Performance Analysis on the Optimum Control of a Calorimeter with a Heat Recovery Unit for a Heat Pump

被引:0
|
作者
Amoabeng, Kofi Owura [1 ]
Choi, Jong Min [2 ]
机构
[1] Hanbat Natl Univ, Mech Engn Grad Sch, Daejeon 34158, South Korea
[2] Hanbat Natl Univ, Mech Engn Dept, Daejeon 34158, South Korea
关键词
heat pump; calorimeter; test standard; control methods; heat exchanger; heat recovery; ENERGY EFFICIENCY; SYSTEM; TEMPERATURE; PRESSURE;
D O I
10.3390/en11092210
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Heat pumps are used in many applications, both in households and industries, for space air conditioning and hot water provision. The calorimeter is the equipment used in testing the heat pump system to obtain performance data. In the conventional testing mode and under standard conditions, the calorimeter utilizes a lot of energy through refrigeration and heating systems. In this study, a newly developed calorimeter with a heat recovery unit was used to test the performance of a water-to-water heat pump system. The aim was to minimize the rate of energy used in the conventional calorimeter. Two heat recovery control methods were adopted. In the control (1), the heat recovery unit was used to control the inlet water temperature setpoint for the heat pump indoor heat exchanger, whereas in control (2), the heat recovery unit was used to control the inlet water temperature setpoint for the heat pump outdoor heat exchanger. Tests were executed by varying the operating mode and test conditions. For the heating operating mode, the inlet water setpoint temperatures for the indoor and outdoor heat pump heat exchangers were 40 degrees C and 5 degrees C, respectively, whereas for the cooling mode, the inlet water setpoint temperatures for the outdoor and indoor heat pump heat exchangers were 25 degrees C and 12 degrees C, respectively. The analyses of the experimental results revealed that the energy saving of the calorimeter with heat recovery was about 71% in cooling mode and 73% in heating mode compared to the conventional calorimeter. Also, the energy consumption of the proposed calorimeter was analyzed based on the control methods. In heating mode, the calorimeter performance was enhanced when the control (2) strategy was used because the energy saving was about 8 to 13% compared to control (1). However, in the cooling mode test, it was the control (1) method that resulted in energy savings of about 6.4 to 21% compared to the control (2) method.
引用
收藏
页数:20
相关论文
共 50 条
  • [21] Heat exchangers and the performance of heat pumps - Analysis of a heat pump database
    Kim, D. S.
    Moretti, I.
    Huber, H.
    Monsberger, M.
    [J]. APPLIED THERMAL ENGINEERING, 2011, 31 (05) : 911 - 920
  • [22] Optimum performance of a generalized irreversible carnot heat pump with a generalized heat transfer law
    Zhu, XQ
    Chen, LG
    Sun, FR
    Wu, C
    [J]. PHYSICA SCRIPTA, 2001, 64 (06) : 584 - 587
  • [23] On the optimum heat exchanger sizing for heat recovery
    Söylemez, MS
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2000, 41 (13) : 1419 - 1427
  • [24] Theoretical formulation and performance analysis of a novel hydride heat Pump(HHP) integrated heat recovery system
    Yang, Fusheng
    Wu, Zhen
    Liu, Shengzhe
    Zhang, Yang
    Wang, Geoff
    Zhang, Zaoxiao
    Wang, Yuqi
    [J]. ENERGY, 2018, 163 : 208 - 220
  • [25] Performance analysis of air-water dual source heat pump water heater with heat recovery
    CHEN ZeShaoTAO WenQuanZHU YanWen HU Peng Department of Thermal Science Energy EngineeringUniversity of Science and Technology of ChinaHefei China XiAn JiaoTong UniversityXian China HuaiAn HengXin CorporationHuaian China
    [J]. Science China(Technological Sciences)., 2012, 55 (08) - 2156
  • [26] Performance analysis of air-water dual source heat pump water heater with heat recovery
    CHEN ZeShao1
    2 Xi’An JiaoTong University
    3 Huai’An HengXin Corporation
    [J]. Science China Technological Sciences, 2012, (08) : 2148 - 2156
  • [27] Performance Analysis of Two Systems Combining Heat Pump and Water Vapor Compression for Waste Heat Recovery
    Zhang, Chunwei
    Chai, Dongdong
    Pan, Xi
    Xie, Junlong
    Chen, Jianye
    [J]. APPLIED SCIENCES-BASEL, 2022, 12 (24):
  • [28] Performance analysis of air-water dual source heat pump water heater with heat recovery
    Chen ZeShao
    Tao WenQuan
    Zhu YanWen
    Hu Peng
    [J]. SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2012, 55 (08) : 2148 - 2156
  • [29] Performance analysis of a heat pump dryer with separate heat recovery using an energy, exergy, and economic methodology
    Jin, Jianlong
    Geng, Xudong
    Huang, Qunxing
    Yuan, Ya
    Dong, Jian
    Lin, Chengqian
    Li, Bo
    Yang, Luwei
    [J]. DRYING TECHNOLOGY, 2023, 41 (09) : 1411 - 1425
  • [30] Performance analysis of air-water dual source heat pump water heater with heat recovery
    ZeShao Chen
    WenQuan Tao
    YanWen Zhu
    Peng Hu
    [J]. Science China Technological Sciences, 2012, 55 : 2148 - 2156