The thermoluminescence dose-response and other characteristics of the high-temperature TL in LiF:Mg,Ti (TLD-100)

被引:41
|
作者
Horowitz, Y. S. [1 ]
Oster, L. [2 ]
Datz, H.
机构
[1] Ben Gurion Univ Negev, Dept Phys, IL-84105 Beer Sheva, Israel
[2] Sami Shamoon Cool Engn, Phys Unit, Beer Sheva, Israel
关键词
TRACK-INTERACTION-MODEL; GLOW CURVE; HEATING RATE; THERMO-LUMINESCENCE; EMISSION-SPECTRA; LIF-TLD; DOSIMETRY; PEAKS; NEUTRON; SPACE;
D O I
10.1093/rpd/ncm241
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Various characteristics of the high-temperature thermoluminescence (HTTL) in the glow curve of LiF:Mg,Ti (TLD-100) are reviewed. The proposed applications of the HTTL to mixed-field radiation dosimetry are outlined with special emphasis on the question of the linearity/supralinearity of the HTTL dose-response at low dose levels from 2.5 to 250 mGy. Recent measurements of the HTTL dose-response using non-linear hot-gas heating and linear planchet heating are discussed in detail. It appears that a mild HTTL supralinearity of similar to 15-50% for each dose decade may be present, followed by an abrupt and rapid increase in the supralinearity > 250 mGy. However, difficulty in the estimation of background and the great variability in the protocols of measurement do not allow a definitive conclusion. There is much work to be done in the areas of protocol standardisation, materials selection, methods of data analysis and especially the details of background behaviour, and subtraction before the HTTL can become a reliable dosimetric tool.
引用
收藏
页码:191 / 205
页数:15
相关论文
共 50 条
  • [31] Characterization of TLD-100 (LiF:Mg,Ti) Microcube Energy Response in a Cylindrical Chamber Phantom
    Desai, V.
    Hammer, C.
    Kunugi, K.
    Culberson, W.
    DeWerd, L.
    MEDICAL PHYSICS, 2015, 42 (06) : 3371 - 3371
  • [32] Delocalized recombination kinetic modeling of the LiF:Mg,Ti (TLD-100) glow peak 5 TL system
    Weiss, D.
    Horowitz, Y. S.
    Oster, L.
    RADIATION MEASUREMENTS, 2008, 43 (2-6) : 254 - 258
  • [34] Dose response of the individual peak for LiF:Mg,Ti (TLD-100) and LiF:Mg,Cu,P (GR-200A) TL materials at the photon energies of 30, 104, 1250 keV
    Cai, GG
    Bestion, N
    Wang, SS
    Shen, WX
    Delard, R
    Volpiliere, J
    Fesquet, J
    Gasiot, J
    RADIATION PROTECTION DOSIMETRY, 1996, 65 (1-4) : 213 - 215
  • [35] OPTICAL BLEACHING OF DEFECT CENTERS IN TLD-100 (LIF-MG, TI)
    MERKLIN, JF
    NUCLEAR INSTRUMENTS & METHODS, 1978, 157 (03): : 519 - 523
  • [36] Defect structure of glow peak 1 in LiF:Mg,Ti (TLD-100)
    Yazici, A. Necmeddin
    Turkish Journal of Physics, 2002, 26 (06): : 473 - 481
  • [37] Dose-Response of TLD-100 in the Dose Range Useful for Hypofractionated Radiotherapy
    Liuzzi, Raffaele
    Piccolo, Consiglia
    D'Avino, Vittoria
    Clemente, Stefania
    Oliviero, Caterina
    Cella, Laura
    Pugliese, Mariagabriella
    DOSE-RESPONSE, 2020, 18 (01):
  • [38] Study of the effect of optical bleaching at selected photon energies on the optical absorption and thermoluminescence of LiF: Mg, Ti (TLD-100)
    Reshes, G.
    Druzhyna, S.
    Biderman, S.
    Eliyahu, I.
    Oster, L.
    Horowitz, Y. S.
    RADIATION MEASUREMENTS, 2017, 106 : 26 - 29
  • [39] HIGH AMBIENT-TEMPERATURE EFFECTS IN LIF TLD-100
    DELGADO, A
    ROS, JMG
    MUNIZ, JL
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1991, 24 (07) : 1126 - 1130
  • [40] TL DOSE-RESPONSE AND THE RELATIVE TL PRODUCTION EFFICIENCY OF LIF-TLD
    KALEFEZRA, J
    HOROWITZ, YS
    PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (04): : 766 - 766