Ambu AuraOnce versus i-gel laryngeal mask airway in infants and children undergoing surgical procedures A randomized controlled trial

被引:9
|
作者
Alzahem, Abdulrahman M. [1 ]
Aqil, Mansoor [2 ]
Alzahrani, Tariq A. [2 ]
Aljazaeri, Ayman H. [1 ]
机构
[1] King Saud Univ, Coll Med, King Saud Univ Med City, Dept Pediat Surg, Riyadh, Saudi Arabia
[2] King Saud Univ, Coll Med, King Saud Univ Med City, Dept Anesthesiol, Riyadh, Saudi Arabia
关键词
SUPRAGLOTTIC AIRWAY; ANESTHETIZED PATIENTS; INTRAOCULAR-PRESSURE; VENTILATED CHILDREN; PEDIATRIC-PATIENTS; COHORT EVALUATION; SCORING SYSTEM; INSERTION; LMA-CLASSIC(TM); PERFORMANCE;
D O I
10.15537/smj.2017.5.17960
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To compare the efficacy and performance of the pediatric Ambu AuraOnce (Ambu AO) mask (Ambu, Copenhagen, Denmark) and i-gel mask (Intersurgical Ltd., Wokingham, United Kingdom). Methods: From May 2015 to September 2016, 112 patients, 0-14 years old, underwent elective surgery at a tertiary university hospital (Riyadh, Saudi Arabia). They were randomly assigned to the Ambu AO or i-gel group. Three groups underwent a subgroup analysis: <= 5 kg (group 1), 5.1-10.0 kg (group 2), and >10 kg (group 3). Results: The oropharyngeal leak pressure was significantly higher for the i-gel (25.4 +/- 4.1 cm H2O) than for the Ambu AO (22.5 +/- 3.9 cm H2O, p<0.001). The Ambu AO had a slightly higher ease of insertion compared to the i-gel (100% versus 94%, p=0.08) and required less manipulation (2% versus 11%, p=0.07). The Ambu AO and i-gel showed non-significant differences in performance between weight groups. There were statistically significant differences for higher leak pressure in group 2 (p=0.01) and group 3 (p=0.002) in favor of the i-gel, and for less manipulation in the Ambu AO in group 1 (p=0.04). Fiberoptic viewing was superior in group 2 for the i-gel (p=0.03) and in group 3 for the Ambu AO (p=0.02). Conclusion: Both devices demonstrated equally good performance with low morbidity. The Ambu AO had a statistical tendency towards easier insertion and less manipulation. Confirming this finding will require large scale trials.
引用
收藏
页码:482 / 490
页数:9
相关论文
共 50 条
  • [31] Lubrication of the i-gel supraglottic airway and the classic laryngeal mask airway reply
    Wilkes, A. R.
    Janakiraman, C.
    Goodwin, N.
    Stacey, M. R.
    ANAESTHESIA, 2010, 65 (01) : 89 - 89
  • [32] Observation of ventilation effects of I-gel™, Supreme™ and Ambu AuraOnce™ with respiratory dynamics monitoring in small children
    Zhiqing Gu
    Quanying Jin
    Junjun Liu
    Lianhua Chen
    Journal of Clinical Monitoring and Computing, 2017, 31 : 1035 - 1041
  • [33] Comparison between i-gel airway an the proseal laryngeal mask airway in pediatric patients undergoing general anesthesia
    Acharya, R.
    Dave, N. M.
    PEDIATRIC ANESTHESIA AND CRITICAL CARE JOURNAL, 2016, 4 (02): : 97 - 102
  • [34] Comparison of the i-gel™ with the AuraGain™ laryngeal mask airways in patients with a simulated cervical immobilization: a randomized controlled trial
    Hur, Min
    Choi, Seungeun
    Row, Hyung S.
    Kim, Tae K.
    MINERVA ANESTESIOLOGICA, 2020, 86 (07) : 727 - 735
  • [35] Are nurses able to perform blind intubation? Randomized comparison of I-gel and laryngeal mask airway
    Ladny, Jerzy R.
    Bielski, Karol
    Szarpak, Lukasz
    Cieciel, Michal
    Konski, Roman
    Smereka, Jacek
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2017, 35 (05): : 786 - 787
  • [36] Comparative evaluation of Ambu Aura-i and Fastrach™ intubating laryngeal mask airway for tracheal intubation: A randomized controlled trial
    Anand, Lakesh
    Singh, Manpreet
    Kapoor, Dheeraj
    Singh, Anjali
    JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2019, 35 (01) : 70 - 75
  • [37] Randomized crossover comparison of the laryngeal mask airway classic with i-gel laryngeal mask airway in the management of difficult airway in post burn neck contracture patients
    Singh, Jeevan
    Yadav, Manohar Kumar
    Marahatta, Sujan Babu
    Shrestha, Bikash Lal
    INDIAN JOURNAL OF ANAESTHESIA, 2012, 56 (04) : 348 - 352
  • [38] The perfomance of the pediatric-sized i-gel™ compared with the Ambu Aura Once™ laryngeal mask in anesthetized and ventilated children
    Kleine-Brueggeney, M.
    Theiler, L.
    Urwyler, N.
    Stucki, F.
    Greif, R.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (01) : 156 - 156
  • [39] The performance of the pediatric-sized i-gel™ compared with the Ambu Aura Once™ Laryngeal Mask in anesthetized and ventilated children
    Seiler, Stefan
    Stucki, Franziska
    Theiler, Lorenz
    Kleine-Brueggeney, Maren
    Luepold, Barbara
    Urwyler, Natalie
    Greif, Robert
    SWISS MEDICAL WEEKLY, 2010, 140 : 6S - 6S
  • [40] A comparison of i-gel (TM) and Laryngeal Mask Airway Supreme (TM) during general anesthesia in infants
    Lee, Yoon Chan
    Yoon, Kyoung Seop
    Park, Sang Yoong
    Choi, So Ron
    Chung, Chan Jong
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2018, 71 (01) : 37 - 42