Stopped-flow system with ozonizer for the estimation of low biochemical oxygen demand in environmental samples

被引:12
|
作者
Chee, Gab-Joo
Nomura, Yoko
Ikebukuro, Kazunori
Karube, Isao
机构
[1] Japan Agcy Marine Earth Sci & Technol, Extremobiosphere Res Ctr, Yokosuka, Kanagawa 2370061, Japan
[2] Tokyo Technol Univ, Sch Bion, Hachioji, Tokyo 1928580, Japan
[3] Tokyo Univ Agr & Technol, Fac Engn, Dept Biotechnol & Life Sci, Koganei, Tokyo 1848588, Japan
来源
BIOSENSORS & BIOELECTRONICS | 2007年 / 22卷 / 12期
关键词
ozonation; BOD sensor; biosensor; biofilm; artificial wastewater; pseudomonas putida;
D O I
10.1016/j.bios.2007.01.014
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The stopped-flow system with an ozonizer was developed to estimate low biochemical oxygen demand (1301)) in rivers. Rivers contain many biopersistent organic compounds such as humic acid, lignin, and gum arabic. Free radicals generated by self-decomposition of ozone were used as powerful oxidants to split organic compounds. Ozonysis of the samples was carried out by 42.4 g N-1 M-3 ozone for 3 min at pH 7.0. Artificial wastewater (AWW) solutions were employed as standard solutions for the calibrations of the BOD sensor. At a BOD of 1 mg l(-1), the sensor response after ozonation was 1.6-fold higher than that before ozonation. The response time of the BOD sensor was only 5 min, being independent of the concentrations, and the lower detection limit was 0.5 mg 1(-1) BOD. The degradations of lignin and tannic acid by ozonation were 54.1 and 42.3%, respectively. In the biosensor responses by ozonation, lignin, gum arabic, and surfactant increased by double or more compared with previous responses. BOD in rivers was estimated using the stopped-flow system. Environmental samples pretreated with ozone gave high responses to the biosensor that were similar to those of the conventional BOD5 method. Accordingly, a good correlation between the sensor and the conventional BOD5 was obtained (r = 0.989). The system has to evolve the highly sensitive BOD determination. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:3092 / 3098
页数:7
相关论文
共 50 条
  • [31] AN EASILY CONSTRUCTED AND INEXPENSIVE STOPPED-FLOW SYSTEM FOR OBSERVING RAPID REACTIONS
    GRAY, ET
    WORKMAN, HJ
    JOURNAL OF CHEMICAL EDUCATION, 1980, 57 (10) : 752 - 755
  • [32] Biosensors for rapid estimation of biochemical oxygen demand
    Ye, YC
    Wang, JL
    Pu, LF
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (03) : 405 - 410
  • [33] A MODULAR FLUOROMETRIC STOPPED-FLOW SYSTEM FOR USE IN CLINICAL-CHEMISTRY
    GUTIERREZ, MC
    GOMEZHENS, A
    PEREZBENITO, D
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1987, 328 (1-2): : 120 - 124
  • [34] Zearalenone determination in corn silage samples using an immunosensor in a continuous-flow/stopped-flow systems
    Panini, Nancy V.
    Bertolino, Franco A.
    Salinas, Eloy
    Messina, German A.
    Raba, Julio
    BIOCHEMICAL ENGINEERING JOURNAL, 2010, 51 (1-2) : 7 - 13
  • [35] STOPPED-FLOW APPARATUS WITH TEMPERATURE CONTROL, FIBER OPTICS, AND CHEMICALLY INERT FLOW SYSTEM
    CALDIN, EF
    CROOKS, JE
    QUEEN, A
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1973, 6 (09): : 930 - 932
  • [36] APPLICATION OF DIFFERENTIAL-PULSE ANODIC-STRIPPING VOLTAMMETRY WITH A STOPPED-FLOW SYSTEM FOR THE SIMULTANEOUS DETERMINATION OF PB, CU, SB, AND BI IN ENVIRONMENTAL-SAMPLES
    WANG, FQ
    LI, SY
    LIU, SD
    ZHANG, YN
    LIU, ZY
    ANALYTICAL LETTERS, 1994, 27 (09) : 1779 - 1787
  • [37] A COMBINED NUCLEAR-MAGNETIC-RESONANCE AND ABSORBENCY STOPPED-FLOW APPARATUS FOR BIOCHEMICAL-STUDIES
    MCGEE, WA
    PARKHURST, LJ
    ANALYTICAL BIOCHEMISTRY, 1990, 189 (02) : 267 - 273
  • [38] EVALUATION OF A COMPUTER-CONTROLLED STOPPED-FLOW SYSTEM FOR FUNDAMENTAL KINETIC STUDIES
    MIELING, GE
    PARDUE, HL
    ANALYTICAL CHEMISTRY, 1978, 50 (09) : 1333 - 1337
  • [39] MICROCOMPUTER-AUTOMATED ONLINE REAGENT DILUTION SYSTEM FOR STOPPED-FLOW INSTRUMENTATION
    STIEG, S
    NIEMAN, TA
    ANALYTICAL CHEMISTRY, 1980, 52 (06) : 796 - 800
  • [40] Mechanism of a Disassembly-Driven Sensing System Studied by Stopped-Flow Kinetics
    Gallo, Cara
    Thomas, Suma S.
    Selinger, Allison J.
    Hof, Fraser
    Bohne, Cornelia
    JOURNAL OF ORGANIC CHEMISTRY, 2021, 86 (15): : 10782 - 10787