Stopped-flow system with ozonizer for the estimation of low biochemical oxygen demand in environmental samples

被引:12
|
作者
Chee, Gab-Joo
Nomura, Yoko
Ikebukuro, Kazunori
Karube, Isao
机构
[1] Japan Agcy Marine Earth Sci & Technol, Extremobiosphere Res Ctr, Yokosuka, Kanagawa 2370061, Japan
[2] Tokyo Technol Univ, Sch Bion, Hachioji, Tokyo 1928580, Japan
[3] Tokyo Univ Agr & Technol, Fac Engn, Dept Biotechnol & Life Sci, Koganei, Tokyo 1848588, Japan
来源
BIOSENSORS & BIOELECTRONICS | 2007年 / 22卷 / 12期
关键词
ozonation; BOD sensor; biosensor; biofilm; artificial wastewater; pseudomonas putida;
D O I
10.1016/j.bios.2007.01.014
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The stopped-flow system with an ozonizer was developed to estimate low biochemical oxygen demand (1301)) in rivers. Rivers contain many biopersistent organic compounds such as humic acid, lignin, and gum arabic. Free radicals generated by self-decomposition of ozone were used as powerful oxidants to split organic compounds. Ozonysis of the samples was carried out by 42.4 g N-1 M-3 ozone for 3 min at pH 7.0. Artificial wastewater (AWW) solutions were employed as standard solutions for the calibrations of the BOD sensor. At a BOD of 1 mg l(-1), the sensor response after ozonation was 1.6-fold higher than that before ozonation. The response time of the BOD sensor was only 5 min, being independent of the concentrations, and the lower detection limit was 0.5 mg 1(-1) BOD. The degradations of lignin and tannic acid by ozonation were 54.1 and 42.3%, respectively. In the biosensor responses by ozonation, lignin, gum arabic, and surfactant increased by double or more compared with previous responses. BOD in rivers was estimated using the stopped-flow system. Environmental samples pretreated with ozone gave high responses to the biosensor that were similar to those of the conventional BOD5 method. Accordingly, a good correlation between the sensor and the conventional BOD5 was obtained (r = 0.989). The system has to evolve the highly sensitive BOD determination. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:3092 / 3098
页数:7
相关论文
共 50 条
  • [41] RAPID SCANNING STOPPED-FLOW SYSTEM FOR TRANSIENT STATE ENZYME-KINETICS
    SUELTER, CH
    COOLEN, RB
    PAPADAKIS, N
    DYE, JL
    FEDERATION PROCEEDINGS, 1974, 33 (05) : 1319 - 1319
  • [42] COMPUTER INTERACTIVE STOPPED-FLOW SYSTEM FOR FAST REACTION-RATE MEASUREMENTS
    CROUCH, SR
    NOTZ, PK
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1976, 172 (SEP3): : 116 - 116
  • [43] STOPPED-FLOW CIRCULAR-DICHROISM - NEW FAST-KINETIC SYSTEM
    BAYLEY, PM
    ANSON, M
    BIOPOLYMERS, 1974, 13 (02) : 401 - 405
  • [44] INEXPENSIVE MICROCOMPUTER-BASED STOPPED-FLOW DATA ACQUISITION-SYSTEM
    TAYLOR, DG
    DEMAS, JN
    TAYLOR, RP
    ZENKOWICH, MJ
    BIOPHYSICAL JOURNAL, 1978, 24 (01) : 77 - 79
  • [45] FULLY AUTOMATED STOPPED-FLOW STUDIES WITH A HIERARCHICAL COMPUTER-CONTROLLED SYSTEM
    MIELING, GE
    TAYLOR, RW
    HARGIS, LG
    ENGLISH, J
    PARDUE, HL
    ANALYTICAL CHEMISTRY, 1976, 48 (12) : 1686 - 1693
  • [46] Separation and preconcentration system based on microextraction with ionic liquid for determination of copper in water and food samples by stopped-flow injection spectrofluorimetry
    Zeeb, Mohsen
    Ganjali, Mohammad Reza
    Norouzi, Parviz
    Kalaee, Mohamad Reza
    FOOD AND CHEMICAL TOXICOLOGY, 2011, 49 (05) : 1086 - 1091
  • [47] BIOREACTORS AND BIOMEMBRANES FOR BIOCHEMICAL OXYGEN-DEMAND ESTIMATION
    PRAET, E
    REUTER, V
    GAILLARD, T
    VASEL, JL
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1995, 14 (07) : 371 - 378
  • [48] Low-cost stopped-flow and freeze-quench device for double mixing
    Bujnowicz, Lukasz
    Pietras, Rafal
    Sarewicz, Marcin
    Osyczka, Artur
    HARDWAREX, 2023, 14
  • [49] STOPPED-FLOW KINETICS OF OXYGEN-UPTAKE AND RELEASE BY EMBRYONIC RED BLOOD-CELLS
    BRITTAIN, T
    SIMPSON, R
    BIOCHEMICAL JOURNAL, 1989, 261 (03) : 1009 - 1013
  • [50] STOPPED-FLOW, AIR-SEGMENTED CONTINUOUS-FLOW - KINETIC DETERMINATIONS OF GLUCOSE AND PHOSPHATE IN WINE AND SERUM SAMPLES
    HSIEH, YS
    CROUCH, SR
    ANALYTICA CHIMICA ACTA, 1993, 284 (01) : 159 - 166