A new design for a compact centrifugal blood pump with a magnetically levitated rotor

被引:33
|
作者
Asama, J
Shinshi, T
Hoshi, H
Takatani, S
Shimokohbe, A
机构
[1] Tokyo Inst Technol, Precis & Intelligence Lab, Midori Ku, Yokohama, Kanagawa 2268503, Japan
[2] Tokyo Inst Technol, Interdisciplinaty Grad Sch Sci & Engn, Yokohama, Kanagawa 2268503, Japan
[3] Tokyo Med & Dent Univ, Inst Biomat & Bioengn, Tokyo, Japan
关键词
D O I
10.1097/01.MAT.0000144364.62671.5A
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A compact centrifugal blood pump has been developed using a radial magnetic bearing with a two-degree of freedom active control. The proposed magnetic bearing exhibits high stiffness, even in passively controlled directions, and low power consumption because a permanent magnet, incorporated with the rotor, suspends its weight. The rotor is driven by a Lorentz force type of built-in motor, avoiding mechanical friction and material wear. The built-in motor is designed to generate only rotational torque, without radial and axial attractive forces on the rotor, leading to low power consumption by the magnetic bearing. The fabricated centrifugal pump measured 65 mm in diameter and 45 mm in height and weighed 0.36 kg. In the closed loop circuit filled with water, the pump provided a flow rate of 4.5 L/min at 2,400 rpm against a pressure head of 100 mm Hg. Total power consumption at that point was 18 W, including 2 W required for magnetic levitation, with a total efficiency of 5.7%. The experimental results showed that the design of the compact magnetic bearing was feasible and effective for use in a centrifugal blood pump.
引用
收藏
页码:550 / 556
页数:7
相关论文
共 50 条
  • [21] CENTRIFUGAL BLOOD PUMP WITH A MAGNETICALLY SUSPENDED IMPELLER
    AKAMATSU, T
    NAKAZEKI, T
    ITOH, H
    [J]. ARTIFICIAL ORGANS, 1992, 16 (03) : 305 - 308
  • [22] A Novel Design of Spiral Groove Bearing in a Hydrodynamically Levitated Centrifugal Rotary Blood Pump
    Han, Qing
    Zou, Jun
    Ruan, Xiaodong
    Fu, Xin
    Yang, Huayong
    [J]. ARTIFICIAL ORGANS, 2012, 36 (08) : 739 - 746
  • [23] Effects of Eccentric Impeller Position on Radial Passive Stability in a Magnetically Levitated Centrifugal Blood Pump with a Double Volute
    Shida, Shuya
    Masuzawa, Toru
    Osa, Masahiro
    Sato, Ryota
    [J]. ADVANCED BIOMEDICAL ENGINEERING, 2018, 7 : 63 - 71
  • [24] SEAL-LESS CENTRIFUGAL BLOOD PUMP WITH MAGNETICALLY SUSPENDED ROTOR - ROT-A-FLOT
    MENDLER, N
    PODECHTL, F
    FEIL, G
    HILTMANN, P
    SEBENING, F
    [J]. ARTIFICIAL ORGANS, 1995, 19 (07) : 620 - 624
  • [25] Flow rate estimation of a centrifugal blood pump using the passively stabilized eccentric position of a magnetically levitated impeller
    Shidai, Shuya
    Masuzawa, Toru
    Osa, Masahiro
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2019, 42 (06): : 291 - 298
  • [26] Channel Rotor Calculation for a Centrifugal Blood Pump
    Kuleshov, A. P.
    Itkin, G. P.
    [J]. BIOMEDICAL ENGINEERING-MEDITSINSKAYA TEKNIKA, 2019, 52 (05): : 311 - 315
  • [27] Channel Rotor Calculation for a Centrifugal Blood Pump
    A. P. Kuleshov
    G. P. Itkin
    [J]. Biomedical Engineering, 2019, 52 : 311 - 315
  • [28] A COMPACT CENTRIFUGAL BLOOD PUMP FOR EXTRACORPOREAL-CIRCULATION - DESIGN AND PERFORMANCE
    TANAKA, S
    YAMAMOTO, S
    YAMAKOSHI, K
    KAMIYA, A
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1987, 109 (03): : 272 - 278
  • [29] An Integrated Centrifugal Pump Rotor Design Course
    Adair, Desmond
    Jaeger, Martin
    [J]. 2014 4th Interdisciplinary Engineering Design Education Conference (IEDEC), 2014, : 6 - 11
  • [30] Less-invasive tools and technique for fully magnetically levitated centrifugal pump implantation
    Netuka, Ivan
    Konarik, Miroslav
    Pokorny, Martin
    Ivak, Peter
    Maly, Jiri
    Szarszoi, Ondrej
    [J]. ANNALS OF CARDIOTHORACIC SURGERY, 2021, 10 (02) : 289 - 291