SEAL-LESS CENTRIFUGAL BLOOD PUMP WITH MAGNETICALLY SUSPENDED ROTOR - ROT-A-FLOT

被引:46
|
作者
MENDLER, N
PODECHTL, F
FEIL, G
HILTMANN, P
SEBENING, F
机构
[1] Department of Cardiovascular Surgery, German Heart Center, Munich
关键词
CENTRIFUGAL BLOOD PUMP; SEAL-LESS PUMP; MAGNETIC SUSPENSION; EFFICIENCY OF BLOOD PUMP; COMPARISON OF BLOOD PUMPS;
D O I
10.1111/j.1525-1594.1995.tb02391.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Limitations of current centrifugal blood pumps are related to heat generation of bearings and leakage of seals, to dead water zones, and to poor efficiency. A new concept is proposed in this paper to ameliorate these problems based on a miniaturized magnetic drive, and a prototype is introduced. The pump rotor is suspended and driven by a radial permanent magnetic field that stabilizes the impeller in 4 of the 6 spatial degrees of freedom and allows it to be top-spun on a single blood-flushed pivot bearing with minimal load and friction. A shrouded impeller with an open center and 4 logarithmically curved channels is run inside a cone-and-plate-type housing with a spiral volute chamber. In vitro testing was performed comparing this design with the BioMedicus, St. Jude, and Sarns pumps. The prototype is demonstrated to have the smallest internal volume (35 ml), surface (190 gcm), and passage time (0.5 s at 4 L/min), as well as the highest hydraulic efficiency (up to 0.4) of all devices studied.
引用
收藏
页码:620 / 624
页数:5
相关论文
共 50 条
  • [1] Seal-less centrifugal blood pump and magnetically suspended rotor: Rot-a-flot (vol 19, pg 621, 1995)
    Mendler, N
    Podechtl, F
    Feil, G
    Hiltmann, P
    Sebening, F
    [J]. ARTIFICIAL ORGANS, 1996, 20 (02) : 195 - 195
  • [2] CENTRIFUGAL BLOOD PUMP WITH A MAGNETICALLY SUSPENDED IMPELLER
    AKAMATSU, T
    NAKAZEKI, T
    ITOH, H
    [J]. ARTIFICIAL ORGANS, 1992, 16 (03) : 305 - 308
  • [3] AN ADDITION TO THE SEAL-LESS PUMP PAPER
    GAMP, SH
    [J]. CHEMICAL ENGINEERING PROGRESS, 1954, 50 (11) : A8 - A8
  • [4] AN IMPLANTABLE SEAL-LESS CENTRIFUGAL PUMP WITH INTEGRATED DOUBLE-DISK MOTOR
    SCHIMA, H
    SCHMALLEGGER, H
    HUBER, L
    BIRGMANN, I
    REINDL, C
    SCHMIDT, C
    ROSCHAL, K
    WIESELTHALER, G
    TRUBEL, W
    LOSERT, U
    WOLNER, E
    [J]. ARTIFICIAL ORGANS, 1995, 19 (07) : 639 - 643
  • [5] A magnetically suspended and hydrostatically stabilized centrifugal blood pump
    Hart, RM
    Filipenco, VG
    Kung, RTV
    [J]. ARTIFICIAL ORGANS, 1996, 20 (06) : 591 - 596
  • [6] A SEAL-LESS CENTRIFUGAL PUMP DESIGN FOR THE ELIMINATION OF HEAT-INDUCED THROMBUS FORMATION
    BELENGER, J
    JEANJACQUOT, A
    KNIGHT, CJ
    [J]. ARTIFICIAL ORGANS, 1981, 5 (02) : 193 - 193
  • [7] A SEAL-LESS CENTRIFUGAL PUMP (BAYLOR GYRO PUMP) FOR APPLICATION TO LONG-TERM CIRCULATORY SUPPORT
    MINATO, N
    SAKUMA, I
    SASAKI, T
    SHIONO, M
    OHARA, Y
    TAKATANI, S
    NOON, GP
    NOSE, Y
    [J]. ARTIFICIAL ORGANS, 1993, 17 (01) : 36 - 42
  • [8] BAYLOR GYRO PUMP - A COMPLETELY SEAL-LESS CENTRIFUGAL PUMP AIMING FOR LONG-TERM CIRCULATORY SUPPORT
    OHARA, Y
    SAKUMA, I
    MAKINOUCHI, K
    DAMM, G
    GLUECK, J
    MIZUGUCHI, K
    NAITO, K
    TASAI, K
    ORIME, Y
    TAKATANI, S
    NOON, GP
    NOSE, Y
    [J]. ARTIFICIAL ORGANS, 1993, 17 (07) : 599 - 604
  • [9] RECENT STUDIES OF THE CENTRIFUGAL BLOOD PUMP WITH A MAGNETICALLY SUSPENDED IMPELLER
    AKAMATSU, T
    TSUKIYA, T
    NISHIMURA, K
    PARK, CH
    NAKAZEKI, T
    [J]. ARTIFICIAL ORGANS, 1995, 19 (07) : 631 - 634
  • [10] Performance and unsteady characteristics of magnetically suspended centrifugal blood pump
    Yoshino, Y
    Akamatsu, T
    [J]. JSME INTERNATIONAL JOURNAL SERIES B-FLUIDS AND THERMAL ENGINEERING, 1997, 40 (01) : 114 - 120