Metal release and corrosion effects of modular neck total hip arthroplasty

被引:0
|
作者
J. Philippe Kretzer
Eike Jakubowitz
Michael Krachler
Marc Thomsen
Christian Heisel
机构
[1] University of Heidelberg,Laboratory of Biomechanics and Implant Research, Department of Orthopaedics
[2] University of Heidelberg,Institute of Earth Sciences
[3] German Red Cross Hospital,undefined
[4] ARCUS Kliniken Pforzheim,undefined
[5] Department of Orthopaedics and Traumatology,undefined
来源
关键词
Surface Roughness; Titanium Particle; Titanium Concentration; Modular Neck; Periprosthetic Bone Loss;
D O I
暂无
中图分类号
学科分类号
摘要
Modular neck implants are an attractive treatment tool in total hip replacement. Concerns remain about the mechanical stability and metal ion release caused by the modular connection. Five different implant designs were investigated in an experimental set-up. In vivo conditions were simulated and the long-term titanium release was measured. Finally, the modular connections were inspected for corrosion processes and signs of fretting. No mechanical failure or excessive corrosion could be identified for the implants tested. The titanium releases measured were extremely low compared to in vivo and in vitro studies and were not in a critical range.
引用
收藏
页码:1531 / 1536
页数:5
相关论文
共 50 条
  • [1] Metal release and corrosion effects of modular neck total hip arthroplasty
    Kretzer, J. Philippe
    Jakubowitz, Eike
    Krachler, Michael
    Thomsen, Marc
    Heisel, Christian
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (06) : 1531 - 1536
  • [2] Correlation of Corrosion and Biomechanics in the Retrieval of a Single Modular Neck Total Hip Arthroplasty Design Modular Neck Total Hip Arthroplasty System
    Lanting, Brent A.
    Teeter, Matthew G.
    Vasarhelyi, Edward M.
    Ivanov, Todor G.
    Howard, James L.
    Naudie, Douglas D. R.
    JOURNAL OF ARTHROPLASTY, 2015, 30 (01): : 135 - 140
  • [3] Fretting and Corrosion in Modular-Neck Total Hip Arthroplasty Femoral Stems
    Molloy, Dennis O.
    Munir, Selin
    Jack, Christopher M.
    Cross, Michael B.
    Walter, William L.
    Walter, William K., Sr.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2014, 96A (06): : 488 - 493
  • [4] The Local Effects of Metal Corrosion in Total Hip Arthroplasty
    Cooper, H. John
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2014, 45 (01) : 9 - +
  • [5] Modular neck total hip arthroplasty - a perfect storm
    Humadi, Ali
    Jamieson, Richard
    Chao, Tat
    Tacey, Mark
    Khoury, Elie
    HIP INTERNATIONAL, 2016, 26 (02) : 128 - 131
  • [6] Long-Term Outcome of Metal-on-Metal Total Hip Arthroplasty with Modular Neck Stem
    Wakabayashi, Hiroki
    Hasegawa, Masahiro
    Naito, Yohei
    Tone, Shine
    Sudo, Akihiro
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (06)
  • [7] Modular neck stems in total hip arthroplasty: current concepts
    Solarino, Giuseppe
    Vicenti, Giovanni
    Carrozzo, Massimiliano
    Ottaviani, Guglielmo
    Moretti, Biagio
    Zagra, Luigi
    EFORT OPEN REVIEWS, 2021, 6 (09) : 751 - 758
  • [8] Midterm Outcome of Modular Metal-on-Metal Total Hip Arthroplasty
    Wakabayashi, Hiroki
    Hasegawa, Masahiro
    Yamaguchi, Toshio
    Naito, Yohei
    Sudo, Akihiro
    ARTHRITIS & RHEUMATOLOGY, 2016, 68
  • [9] Metal on Metal Total Hip Arthroplasty Using Modular Acetabular Shells
    Liudahl, Adam A.
    Liu, Steve S.
    Goetz, Devon D.
    Mahoney, Craig R.
    Callaghan, John J.
    JOURNAL OF ARTHROPLASTY, 2013, 28 (05): : 867 - 871
  • [10] Modular neck and ceramic on ceramic coupling in revision total hip arthroplasty
    Pignatti, G.
    Stagni, C.
    Dallari, D.
    Bochicchio, V.
    Raimondi, A.
    Giunti, A.
    BIOCERAMICS AND ALTERNATIVE BEARINGS IN JOINT ARTHROPLASTY, 2006, : 145 - +