Patient Outcomes Following Implantation of Modular Neck Hip Prostheses in Primary Total Hip Arthroplasty

被引:2
|
作者
Borden, Robert [1 ]
Pour, Aidin Eslam [1 ]
Murayama, Takayuki [1 ]
Blaha, J. David [1 ]
机构
[1] Univ Michigan, 1500 E Med Ctr Dr, Ann Arbor, MI 48109 USA
关键词
adverse tissue response to metal debris; corrosion; modular neck femoral stem; pseudotumor; total hip arthroplasty; SYSTEM;
D O I
10.1520/STP159120140151
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Bimodular femoral neck components were introduced to optimize implant size and offset. Failures have been reported and long-term outcome of modular necks must be assessed. The purpose of this study was to investigate the results of a series of modular neck implants and catalog the causes of failure of them. Our series included 277 hips (244 patients) with Profemur-E and Profemur-Z femoral stems (Wright Medical Technology Inc., now MicroPort Orthopaedics Arlington, TN). Data for this cohort of patients included demographics, implant dimensions, and the type of articular surface. Correlation of these variables with failure was analyzed to estimate the effect of each on survivorship. Implant failure was defined as cases requiring revision surgery. Seven cases were revised for implant neck fracture (2.5 %), and four were revised for adverse local tissue reactions (ALTR; 1.4 %). Seven required replacement of fractured neck with a cobalt-chromium (CoCr) modular neck. Regression analysis showed that a 1-unit increase in body mass index (BMI) increased the probability of neck fracture by a factor of 1.19 and every 4-mm increase in head diameter increased the chance of neck fracture by a factor of 3.2. Increase in neck offset is associated with a 1.83 times increased likelihood of neck fracture. Co levels correlated positively with neck fracture, and titanium levels correlated positively with gas in the joint. Cr and titanium levels were significantly higher in patients who had aseptic revision surgery. These data suggest that failure of modular neck junctions may be potentiated by higher BMI, greater offset, and larger head diameters. It is suspected that these factors contribute to modular neck failure by creating a stronger moment arm about the neck's insertion into the stem. A lower level of titanium than 7 ng/dL might be considered as the threshold. These data may help identify a set of factors that contraindicate the use of modular neck junctions.
引用
收藏
页码:17 / 25
页数:9
相关论文
共 50 条
  • [31] Modular neck and ceramic on ceramic coupling in revision total hip arthroplasty
    Pignatti, G.
    Stagni, C.
    Dallari, D.
    Bochicchio, V.
    Raimondi, A.
    Giunti, A.
    BIOCERAMICS AND ALTERNATIVE BEARINGS IN JOINT ARTHROPLASTY, 2006, : 145 - +
  • [32] Metal release and corrosion effects of modular neck total hip arthroplasty
    Kretzer, J. Philippe
    Jakubowitz, Eike
    Krachler, Michael
    Thomsen, Marc
    Heisel, Christian
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (06) : 1531 - 1536
  • [33] Metal release and corrosion effects of modular neck total hip arthroplasty
    J. Philippe Kretzer
    Eike Jakubowitz
    Michael Krachler
    Marc Thomsen
    Christian Heisel
    International Orthopaedics, 2009, 33 : 1531 - 1536
  • [34] Venous thromboembolism following primary total hip arthroplasty
    Hitos, K.
    Fletcher, J. P.
    INTERNATIONAL ANGIOLOGY, 2009, 28 (03) : 215 - 221
  • [35] OCCUPATIONAL OUTCOMES FOLLOWING TOTAL HIP-ARTHROPLASTY
    NEVITT, MC
    MASEM, MA
    EPSTEIN, WV
    CLINICAL RESEARCH, 1981, 29 (02): : A487 - A487
  • [36] Foot drop following primary total hip arthroplasty
    O'Brien, Seamus
    Gallagher, Nicola
    Spence, David
    Bennett, Damien
    Dennison, Janice
    Beverland, David E.
    HIP INTERNATIONAL, 2020, 30 (02) : 135 - 140
  • [37] Early Death Following Primary Total Hip Arthroplasty
    Jones, Mark D.
    Parry, Michael C.
    Whitehouse, Michael R.
    Blom, Ashley W.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (08): : 1625 - 1628
  • [38] Clinical Outcomes of Conical Hip Prosthesis Used In Primary Total Hip Arthroplasty
    Melnic, Akhil Katakam
    Hanson, George
    Melnic, Christopher M.
    Bedair, Hany S.
    SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2021, 38
  • [39] The outcomes of hip resurfacing compared to standard primary total hip arthroplasty in Men
    Issa, Kimona
    Palich, Amanda
    Tatevossian, Tiffany
    Kapadia, Bhaveen H.
    Naziri, Qais
    Mont, Michael A.
    BMC MUSCULOSKELETAL DISORDERS, 2013, 14
  • [40] The outcomes of hip resurfacing compared to standard primary total hip arthroplasty in Men
    Kimona Issa
    Amanda Palich
    Tiffany Tatevossian
    Bhaveen H Kapadia
    Qais Naziri
    Michael A Mont
    BMC Musculoskeletal Disorders, 14