Various characteristics of the high-temperature thermoluminescence (HTTL) in the glow curve of LiF:Mg,Ti (TLD-100) are reviewed. The proposed applications of the HTTL to mixed-field radiation dosimetry are outlined with special emphasis on the question of the linearity/supralinearity of the HTTL dose-response at low dose levels from 2.5 to 250 mGy. Recent measurements of the HTTL dose-response using non-linear hot-gas heating and linear planchet heating are discussed in detail. It appears that a mild HTTL supralinearity of similar to 15-50% for each dose decade may be present, followed by an abrupt and rapid increase in the supralinearity > 250 mGy. However, difficulty in the estimation of background and the great variability in the protocols of measurement do not allow a definitive conclusion. There is much work to be done in the areas of protocol standardisation, materials selection, methods of data analysis and especially the details of background behaviour, and subtraction before the HTTL can become a reliable dosimetric tool.
引用
收藏
页码:191 / 205
页数:15
相关论文
共 50 条
  • [2] The saga of the thermoluminescence (TL) mechanisms and dosimetric characteristics of LiF:Mg,Ti (TLD-100)
    Horowitz, Y. S.
    Oster, L.
    Eliyahu, I
    JOURNAL OF LUMINESCENCE, 2019, 214
  • [3] Some dosimetric characteristics of the high temperature TL in LiF:Mg,Ti (TLD-100)
    Horowitz, Y. S.
    Oster, L.
    Datz, H.
    Margaliot, M.
    RADIATION MEASUREMENTS, 2008, 43 (2-6) : 203 - 207
  • [4] Characteristics of the high temperature thermoluminescence in LiF:Mg,Ti(TLD-100): The effects of batch history
    Datz, H.
    Horowitz, Y. S.
    Oster, L.
    Margaliot, M.
    RADIATION MEASUREMENTS, 2010, 45 (3-6) : 710 - 712
  • [5] The thermoluminescence (TL) dose response of composite peak 5 in LiF:Mg,Ti (TLD-100): dependence on the order of kinetics
    Nemirovsky, Dimitry
    Oster, Leonid
    Reshes, Galina
    Biderman, Shlomo
    Bokobza, Yogev
    Sterenberg, Matan
    Eliyahu, Ilan
    Shapiro, Alexander
    Herman, Benny
    Horowitz, Yigal
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (06) : 498 - 508
  • [6] Comments to the author's response to our letter on 'the thermoluminescence dose-response and other characteristics of the high-temperature TL in LiF: Mg, Ti (TLD-100)' by Y.S.!Horowitz, L.!Osterand H.!Datz
    German, U.
    Weinstein, M.
    Abraham, A.
    Alfassi, Z. B.
    RADIATION PROTECTION DOSIMETRY, 2008, 129 (04) : 495 - 497
  • [7] Influence of background subtraction protocol on the high temperature thermoluminescence in LiF:Mg,Ti (TLD-100)
    Datz, H.
    Horowitz, Y. S.
    Oster, L.
    Margaliot, M.
    RADIATION MEASUREMENTS, 2011, 46 (12) : 1440 - 1443
  • [8] Investigation of the emission spectra of LiF:Mg,Ti (TLD-100) during thermoluminescence
    Biderman, S
    Horowitz, Y
    Oster, L
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : 369 - 372
  • [9] Investigation of the emission spectra of LiF:Mg,Ti (TLD-100) during thermoluminescence
    Biderman, S
    Horowitz, Y
    Oster, L
    RADIATION PROTECTION DOSIMETRY, 2002, 100 (1-4) : 369 - 372
  • [10] EXPERIMENTAL INVESTIGATION OF THE 100 keV X-RAY DOSE RESPONSE OF THE HIGH-TEMPERATURE THERMOLUMINESCENCE IN LIF:MG,TI (TLD-100): THEORETICAL INTERPRETATION USING THE UNIFIED INTERACTION MODEL
    Livingstone, J.
    Horowitz, Y. S.
    Oster, L.
    Datz, H.
    Lerch, M.
    Rosenfeld, A.
    Horowitz, A.
    RADIATION PROTECTION DOSIMETRY, 2010, 138 (04) : 320 - 333