Effect of ion bombardment on the Tl-response of both LiF (TLD-100) and a home-made LiF:Mg,Cu,P phosphors

被引:3
|
作者
AbdelHamid, HM
Hussein, MA
AbouZeid, HM
Morsy, SM
机构
[1] NATL CTR NUCL SAFETY & RADIAT CONTROL,NASR,CAIRO,EGYPT
[2] AIN SHAMS UNIV,GIRLS FAC,CAIRO,EGYPT
关键词
D O I
10.1016/S0168-583X(97)00415-1
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this article, a comparative dosimetric study is used on two types of phosphors; the standard LiF (TLD-100) and a home-made LIF : ME,Cu,P to show that ion beam bombardment may be a useful tool in the study and improvement of radiation sensitive materials. In the bombardment process, either oxygen ion (chemically active) or argon ion (chemically inert) was used, having energy of 4 keV and 3 flux of 21 x 10(13) ions cm(-2) s(-1) and the obtained results were compared with each other. It has been found that the sensitivity of the home-made LIF : Mg,Cu,P has got a maximum of similar to+40% when pre-treated for 5 min with argon ion beam. Meanwhile the sensitivity for the standard LiF (TLD-100) phosphor has got a maximum of similar to+20% when pre-treated with oxygen ion for 10 min. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:119 / 122
页数:4
相关论文
共 50 条
  • [22] THERMOLUMINESCENT RESPONSE OF LIF-MG,TI (TLD-100) AS A FUNCTION OF IRRADIATION TEMPERATURE FOR VARIOUS TYPES OF RADIATION
    KITIS, G
    CHARALAMBOUS, S
    TUYN, JWN
    RADIATION PROTECTION DOSIMETRY, 1992, 40 (02) : 117 - 122
  • [23] Investigation of the energy spectrum and dose response of optical absorption bands in 4N single crystal LiF and LiF:Mg,Ti (TLD-100)
    Biderman, S.
    Druzhyna, S.
    Reshes, G.
    Eliyahu, I.
    Oster, L.
    Horowitz, Y. S.
    RADIATION MEASUREMENTS, 2017, 106 : 30 - 34
  • [24] The effect of pre-irradiation heat treatment on the evaluated trapping parameters of LiF:Mg,Ti (TLD-100)
    Yazici, AN
    RADIATION PROTECTION DOSIMETRY, 1998, 80 (04) : 379 - 384
  • [25] The effect of cooling rate on the precision of measurement of glow peak 5 in the thermoluminescence of LiF:Mg,Ti (TLD-100)
    Bokobza, Yogev
    Biderman, Shlomo
    Horowitz, Yigal Shalom
    Oster, Leonid
    Eliyahu, Ilan
    Shapiro, Alex
    Nemirovsky, Dmitry
    Reshes, Galina
    Herman, Beny
    Einav, Hezy
    RADIATION PROTECTION DOSIMETRY, 2024, 200 (04) : 423 - 427
  • [26] Supralinear response of LiF:Mg,Ti (TLD-100) after exposure to 100 keV average energy X-rays
    Massillon-Jl, G.
    Avila, O.
    Brandan, M. E.
    RADIATION MEASUREMENTS, 2011, 46 (12) : 1357 - 1360
  • [27] Effect of dopants on the TL response of the new LiF:Mg,Cu,Ag material
    Yahyaabadi, A.
    Torkzadeh, F.
    Rezaei-Ochbelagh, D.
    Pooya, M. Hosseini
    RADIATION PHYSICS AND CHEMISTRY, 2018, 148 : 121 - 124
  • [28] TL response of pairs of 6LiF:Mg,Cu,Si/7LiF:Mg,Cu,Si and TLD-600/TLD-700 to 0.1-12 MeV neutrons
    Kim, J. L.
    Lee, J. I.
    Chang, I.
    Pradhan, A. S.
    Kim, S. I.
    Kim, B. H.
    RADIATION MEASUREMENTS, 2013, 56 : 223 - 227
  • [29] Anomalous behavior of LiF:Mg,Cu,P (TLD100H) irradiated with electron beams
    Triolo, A.
    Brai, M.
    Bartolotta, A.
    Marrale, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 568 (02): : 784 - 791
  • [30] Further studies in the reduction of residual in Harshaw TLD-100H (LiF:Mg,Cu,P)
    Ramlo, M.
    Moscovitch, M.
    Rotunda, J. E.
    RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 217 - 219