.002). Over all, ORA led to a statistically significant lower median and mean absolute error compared to the Barrett True-K formula in post-refractive eyes. Percentage of eyes within +/- 1.00 D of intended target refraction as predicted by the preoperative versus the intraoperative method was 82.3% and 89.6%, respectively (P = 0.04). Although ORA led to a statistically significant lower median absolute error compared to the Barrett True-K formula, the two methods are clinically comparable in predictive refractive accuracy in patients with prior refractive surgery.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Intraoperative aberrometry versus preoperative biometry for intraocular lens power selection in patients with axial hyperopia
    Bansal, Muskaan
    Thakur, Anchal
    Gupta, Gaurav
    Jurangal, Ajay
    Khanna, Rahul
    Malhotra, Chintan
    Gupta, Amit
    Jain, Arun Kumar
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2022, 70 (12) : 4295 - 4299
  • [22] Intraoperative Aberrometry versus Preoperative Biometry for Intraocular Lens Power Calculations
    Pantanelli, Seth M.
    Hatch, Kathryn
    Lin, Charles C.
    Steigleman, W. Allan
    Al-Mohtaseb, Zaina
    Rose-Nussbaumer, Jennifer R.
    Santhiago, Marcony R.
    Keenan, Tiarnan D. L.
    Kim, Stephen J.
    Jacobs, Deborah S.
    Schallhorn, Julie M.
    Daly, Meghan
    OPHTHALMOLOGY, 2025, 132 (02) : 238 - 252
  • [23] Modern preoperative intraocular lens calculation is better than intraoperative aberrometry for normal eyes
    Runde, Matt R.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (02): : 253 - 254
  • [24] Intraoperative aberrometry vs modern preoperative formulas in predicting intraocular lens power
    Raufi, Nikolas
    James, Charlene
    Kuo, Anthony
    Vann, Robin
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (06): : 857 - 861
  • [25] Accuracy of Intraoperative Aberrometry, Barrett True-K With and Without Posterior Cornea Measurements, Shammas-PL, and Haigis-L Formulas After Myopic Refractive Surgery
    Christopher, Karen L.
    Patnaik, Jennifer L.
    Miller, D. Claire
    Lynch, Anne M.
    Taravella, Michael J.
    Davidson, Richard S.
    JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (01) : 60 - 68
  • [26] The Use of Intraoperative Aberrometry in Normal Eyes: An Analysis of Intraocular Lens Selection in Scenarios of Disagreement
    Greenwood, Michael D.
    Hutchison, Jake W.
    Gorham, Richard A.
    Kramer, Brent A.
    JOURNAL OF REFRACTIVE SURGERY, 2022, 38 (05) : 304 - +
  • [27] Refractive outcomes using "Barrett True K Formula" for intraocular lens calculation in patients with radiated keratotomy
    Sanchez, Alejandra
    Zuniga, Karla
    Escalona Brito, Ana
    Chavez-Mondragon, Eduardo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [28] Modern preoperative intraocular lens calculation is better than intraoperative aberrometry for normal eyes Reply
    Cionni, Robert J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (02): : 254 - 254
  • [29] Results of the Barrett True-K formula for IOL power calculation based on Scheimpflug camera measurements in eyes with previous myopic excimer laser surgery
    Savini, Giacomo
    Hoffer, Kenneth J.
    Barrett, Graham D.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (07): : 1016 - 1019
  • [30] Intraoperative Refractive Biometry for Predicting Intraocular Lens Power Calculation after Prior Myopic Refractive Surgery
    Ianchulev, Tsontcho
    Hoffer, Kenneth J.
    Yoo, Sonia H.
    Chang, David F.
    Breen, Michael
    Padrick, Thomas
    Tran, Dan B.
    OPHTHALMOLOGY, 2014, 121 (01) : 56 - 60