Effect of ion bombardment on the Tl-response of both LiF (TLD-100) and a home-made LiF:Mg,Cu,P phosphors

被引:3
|
作者
AbdelHamid, HM
Hussein, MA
AbouZeid, HM
Morsy, SM
机构
[1] NATL CTR NUCL SAFETY & RADIAT CONTROL,NASR,CAIRO,EGYPT
[2] AIN SHAMS UNIV,GIRLS FAC,CAIRO,EGYPT
关键词
D O I
10.1016/S0168-583X(97)00415-1
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this article, a comparative dosimetric study is used on two types of phosphors; the standard LiF (TLD-100) and a home-made LIF : ME,Cu,P to show that ion beam bombardment may be a useful tool in the study and improvement of radiation sensitive materials. In the bombardment process, either oxygen ion (chemically active) or argon ion (chemically inert) was used, having energy of 4 keV and 3 flux of 21 x 10(13) ions cm(-2) s(-1) and the obtained results were compared with each other. It has been found that the sensitivity of the home-made LIF : Mg,Cu,P has got a maximum of similar to+40% when pre-treated for 5 min with argon ion beam. Meanwhile the sensitivity for the standard LiF (TLD-100) phosphor has got a maximum of similar to+20% when pre-treated with oxygen ion for 10 min. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:119 / 122
页数:4
相关论文
共 50 条
  • [1] A comparative analysis of three thermoluminescent phosphors LiF:Mg,Ti (TLD-100), LiF:Mg,Cu and LiF:Mg,Cu,P
    Srivastava, JK
    Bhatt, BC
    Yoshimura, EM
    Okuno, E
    Sunta, CM
    RADIATION PROTECTION DOSIMETRY, 1996, 65 (1-4) : 191 - 194
  • [2] TL RESPONSE OF LIF TLD-100 AT HIGH IRRADIATION TEMPERATURES
    KATHURIA, SP
    SUNTA, CM
    PHYSICA STATUS SOLIDI A-APPLIED RESEARCH, 1982, 70 (02): : K125 - K128
  • [3] Influence of N+ ion bombardment an LiF (TLD-100) sensitivity
    AbdelHamid, HM
    Saad, HM
    Morsy, SM
    Hussein, MA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1997, 129 (01): : 73 - 76
  • [4] A comparative study on the susceptibility of LiF:Mg,Ti (TLD-100) and LiF:Mg,Cu,P (TLD-100H) to spurious signals in thermoluminescence dosimetry
    Al-Haj, Abdalla
    Lagarde, Charlie
    Mahyoub, Fareed
    RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 399 - 402
  • [5] Some dosimetric characteristics of the high temperature TL in LiF:Mg,Ti (TLD-100)
    Horowitz, Y. S.
    Oster, L.
    Datz, H.
    Margaliot, M.
    RADIATION MEASUREMENTS, 2008, 43 (2-6) : 203 - 207
  • [6] The saga of the thermoluminescence (TL) mechanisms and dosimetric characteristics of LiF:Mg,Ti (TLD-100)
    Horowitz, Y. S.
    Oster, L.
    Eliyahu, I
    JOURNAL OF LUMINESCENCE, 2019, 214
  • [7] Dose response of the individual peak for LiF:Mg,Ti (TLD-100) and LiF:Mg,Cu,P (GR-200A) TL materials at the photon energies of 30, 104, 1250 keV
    Cai, GG
    Bestion, N
    Wang, SS
    Shen, WX
    Delard, R
    Volpiliere, J
    Fesquet, J
    Gasiot, J
    RADIATION PROTECTION DOSIMETRY, 1996, 65 (1-4) : 213 - 215
  • [8] The thermoluminescence (TL) dose response of composite peak 5 in LiF:Mg,Ti (TLD-100): dependence on the order of kinetics
    Nemirovsky, Dimitry
    Oster, Leonid
    Reshes, Galina
    Biderman, Shlomo
    Bokobza, Yogev
    Sterenberg, Matan
    Eliyahu, Ilan
    Shapiro, Alexander
    Herman, Benny
    Horowitz, Yigal
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (06) : 498 - 508
  • [9] Dose response of F center optical absorption in LiF:Mg,Ti (TLD-100)
    Biderman, S.
    Eliyahu, I.
    Horowitz, Y. S.
    Oster, L.
    RADIATION MEASUREMENTS, 2014, 71 : 237 - 241
  • [10] The thermoluminescence dose-response and other characteristics of the high-temperature TL in LiF:Mg,Ti (TLD-100)
    Horowitz, Y. S.
    Oster, L.
    Datz, H.
    RADIATION PROTECTION DOSIMETRY, 2007, 124 (02) : 191 - 205