Performance Analysis on the Optimum Control of a Calorimeter with a Heat Recovery Unit for a Heat Pump

被引:0
|
作者
Amoabeng, Kofi Owura [1 ]
Choi, Jong Min [2 ]
机构
[1] Hanbat Natl Univ, Mech Engn Grad Sch, Daejeon 34158, South Korea
[2] Hanbat Natl Univ, Mech Engn Dept, Daejeon 34158, South Korea
关键词
heat pump; calorimeter; test standard; control methods; heat exchanger; heat recovery; ENERGY EFFICIENCY; SYSTEM; TEMPERATURE; PRESSURE;
D O I
10.3390/en11092210
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Heat pumps are used in many applications, both in households and industries, for space air conditioning and hot water provision. The calorimeter is the equipment used in testing the heat pump system to obtain performance data. In the conventional testing mode and under standard conditions, the calorimeter utilizes a lot of energy through refrigeration and heating systems. In this study, a newly developed calorimeter with a heat recovery unit was used to test the performance of a water-to-water heat pump system. The aim was to minimize the rate of energy used in the conventional calorimeter. Two heat recovery control methods were adopted. In the control (1), the heat recovery unit was used to control the inlet water temperature setpoint for the heat pump indoor heat exchanger, whereas in control (2), the heat recovery unit was used to control the inlet water temperature setpoint for the heat pump outdoor heat exchanger. Tests were executed by varying the operating mode and test conditions. For the heating operating mode, the inlet water setpoint temperatures for the indoor and outdoor heat pump heat exchangers were 40 degrees C and 5 degrees C, respectively, whereas for the cooling mode, the inlet water setpoint temperatures for the outdoor and indoor heat pump heat exchangers were 25 degrees C and 12 degrees C, respectively. The analyses of the experimental results revealed that the energy saving of the calorimeter with heat recovery was about 71% in cooling mode and 73% in heating mode compared to the conventional calorimeter. Also, the energy consumption of the proposed calorimeter was analyzed based on the control methods. In heating mode, the calorimeter performance was enhanced when the control (2) strategy was used because the energy saving was about 8 to 13% compared to control (1). However, in the cooling mode test, it was the control (1) method that resulted in energy savings of about 6.4 to 21% compared to the control (2) method.
引用
收藏
页数:20
相关论文
共 50 条
  • [11] Experimental study on energy saving between heat pump unit of heat recovery fresh air and heat pipe heat pump low temperature heat recovery unit in the cold and severe cold regions
    Li, Yang
    Liang, Xiu Juan
    [J]. ENERGY ENGINEERING AND ENVIRONMENT ENGINEERING, 2014, 535 : 37 - +
  • [12] Study on the condensing heat recovery optimum model of the ground source heat pump system
    Zhou, E. Z.
    Fan, B.
    Dong, H.
    [J]. CRYOGENICS AND REFRIGERATION, PROCEEDINGS, 2008, : 445 - 449
  • [13] Exploring heating performance of gas engine heat pump with heat recovery
    Fu-jiang Dong
    Feng-guo Liu
    Xian-ting Li
    Xue-yi You
    Dong-fang Zhao
    [J]. Journal of Central South University, 2016, 23 : 1931 - 1936
  • [14] Exploring heating performance of gas engine heat pump with heat recovery
    Dong Fu-jiang
    Liu Feng-guo
    Li Xian-ting
    You Xue-yi
    Zhao Dong-fang
    [J]. JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2016, 23 (08) : 1931 - 1936
  • [15] Exploring heating performance of gas engine heat pump with heat recovery
    董付江
    刘凤国
    李先庭
    尤学一
    赵冬芳
    [J]. Journal of Central South University, 2016, 23 (08) : 1931 - 1936
  • [16] Performance of a novel mechanical ventilation heat recovery heat pump system
    Riffat, SB
    Gillott, MC
    [J]. APPLIED THERMAL ENGINEERING, 2002, 22 (07) : 839 - 845
  • [17] HEAT RECOVERY WITH CHEMICAL HEAT PUMP
    Czapnik, Marzena
    Tylman, Michal
    Jaskulski, Maciej
    Wawrzyniak, Pawel
    [J]. CHEMICAL AND PROCESS ENGINEERING-INZYNIERIA CHEMICZNA I PROCESOWA, 2019, 40 (03): : 273 - 279
  • [18] Evaluation of the coefficient of performance of an air source heat pump unit and an air to water heat pump
    Tangwe, S.
    Kusakana, K.
    [J]. JOURNAL OF ENERGY IN SOUTHERN AFRICA, 2021, 32 (01) : 27 - 40
  • [19] Thermodynamic performance analysis of air-to-air hybrid heat recovery unit driven by pump combined with booster
    Zhou, Feng
    Li, Dongzhe
    Chen, Rong
    Ma, Guoyuan
    [J]. JOURNAL OF BUILDING ENGINEERING, 2023, 77
  • [20] Annual energy performance of a thermoelectric heat pump combined with a heat recovery unit to HVAC one passive house dwelling
    Diaz de Garayo, S.
    Martinez, A.
    Astrain, D.
    [J]. APPLIED THERMAL ENGINEERING, 2022, 204